• Title/Summary/Keyword: depth radiation

Search Result 637, Processing Time 0.027 seconds

Paper Operration room nurses Experience in Using Radiation Suegery: Phenomenological Research (수술실 간호사의 방사선 노출 경험: 현상학적 연구)

  • Yun, Jae-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.426-438
    • /
    • 2020
  • This study aimed to identify the components of the nurses' exposure experiences and clarify the semantic structure of nurses by analyzing the participants' experiences of exposure to radiation. The participants in this study were nine nurses who worked for at least six months in the operating room of a City General Hospital. The data were collected using in-depth interviews and analyzed using the phenomenological method by Giorgi's (2004). As a result, six components were derived: "worrying about the disease by repeated radiation exposures", "exhausting physically and mentally," "trying to protect themselves against radiation exposure", "feeling of internal confusion and conflict", "demanding improvement of work environment", and "accepting and adapting to reality". In conclusion, nurses participating in radiation exposure surgery are concerned about the possibility of disease, experience physical and mental fatigue, and then consider changing their occupation. On the other hand, they try to accept and adapt to reality by considering the possibility of a job change or trying to protect themselves from the harsh environment. To develop a radiologically safe environment, systematic and effective resolutions must be secured at the organizational level.

Effect of Scatter ray in Outside Telecobalt-60 Field Size (코발트-60 조사야 밖의 장기에 미치는 2차선의 영향)

  • Kim, You-Hyun;Kim, Young-Whan
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.65-71
    • /
    • 1988
  • Radiation dose outside the radiotherapy treatment field can be significant and therefore is of clinical interest estimating organ dose. We have made measurements of dose at distances up to 70 cm from the central axis of $5{\times}5$, $10{\times}10$, $15{\times}15$, and $25{\times}25$ cm radiation fields of Co-60 ${\gamma}-ray$, at 5 cm depth in water. Contributions to the total secondary radiation dose from water scatter, machine (collimator) scatter and leakage radiation have been seperated. We have found that the component of dose from water scatter can be described by simple exponential function of distance from the central axis of the radiation field for all field sizes. Machine scatter contributes 20 to 60% of the total secondary dose depending on field size and distance from the field. Leakage radiation contributes very little dose, but becomes the dominant componant at distance beyond 40 cm from the central axis. Then, wedges can cause a factor 2 to 3 increase in dose at any point outside the field compared with the dose when no wedge is used. Adding blocks to a treatment field can cause an increase in dose at points outside the field, but the effect is much smaller than the effect of a wedge. From the results of these measurements, doses to selected organs outside the field for specified treatment geometries were estimated, and the potential for reducing these organ doses by additional shielding was assessed.

  • PDF

Future Changes in Surface Radiation and Cloud Amount over East Asia under RCP Scenarios (RCP 시나리오에 따른 미래 동아시아 지표복사에너지와 운량 변화 전망)

  • Lee, Cheol;Boo, Kyung-On;Shim, Sungbo;Byun, Youngwha
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.433-442
    • /
    • 2016
  • In this study, we examine future changes in surface radiation associated with cloud amount and aerosol emission over East Asia. Data in this study is HadGEM2-CC (Hadley Centre Global Environmental Model version 2, Carbon Cycle) simulations of the Representative Concentration Pathways (RCPs) 2.6/4.5/8.5. Results show that temperature and precipitation increase with rising of the atmosphere $CO_2$. At the end of $21^{st}$ century (2070~2099) relative to the end of $20^{st}$ century (1981~2005), changes in temperature and precipitation rate are expected to increase by $+1.85^{\circ}C/+6.6%$ for RCP2.6, $+3.09^{\circ}C/+8.5%$ for RCP4.5, $+5.49^{\circ}C/10%$ for RCP8.5. The warming results from increasing Net Down Surface Long Wave Radiation Flux (LW) and Net Down Surface Short Wave Radiation Flux (SW) as well. SW change increases mainly from reduced total Aerosol Optical Depth (AOD) and low-level cloud amount. LW change is associated with increasing of atmospheric $CO_2$ and total cloud amount, since increasing cloud amounts are related to absorb LW radiation and remit the energy toward the surface. The enhancement of precipitation is attributed by increasing of high-level cloud amount. Such climate conditions are favorable for vegetation growth and extension. Expansion of C3 grass and shrub is distinct over East Asia, inducing large latent heat flux increment.

Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus (Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성)

  • Kim, Sung Joon;Lee, Seoung Jun;Moon, Su Ho;Seol, Ki Ho;Lee, Jeong Eun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.225-232
    • /
    • 2014
  • We evaluated the effect of scatter on a build-up region based on the measured percent depth dose (PDD) of high-energy photon beams that penetrated a handmade build-up modifier (BM) as a substitute of bolus. BM scatter factors ($S_{BM}$) were calculated based on the PDDs of photon beams that penetrated through the BM. The calculated $S_{BM}$ values were normalized to 1 at the square field side (SFS) of 30 mm without a BM. For the largest SFS (200 mm), the SBM values for a 6-MV beam were 1.331, 1.519, 1.598, 1.641, and 1.657 for the corresponding BM thickness values. For a 10-MV beam, the $S_{BM}$ values were 1.384, 1.662, 1.825, 1.913, and 2.001 for the corresponding BM thickness values. The BM yielded 76% of the bolus efficiency. We expect BM to become useful devices for deep-set patient body parts to which it is difficult to apply a bolus.

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

Peripheral Dose Distributions of Clinical Photon Beams (광자선에 의한 민조사면 경계영역의 선량분포)

  • 김진기;김정수;권형철
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The region, near the edge of a radiation beam, where the dose changes rapidly according to the distance from the beam axis is known as the penumbra. There is a sharp dose gradient zone even in megavoltage photon beams due to source size, collimator, lead alloy block, other accessories, and internal scatter ray. We investigate dosimetric characteristics on penumbra regions of a standard collimator and compare to those of theoritical model for the optimal use of the system in radiotherapy. Peripheral dose distribution of 6 W Photon beams represents penumbral forming function as the depth. Also we have discussed that the peripheral dose distribution of clinical photon beams, differences between calculation dose use of emperical penumbral forming function and measurements in penumbral region. Predictions by emperical penumbral forming functions are compared with measurements in 3-dimensional water phantom and it is shown that the method is capable of reproduceing the measured peripheral dose values usually to within the statistical uncertainties of the data. The semiconductor detector and ion chamber were positioned at a dmax depth, 5cm depth, 10cm depth, and its specific ratio was determined using a scanning data. The effective penumbra, the distance from 80% to 20% isodose lines were analyzed as a function of the distance. The extent of penumbra will also expand with depth increase. Difference of measurement value and model functions value according to character of the detector show small error in dose distribution of the peripheral dose.

  • PDF

Numerical Analysis of Hydrodynamic Forces on a Floating Body in Two-layer Fluids (밀도가 상이한 두 유체층에서 부유체 동유체력 특성의 수치적 해석)

  • Kim, Mi-Geun;Koo, Weon-Cheol
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.369-376
    • /
    • 2010
  • In this study, a radiation and a diffraction problems of a floating body in two-layer fluids were solved by the Numerical Wave Tank(NWT) technique in the frequency domain. In two-layer fluids, two different wave modes exist and the hydrodynamic coefficients can be obtained separately for each mode. The two-domain Boundary Element Method(BEM) in the potential fluid using the whole-domain matrix scheme was used to investigate the characteristics of wave forces, added mass and damping coefficients. The effects of the ratio of density and water depth in the lower domain were also evaluated and compared with given references.

Dosimetric characteristics of an independent collimator system using measurements performed quarter fields. (Independent jaw를 이용한 비대칭조사면의 선량분포에 관한 연구)

  • Kim Geon O;Jeong Se Yeong;Kim Yeong Beom;Gwon Yeong Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.109-116
    • /
    • 2002
  • The mordem linear accelerators are equipped with X-ray collimators that can be moved independently to allow asymmetric fields with field centers positioned away from the true central axis of the beam. We have studied the dosimetric of an independent collimator system using measurements performed quarter fields. The field size factors for asymmetric fields are compared to those for symmetric fields. Dosimetric measurements include portent depth don, beam penumbra and shape of isodose curves for symmetric and quarter fields.

  • PDF

A Study on the Numerical Model of Wave Induced Current around Nearshore Structure (연안역 구조물 주위에서의 해빈류의 수치해석에 관한 연구)

  • 민병형;이상화;김인철
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.55-63
    • /
    • 1991
  • This study is to predict accurately the wave induced current accuring by the radiation stress which acts as the driving force around Nearshore structure. For the wave induced current, the depth integrated and time averaged governing equation of an unsteady nonlinear form is derived from the continuity and momentum equation of an incompressible fluid. Numerical solutions are obtained by a finite difference method for the governing equation. In the vicinity of a structure, computed flow patterns show good agreement with the hydraulic experimental data. The numerical results obtained by neglecting the convective term show a large change of alongshore and offshore current.

  • PDF