• Title/Summary/Keyword: dependency test

Search Result 380, Processing Time 0.025 seconds

PHASE-B PRE-SIMULATION USING BORON AND GADOLINIUM AS POISON IN THE MODERATOR SYSTEM FOR WOLSONG-1

  • Kim, Sung-Min;Kim, Hyeong-Taek;Donnelly, Jim;Marleau, Guy
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.551-560
    • /
    • 2012
  • The Wolsong-1 (W-1) Phase-B pre-simulations were carried out in preparation for tests to be conducted for the restart of the reactor after a major refurbishment project that included replacement of the pressure tube. These pre-simulations for Wolsong-1 Phase-B differ from those in the past that were performed for the Wolsong-1,2,3,4 tests in that these tests use the WIMS/DRAGON/RFSP-IST code suite for verification of the tests and gadolinium instead of the traditional PPV/MULTICELL/RFSP code system and boron as poison in the moderator system. The use of gadolinium is deemed not to have domestically accumulated experience gained from the previous Phase-B tests. Thus, it is appropriate to conduct a study in order to gain a correct understanding and interpretation of potential differences in test results stemming from using gadolinium rather than boron. Although the calibration of the reactivity device will not be noticeably different using boron and gadolinium at a constant moderator temperature, the temperature dependency of the neutronic behavior due to the presence of gadolinium in the moderator system might be pronounced. The results of the pre-simulations using gadolinium revealed that the moderator temperature reactivity coefficients indeed showed significant differences in comparison with those with boron. In order to secure the validity of the analysis results, the newly acquired WIMS/DRAGON/RFSP-IST code suite was verified against the W-2,3,4 Phase-B test results. The results of the new code suite verifications revealed some overall improvements in accuracy; justification of the use of the code can be claimed for the validation of the W-1 Phase-B test results.

Development of a Fast Neutron Detector (속중성자 탐지용 반도체 소자 개발)

  • 이남호;김승호;김양모
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.545-552
    • /
    • 2003
  • When a Si PIN diode is exposed to fast neutrons, it results in displacement damage to the Si lattice structure of the diode. Defects induced from structural dislocation become effective recombination centers for carriers which pass through the base of a PIN diode. Hence, increasing the resistivity of the diode decreases the current for the applied forward voltage. This paper involves the development of a neutron sensor based on the phenomena of the displacement effect damaged by neutron exposure. The neutron effect on the semiconductor was analyzed. Several PIN diode arrays with various thickness and cross-section area of the intrinsic layer(I layer) were fabricated. Under irradiation tests with a neutron beam, the manufactured diodes have a good linearity to neutron dose and show that the increase of thickness of I layer and the decrease of cross-section of PIN diodes improve the sensitivity. Newly developed PIN diodes with thicker I layer and various cross section, were retested and then showed the best neutron sensitivity at the condition that the I layer thickness was similar to a side length. On the basis of two test results, final discrete PIN diodes with a rectangular shape were manufactured and the characteristics as neutron detectors were analyzed through the neutron beam test using on-line electronic dosimetry system. Developed PIN diode shows a good linearity as dosimetry in the range of 0 to 1,000cGy(Tissue) and its neutron sensitivity is 13mV/cGy at constant current of 5mA, that is three times higher than that of commercially available neutron detectors. And the device shows little dependency on the orientation of the neutron beam and a considerable stability in annealing test for a long period.

Loading Rate Effect on the Lateral Response of H-Shape Steel Column (재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향)

  • Park, Minseok;Kim, Chul-Young;Han, Jongwook;Chae, Yunbyeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.637-644
    • /
    • 2021
  • Dynamic response of structures can be evaluated experimentally by conducting cyclic loading tests. It has been known that steel materials are rate-dependent and the lateral response of a structure is significantly affected by the presence of axial force. However, the rate-dependency of steel column structures subjected to both axial and lateral loads has not been sufficiently studied yet due to the difficulty of controlling the axial force in a real-time manner during test. This study introduces an advanced way to apply the axial load in real-time to a column specimen using the adaptive time series (ATS) compensator and the flexible loading beam (FLB), where the H-shape steel columns made of SS275 are used for monotonic and cyclic loading tests with various loading rates with axial loads. The lateral strength and post-yield response of the steel columns are compared for each of monotonic and cyclic loading tests. The estimating equation of yield stress of various strain rate has proposed and finite element analysis were performed for comparison.

An Experimental Study for the Shear Property Dependency of High Damping Rubber Bearings (고감쇠 고무받침의 전단특성 의존성에 대한 실험적 연구)

  • Oh, Ju;Jung, Hie-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.121-129
    • /
    • 2010
  • In this paper, the characteristics of high damping rubber bearing were studied through various prototype test. The characteristics of HDRB were dependent on displacements, repeated cycles, frequencies, vertical pressure, temperature, the capability of shear deformation and the vertical stiffness. The prototype test showed that the displacement was the most governing factor influencing on characteristics of HDRB. The effective stiffness and equivalent damping of HDRB were decreased with displacement, and increased with frequency. The effective stiffness was decreased with high vertical pressure, while the equivalent damping was increased. In which, the equivalent damping was more dependent on the vertical pressure than the effective stiffness. According to the results of this study, more careful examination is required to design the effective stiffness and equivalent damping ratio considering the dependencies of design displacement and exciting velocity.

A Study on the Care Needs of Family-Caregivers to the Patients with Stroke (뇌졸중환자 가족의 간호요구)

  • Kim Mi-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.4 no.2
    • /
    • pp.175-192
    • /
    • 1997
  • The purpose of this study was to identify the care needs of family-caregivers to the patients with stroke. Subjects were 115 family-caregivers caring for the patients while they were in-patients or out-patients with stroke in two general hospitals and one oriental medicine hospital located in Seoul and Kwang-Ju. The instrument used for this study was made by the researcher on the basis of results of literature review and interviews with family-caregivers, composed of 35 items. Internal validity by calculation of cronbach's alpha with data of respondents was 0.91, which was regarded as high. The Data were analyzed by SAS program, with percentage, mean, t-test, and ANOVA. Factor structures of care needs of family-caregivers were elicited by factor analysis(PCA, Varimax rotation). Datum collection had been from July 1 to August 14, 1997. The results of this study were as follows : 1. The mean score of the sum of the care needs of family-caregivers was 3.96 and the highest-mean item was 'need for immediate care(M=4.77)', and the lowest-mean item was 'need for chaplian's visit (M=2.82)'. 2. Care needs of the family-caregivers were : Need to be informed of the disease, treatment and care ; need of education and assistance related to physical functional level ; need of social support and consultation ; need of management of nursing problem related to immobility ; need of appreciation ; need of the way to communicate with patients ; need of immediate care and help. The highest mean factor was the 'need for immediate care and help(M=4.74)', and the lowest mean factor was the 'need of appreciation(M=3.58)'. 3. The variables influencing the degree of care needs perceived by family-caregivers to the patients with stroke were as follows : There were significant differences between need to be informed of the disease, treatment and care and general characteristic factors, which were family caregiver's sex (p=.0178), caring period(p=.0223) and patient's suffering period(p=.0244). There were significant differences between need of education and assistance related to physical functional level and general characteristic factors, which were patient's paralysis(p=.0177), patient's ADL dependency(p=.0032). There were significant differences between need of social support and consultation and general characteristic factors, which were family caregiver's sex(p=.0055), occupation(p=.0159), religion(p=.0093) and patient's sex(p=.0134). There was significant difference in the degree of need of management of nursing problem related to immobility, according to the patient's ADL dependency(p=.0493). There were significant differences between need of appreciation and general characteristic factors, which were family caregiver's age(p=.0107), sex(p=.0133), and patient's age(p=.0338). There were significant differences between need of the way to communicate with patient and general characteristic factors, which were patient's paralysis(p=.0002) and aphasia(p=.0001). There were significant differences between need of immediate care and help and general characteristic factors, which were family caregiver's caring period(p=.0162) and patient's suffering period(p=.0116). 4. The mean score of patient's ADL dependency was 3. 38 and the highest-mean item was 'ascending and descending stairs(M=4.12)', and the lowest-mean item was 'drinking(M=2.60)'. There was no significant difference in the degrees of care needs related to the patient's ADL dependency. 5. The highest information source of family-caregivers was from the doctors about the disease, treatment and care(26.1%). The second highest one was from mass media(20.8%), and the third one was from the nurses. The above findings may be used as the basic data to seek more efficient way of elevating nursing practice and quality for family-caregivers to the patients with stroke.

  • PDF

A Study of the Temperature Dependency for Photocatalytic VOC Degradation Chamber Test Under UVLED Irradiations (UVLED 광원을 이용한 광촉매 VOC 제거 특성 평가시 온도에 따른 농도 변화에 관한 연구)

  • Moon, Jiyeon;Lee, Kyusang;Kim, Seonmin
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.755-761
    • /
    • 2015
  • Photocatalytic VOCs removal test in gas phase is generally performed by placing the light source on the outside due to maintaining a constant temperature inside the test chamber. The distance between light source and photocatalysts is importantin the VOC degradation test since the intensity of light is rapidly decreased as the distance farther. Especially, for the choice of light source as UVLED, this issue is more critical because UVLED light source emits lots of heat and it is hard to measure the exact concentration of VOCs due to changed temperature in the test chamber. In this study, we modified VOC removal test chamber base on the protocol of air cleaner test and evaluated the efficiency of photocatalystunder UVLED irradiation. Photocatalystsof two different samples (commercial $TiO_2$ and the synthesized vanadium doped $TiO_2$) weretested for the p-xylene degradation in the closed chamber system and compared with each other in order to exclude any experimental uncertainties. During the VOC removal test, VOC concentrations were monitored and corrected at regular time intervals because the temperature in the chamber increases ${\sim}20^{\circ}C$ due tothe heat of UVLED. The results showed that theconversion ratio of p-xylene has 40~43% difference before and after the temperature correction. Based on those results, we conclude that the VOC concentration correction must be required for the VOC removal test in a closed chamber system under UVLED light source and obtained the corrected efficiencies of various photocatlysts.

Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - III. Bacterial Reverse Mutation Testing of Hydrolyzed Whey Protein Powder Containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method - (Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - III. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말의 미생물복귀돌연변이시험 연구 -)

  • Kim, Hee-Kyong;Noh, Hye-Ji;Cho, Hyang-Hyun;Koh, Hong Bum
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2016
  • The ultimate research goal of the current study was a development of hydrolyzed whey protein powder (7%-GNANA) manufactured with normal content of sialic acid, a marker compound, that is naturally occurring at 7% concentration in GMP obtained from the milk protein. GMP is a safe food, used worldwide in infant and baby foods, etc. The test substance was prepared using (7% sialic acid containing) GMP as a raw material, and then using alcalase, an enzyme approved as a food additive, after separation of sialic acid with 100% efficiency and 7%-GNANA (containing 7% sialic acid and protein; product name: HELICOBACTROL-7) provided by MEDINUTROL Inc. (Korea). Bacterial reverse mutation (Ames) test was conducted in accordance with GLP Guideline using the test substance specified above. To identify its mutagenic potential against microorganisms, histidine auxotrophic strains of Salmonella Typhimurium, TA98, TA100, TA1535, and TA1537, and tryptophan auxotrophic strain of Escherichia coli, WP2uvrA, were used. The bacterial reverse mutation (Ames) test was performed by dividing the test substances into five different concentration groups (0, 61.7, 185, 556, 1,670, $5,000{\mu}g/plate$). Results of this experiment did not reveal repetitive increase of colony generating values or positive criteria for reverse mutagenicity for any concentration of test substances in any of the five strains, regardless of the presence of a metabolic activation system, and no dose-dependency was identified. In conclusion, the safety of 7%-GNANA test substance was verified by bacterial reverse mutation test conducted before registration of 7%-GNANA as a food additive.

Bacterial Reverse Mutation Test Evaluation of Hydrolyzed GMP Powder Containing Highly Concentrated Sialic Acid (23%) produced by Enzyme Separation and Solvent Enrichment Method (효소분리 및 용매정제법으로 제조한 고농도 Sialic Acid(23%)가 함유된 GMP 가수분해분말의 미생물복귀돌연변이시험 연구)

  • Kim, Hee-Kyong;Cho, Hyang-Hyun;Noh, Hye-Ji
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • The goal of this study was to develop hydrolyzed whey protein powder (23%-GNANA) manufactured with high content of sialic acid, a marker compound that is usually present at 7% concentration in GMP obtained from the milk protein. It is a safe food, used worldwide in infant and baby foods, etc. The test substance was prepared using (7% sialic acid containing) GMP as a raw material. Alcalase, an enzyme approved as a food additive, was used after separating sialic acid, with 100% efficiency, and 23%-GNANA (composed of 23% sialic acid and protein; product name: HELICOBACTROL-23), provided by MEDINUTROL Inc. (Korea), manufactured to have high (23%) content through ethanol soaking and enrichment. Bacterial reverse mutation (Ames) test was conducted in accordance with the GLP Guideline using the test substance specified above. To detect its mutagenicity potential in microorganisms, histidine auxotrophic strains of Salmonella typhimurium, TA98, TA100, TA1535, and TA1537, and tryptophan auxotrophic Escherichia coli strain, WP2uvrA, were used. The bacterial reverse mutation (Ames) test was performed using five concentrations of the test substances (0, 61.7, 185, 556, 1,670, $5,000{\mu}g/plate$). The evaluation did not reveal repetitive increase of colony generating values and positive criteria for reverse mutagenicity for any tested concentration in the five strains regardless of the presence of metabolic activation system, and no dose-dependency. In conclusion, the safety of 23%-GNANA test substance was verified by the bacterial reverse mutation test conducted before registration of 23%-GNANA as a food additive.

Evaluation the Output Dose of Linear Accelerator Photon Beams by Blind Test with Dose Characteristics of LiF:Mg,Cu,P TLD (LiF:Mg,Cu,P 열형광선량계의 선량특성을 이용한 눈가림법에 의한 출력선량 평가)

  • Choi, Tae-Jin;Lee, Ho-Joon;Yie, Ji-Won;Oh, Young-Gi;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.308-316
    • /
    • 2009
  • To achieve the accurate evaluation of given absorbed dose from output dose of linear accelerator photon beam through investigate the characteristics of LiF:Mg,Cu,P TLD powder. This experimental TL phosphor is performed with a commercial LiF:Mg,Cu,P powder (Supplied by PTW) and TL reader (LTM, France). The TLD was exposed to 6 MV X rays of linear accelerator photon beam with range 15 to 800 cGy in blind dose at two hospitals. The dose evaluation of TLD was through the experimental algorithms which were dose dependency, dose rate dependency, fading and powder weight dependency. The glow curve has shown the three peaks which are 110, 183 and 232 degrees of heating temperature and the main dosimetric peak showed highest TL response at 232 high temperature. In this experiments, the LiF:Mg,Cu,P phosphor has shown the 2.5 eV of electron trap energy with a second order. This experiments guided the dose evaluation accuracy is within 1% +2.58% of discrepancy. The TLD powder of LiF:Mg,Cu,P was analyzed to dosimetric characterists of electron captured energy and order by glow shape, and dose-TL response curve guided the accuracy within 1.0+2.58% of output dose discrepancy.

  • PDF

Continuity Simulation and Trend Analysis of Water Qualities in Incoming Flows to Lake Paldang by Log Linear Models (로그선형모델을 이용한 팔당호 유입지류 수질의 연속성 시뮬레이션과 경향 분석)

  • Na, Eun-Hye;Park, Seok-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.336-343
    • /
    • 2003
  • Two types of statistical models, simple and multivariate log linear models, were studied for continuity simulation and trend analysis of water qualities in incoming flows to Lake Paldang. Water quality is a function of one independent variable (flow) in the simple log linear model, and of three different variables (flow, time, and seasonal cycle) in multivariate model. The independent variables act as surrogate variables of water quality in both models. The model coefficients were determined by the monthly data. The water qualities included 5-day Biochemical Oxygen Demand ($BOD_5$), Total Nitrogen (TN), and Total Phosphorus (TP) measured from 1995 to 2000 in the South and the North branches of Han River and the Kyoungan Stream. The results indicated that the multivariate model provided better agreements with field measurements than the simple one in a31 attempted cases. Flow dependency, seasonality, and temporal trends of water quality were tested on the determined coefficients of the multivariate model. The test of flow dependency indicated that BOD concentrations decreased as the water flow increased. In TN and TP concentrations, however, there were no discernible flow effects. From the temporal trend analyses, the following results were obtained: 1) no trends on BOD at all three upstreams, 2) increase on TN at the South Branch and the Kyoungan Stream, 3)decrease on TN at the North Branch,4) no trends on TP at the North and the South Branches and 5) increase on TP at the Kyoungan Stream by 3 to 8% per years. The seasonality test showed that there were significant seasonal variations in all three water qualities at three incoming flows.