• 제목/요약/키워드: dental restorations

검색결과 530건 처리시간 0.036초

사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING)

  • 양성욱;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

디지털 아트를 위한 기다림 - 디지털 대 아날로그 (Waiting for Digital Art - digital vs analogue)

  • 신준혁
    • 대한심미치과학회지
    • /
    • 제22권1호
    • /
    • pp.22-29
    • /
    • 2013
  • 일반적으로 심미 보철을 진행하기 위해서는 초진 시부터 카메라를 사용해서 최종 보철물을 고려하며 여러 가지 분석을 한다. 이 부분에서 많은 치의들이 디지털카메라를 사용하고 있는 현실을 볼 때, 우리는 이미 digital impression을 시작하고 있는 것이 아닐까 생각한다. 최근 세계적인 photographer들도 필름카메라에서 디지털카메라로 넘어오는 추세가 많아지고 있는 것처럼 심미 치과학에서도 CAD/CAM은 향후 우리가 추구하고자 하는 심미 영역에서의 또 한가지 방향성을 제시해 줄 수 있지 않을까 하는 생각이 든다. 흔히 디지털이라고 하면 편의성, 경제성 등을 먼저 떠올리는 경향이 있다. 그러나 치과 임상적 관점에서 기존의 analog방식을 존중하며 CAD/CAM system이 가지는 그 특수성과 우수성을 고민하고 이를 개선, 발전시키는 것 또한 중요하다고 생각된다. 다만 아쉬운 것은 CAD/CAM 장치와 소재가 급격히 발전하는 이유로 인하여 reference, follow-up이 어려운 경우가 많다. 이에 digital은 변화하는 속도가 굉장히 빠르기 때문에, 여러 가지 소재와 장치들을 접해보고 경험해보면서 그에 맞게끔 발맞춰 적용해 볼 수밖에는 없지만 임상에 적용하여 보다 좋은 결과 얻기 위해서는 전통적인 방식이 기본바탕이 된 상태에서 이루어져야 한다는 점을 강조하고 싶다. 본 연구에서는 심미적 관점에서 전통적인 방식과 CAD/CAM과의 조화 통해서 어떤 접근을 할 수 있는지에 대해서 살펴보고자 한다. 그리고 CAD/CAM 보철이 'Digital art' 영역에 한 축의 역할을 할 수 있기를 기다리고 열망한다.

수종의 광중합기에 의한 복합레진 중합시 미세누출에 관한 연구 (MICROLEAKAGE IN RESIN COMPOSITE POLYMERIZED WITH VARIOUS LIGHT CURING UNITS)

  • 박성진;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제32권4호
    • /
    • pp.604-610
    • /
    • 2005
  • 현재 광중합 복합레진은 치아의 수복을 위하여 많이 사용되며 복합레진이 많이 사용되는 만큼 광중합을 위한 광중합기도 다양하게 사용된다. 하지만 광중합기에 따른 복합레진의 미세누출은 아직 연구대상이다. 본 연구의 목적은 광중합기에 따라 발생하는 미세누출에 대한 평가를 하는 것으로 최근에 개발된 광중합기의 중합능력을 전통적 인 할로겐 광중합기와 비교하는 것이다. 전통적으로 사용되어지던 저출력 할로겐 광중합기(Optilux 360), 일반 플라즈마 아크 광중합기(Flipo). 저발열 플라즈마 아크 광중합기 (Aurys), 고출력 LED 광중합기 (Freelight 2)를 사용하였다. 건전한 유구치에 와동을 형성한 후 복합레진(Z100)을 동일한 레진 접착제 (Scotchbond Multi-Purpose)를 사용하여 충전한 후 각 광중합기를 이용하여 복합레진을 중합시켰다. 광중합기의 광조사 시간은 제조사에서 복합레진의 광중합을 위해 권장하는 시간으로 Optilux 360은 40초, Flipo는 5초, Aurys는 9초, Freelight 2는 20초간 조사하였다. Optilux 360만 광강도의 변화가 없는 광조사 방식이며 그 외 광중합기들은 광강도가 광조사 중에 증가되는 soft-start 광조사 방식이다. 각 시편을 증류수에 24시간 보관 후 열 순환을 1000회 시행한 후 2% methylene blue용액으로 색소침투를 시켰으며 각 시편을 절단하여 색소침투 정도를 점수화시켜 다음과 같은 결론을 얻었다. 미세누출을 각 점수화하였을 때 Aurys가 평균 0.95로 가장 낮은 값을 보였고 Freelight 2(1.05), Flipo(1.25), Optilux 360(1.30)의 순이었다. 하지만 각 광중합기군 간의 값에서는 통계학적인 유의성은 관찰되지 않았다(P>0.05).

  • PDF

디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동 (Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.125-132
    • /
    • 2020
  • 치과용 복합레진 Filtek P90 (3M ESPE, USA)과 Clearfil AP-X (Kuraray, Japan)를 대상으로 디지털 이미지 상관법을 이용하여 광중합 시 발생하는 수축거동을 관찰하고 등가탄성계수를 적용한 유한요소해석을 통해 시편표면의 응력분포를 산출하여 수축률분포와 비교하였다. 광조사 중과 광조사 후의 촬영 조건을 달리하여 CCD 카메라를 이용한 시편의 변형사진을 획득하고 디지털 이미지 상관분석을 하였다. DIC 분석 결과 상기의 복합레진 모두에서, 비균일한 수축변형률 분포가 관찰되었으며 링시편 내부의 레진 중심부가 자유로운 유동성으로 레진/링의 계면부보다 큰 수축 변형률이 발생하였다. 레진의 중심으로부터 거리가 멀어질수록 반경방향 평균수축률은 감소하였으며, 광조사동안에 발생한 반경방향 평균수축률은 경화시험종료(10 min) 후 발생한 반경방향 평균수축률 값을 기준으로 P90은 33%, AP-X는 57% 수준이었다. P90과 AP-X가 광조사 중의 수축거동이 크게 달랐음을 확인하였다. 레진/링의 계면부에 가까운 레진에서는 광조사 후에 인장변형률이 급격히 커져서 계면부가 인장응력을 받아 취약하게 됨을 확인하였다.

치아용 세라믹스에서의 접촉피로 및 강도저하 (Contact fatigue and strength degradation in dental ceramics)

  • 정연길;이수영;최성철
    • 한국결정성장학회지
    • /
    • 제9권5호
    • /
    • pp.527-533
    • /
    • 1999
  • 치아용 대체재료로 사용되고 있는 세 가지의 세라믹스, 장석질 자기, 운모를 함유한 유리-세라믹 및 유리침윤 알루미나에 대한 접촉피로을 실제 치아의 접촉상황과 유사한 구형입자를 이용한 헤르지안 압입시험법으로 물에서 수행하였으며, 각 재료에서의 접촉손상이 강도에 미치는 영향을 고찰하였다. 초기의 손상형태는 각 재료가 갖는 미세구조에 의존하여 나타났으며, 장석질 자기는 취성거동을 나타내는 cone 형태의 균열이, 운모를 함유한 유리-세라믹은 준-소성 변형 거동을 나타내는 변형이, 그리고 유리침윤 알루미나는 두 재료의 중간거동을 나타내었다. 그러나 반복하중의 수(n=1~n=$10^6$)가 증가됨에 따라 모든 재료에서 급격한 강도저하를 나타내었으며, 파괴는 접촉피로에 의해 형성된 손상에서 일어났다. 일정하중(200N, 500N 및 1000N)에서 반복하중의 수가 증가됨에 따라 두 번의 강도저하가 일어났으며, 첫 번째의 강도저하는 cone 형태의 균열이 주 요인으로 작용되었으며, 두 번째 강도저하는 반복하중에 따른 radial 형태의 균열에 의해 일어났다. 이러한 radial 형태의 균열발생은 각 재료에서 급격한 강도저하를 가져왔으며, 계속적인 반복하중으로 재료의 파괴를 유발시켰다. 반복하중의 수를 고정시킨 수 압입하중의 변화에 따른 강도저하에 대한 고찰을 통해 장석질 자기가 접촉피로에 대한 손상내구성을 갖음을 알 수 있었다.

  • PDF

구강양치용액이 복합레진의 색조 안정성과 표면미세경도 및 표면조도에 미치는 영향 (The Effect of Oral Rinsing Solution on the Color Stability, Surface Microhardness and Surface Roughness Change of Composite Resin)

  • 이혜진;김민영;양달님
    • 융합정보논문지
    • /
    • 제9권7호
    • /
    • pp.159-167
    • /
    • 2019
  • 본 연구는 구강양치용액이 복합레진의 색조 안정성과 표면미세경도 및 표면조도에 미치는 영향에 대하여 알아보고자 하였으며, 실험실 연구로 Filtek P60과 Filtek Z250의 두 종류의 복합레진으로 시편을 제작하였다. 각 시편은 10개씩 8개 그룹으로 나누었다. 실험전 모든 시편을 colorimater를 이용하여 색조($L^*$, $a^*$, $b^*$)를 측정하였다. 대조군으로 증류수, 실험군으로 무색소, 녹색 및 보라색을 띄는 시판 구강양치용액을 사용하여 14일간 색변화, 표면미세경도, 표면조도 등을 측정하여 수집된 자료들 분석하였다. 녹색 및 보라색을 띄는 구강양치용액에서 눈에 띄는 색변화를 보였고, 모든 구강양치 용액군에서 표면미세경도는 감소하고 표면조도는 거칠어진 양상이 관찰되었다. 따라서 구강양치용액을 2주 이상 장기간 사용하게 되면 복합레진 표면에 변화를 야기할 수 있으므로, 안전한 사용을 위하여 짧은 기간 사용을 권장해야 할 것으로 사료된다.

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

유아의 구강관리에 관한 보호자의 인지도 조사 (A STUDY OF PARENTAL KNOWLEDGE AND ATTITUDE ABOUT INFANT ORAL HEALTH CARE)

  • 김명진;선예경;심연수
    • 대한소아치과학회지
    • /
    • 제27권2호
    • /
    • pp.292-299
    • /
    • 2000
  • 전반적인 유아의 구강관리에 관한 보호자의 인지도를 알아 보고, 이를 통한 구강관리에 대한 동기유발을 목적으로 1998년 7월부터 1998년 8월까지 삼성서울병원 소아과에 내원한 아동과 강남구 일원동 일대 유치원 및 어린이집 8곳의 만 3세 이하아동 350명의 보호자를 대상으로 시행한 설문 조사를 통해 다음과 같은 결과를 얻었다. 1. 남성보다는 여성이, 그리고 교육정도가 높을수록 치과 지식정도가 높았으며, 연령이나 경제 수준과는 무관하게 나타났다. 2. 치아의 생성시기에 대해 응답자의 59%가 태아기라고 답하였다. 3. 구강관리 시작시기는 응답자의 76%가 맹출 전이라고 하였으며, 63%가 실제로 만 1세 미만에 구강관리를 시작한다고 하였다. 4. 구강관리 방법에 대해 응답자의 70%가 거즈를 사용한다고 하였다. 5. 응답자의 57%가 만 1세 이후에도 계속 수유한다고 하였다. 6. 우유병 우식증에 대한 인지도는 45%로 나타났다. 7. 유치수복의 필요성에 대하여서는 90%가 필요하다고 하였으며, 31%에서 최초의 치과내원시기를 만 2세 경이라고 하였다. 8. 47%의 보호자가 치아우식이 감염성 질환임을 인식하지 못하였다. 9. 응답자의 33%만이 임신 중 치과 검진을 받았다고 하였고, 소아과나 산부인과에서 구강관리에 관한 지도를 받은 것은 11% 뿐이었다. 10. 주로 육아서적에서 유아의 구강관리에 관한 정보를 얻는 것으로 나타났다. 11. 보호자들의 전반적인 치과지식과 실천정도는 유아들에게 적절한 구강관리를 제공하기에 충분치 않은 것으로 나타났다.

  • PDF

단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향 (The effects of short-term application of calcium hydroxide on dentin fracture strength)

  • 신은정;박영준;이빈나;장지현;장훈상;황인남;오원만;황윤찬
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.425-430
    • /
    • 2011
  • 연구목적: 인간의 영구치에서 수산화 칼슘을 근관계에 단기간(1주 또는 4주)으로 적용하였을 때 파절강도에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: 단일 치근을 가지며, 유사한 크기 및 상아질 두께를 보이고, 우식이나 수복물이 없는 32개의 하악 소구치를 이용하였다. 16개의 치아에는 수산화 칼슘을 충전한 후 임시가봉 하였고, 나머지 16개의 치아는 대조군으로서 충전하지 않은 상태에서 임시가봉 하였다. 모든 시편의 치근단을 레진으로 밀봉한 후, $37^{\circ}C$ 식염수에 보관하였다. 1주와 4주 후에 시편을 파절시키기 위해 필요한 힘의 최대값을 측정하여 통계학적으로 분석하였다. 결과: 1주, 4주 후 두 그룹의 평균 파절강도는 유사하였다. 수산화 칼슘을 근관 내에 4주간 적용한 경우에는 파절강도가 대조군에 비해 8.2% 감소하였다. 그러나 통계학적으로 실험군간, 시간대별 유의한 차이는 보이지 않았다. 결론: 수산화 칼슘을 단기간 적용할 경우 치아의 파절강도에 큰 영향을 미치지 않는다. 따라서, 근관치료 과정 동안 수산화 칼슘을 단기간으로 적용할 수 있다.

부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 - (A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF