• Title/Summary/Keyword: dental patients

Search Result 4,526, Processing Time 0.034 seconds

Transoral removal of proximal submandibular stone: report of 5 cases and review of the literature (구강 내 접근법에 의한 심부 악하선 타석제거술)

  • Lim, Kyoung-Min;Lee, Seung-June;Kil1, Tae-Jun;Choi, Eun-Ju;Kim, Hyung-Jun;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.6
    • /
    • pp.548-552
    • /
    • 2010
  • The submandibular gland is the second largest major salivary gland, which secretes 40% of the total daily saliva. Owing to its anatomic characteristics as well as the high viscosity and basicity of the saliva, sialolithiasis is found most commonly in the submandibular gland. Sialolithiasis that cannot be treated by conservative treatment is conventionally removed by an excision of the submandibular gland. Generally, an excision of the submandibular gland is performed via an extra-oral approach but the disadvantages of this treatment include a risk of injuring the facial nerve and scar formation. Case reports have revealed an even less invasive intraoral surgical technique for the removal of sialolith that does not affect the submandibular gland function. The functional recovery of the gland, complications and recurrence rates after surgery with this conservative intraoral procedure were all successful. We report 5 patients from the department of Oral and Maxillofacial Surgery at Dental Hospital, Yonsei University, who had undergone a resection of the sialolith though the intraoral approach with successful results.

Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery

  • Bari, Roberto Di;Coronelli, Roberto;Cicconetti, Andrea
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.135-143
    • /
    • 2013
  • Purpose: This study was performed to obtain a quantitative evaluation of the cortical and cancellous bone graft harvestable from the mental and canine regions, and to evaluate the cortical vestibular thickness. Materials and Methods: This study collected cone-beam computed tomographic (CBCT) images of 100 Italian patients. The limits of the mental region were established: 5 mm in front of the medial margin of each mental foramen, 5 mm under the apex of each tooth present, and above the inferior mandibular cortex. Cortical and cancellous bone volumes were evaluated using SimPlant software (SimPlant 3-D Pro, Materialize, Leuven, Belgium) tools. In addition, the cortical vestibular thickness (minimal and maximal values) was evaluated in 3 cross-sections corresponding to the right canine tooth (3R), the median section (M), and the left canine tooth (3L). Results: The cortical volume was $0.71{\pm}0.23mL$ (0.27-1.96 mL) and the cancellous volume was $2.16{\pm}0.76mL$ (0.86-6.28 mL). The minimal cortical vestibular thickness was $1.54{\pm}0.41mm$ (0.61-3.25 mm), and the maximal cortical vestibular thickness was $3.14{\pm}0.75mm$ (1.01-5.83 mm). Conclusion: The use of the imaging software allowed a patient-specific assessment of mental and canine region bone availability. The proposed evaluation method might help the surgeon in the selection of the donor site by the comparison between bone availability in the donor site and the reconstructive exigency of the recipient site.

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

Comparison of immediate complete denture, tooth and implant-supported overdenture on vertical dimension and muscle activity

  • Shah, Farhan Khalid;Gebreel, Ashraf;Elshokouki, Ali Hamed;Habib, Ahmed Ali;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.61-71
    • /
    • 2012
  • PURPOSE. To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS. Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS. Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION. Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.

Use of Digital Smile Design in esthetic restoration in anterior teeth: A case report (전치부의 심미 수복을 위하여 Digital Smile Design을 적용한 증례)

  • Shin, Sejun;Noh, Kwantae;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.164-170
    • /
    • 2017
  • When restoring their anterior dentition, patients become more demanding on esthetics compared to posterior region during treatment planning phase. Digital Smile Design (DSD) procedure is performed in presentation software and digital photographs. This can widen diagnostic visualization and aid in transferring information between clinician, patient, and technician. This case presented is that of patient with dissatisfaction of his anterior old restoration. Retreatment procedures were carried out in two different manners: (1) using DSD protocol for diagnosis, smile simulation, communication and fabricating interim and definitive prosthesis by totally digitized workflow. (2) Using diagnostic wax-up for smile design and fabricating restorations by conventional workflow. Comparing two methods, DSD was easier to communicate between the dental team than the diagnostic wax-up method. But the final result obtained failed to meet total esthetic factors. Therefore, to obtain predictable esthetic results, more advanced design tool would be needed, including consideration of various esthetic factors besides successful communications.

Autotransplantation of Premolars and Esthetic Rehabilitation in a Traumatized Teenage Patient with Challenging Oral Problems: A Case Report (어려운 구강 문제를 가진 외상당한 청소년 환자의 소구치 자가이식 및 심미적 회복: 증례 보고)

  • Kho, Junhee;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.213-218
    • /
    • 2020
  • The loosely structured periodontal ligament and low mineralized bone surrounding erupting teeth provide minimal resistance to an extrusive force. The maxillary central incisors are the most frequently avulsed due to trauma. The prognosis of replanted teeth is affected by extra-alveolar period and conditions. Implant-supported restorations are contraindicated in adolescent patients with poor prognosis traumatized teeth. Autotransplantation of premolar to the anterior region provides a viable treatment alternative. This case report describes the autotransplantation of premolars and esthetic rehabilitation in a teenage patient with traumatized incisors, poor oral hygiene, and severe crowding. Comprehensive and long-term treatments were performed to improve complex and challenging oral problems.

A Study on the Position of the Maxillary Anterior Teeth in Korean Adults with Natural Dentition (한국 성인 유치악자의 상악전치 위치에 관한 연구)

  • Jeong, Chang-Mo;Park, Jeong-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • It is essential to establish the suitable position for artificial maxillary anterior teeth, because of not only esthetics, phonetics, mastication, but also optimal position of artificial posterior teeth for the construction of functional and esthetic prostheses. Anatomic landmarks have been used in the arrangement of artificial teeth. Such as incisive papilla and palatal rugae are useful landmarks for positioning occlusal rim and upper anterior artificial teeth because they are relatively stable and to be identified on master cast. Therefore, if average distance between maxillary anterior teeth and landmarks in dentate subjects are measured and applied, appropriate position of occlusal rim can be initially established. In this study, to present a guide to the position of the occlusal rim for upper anterior teeth of edentulous patients, horizontal distance between anatomic landmarks were measured. Maxillary casts were made in 72 Korean dentate subjects. Horizontal distance between central incisor and incisive papilla, between incisive papilla and intercanine line, and between primary palatine rugae and gingival margin of canine were measured on each cast. The results of this study were as follows ; 1. The mean distance from the incisal edge of central incisor to the posterior border of incisive papilla was 12.1 mm (Male 12.2 mm, Female 11.9 mm). 2. The mean distance between posterior border of incisive papilla and intercanine line was 3.5 mm (Male 3.4 mm, Female 3.6 mm / Left 3.6 mm, Right 3.4 mm). 3. The mean distance from the palatal gingival margin of canine to the lateral border of primary palatine rugae was 2.4 mm (Male 2.4 mm, Female 2.4 mm / Left 2.4 mm, Right 2.3 mm). 4. On all measured items, there were no significant differencies in measured values between male and female, and between left and right sides. (P>0.05).

The prosthetic approach and principle for an collapsed VDO : A clinical case of Class II div.2 patient (저위교합환자의 보철적 접근법과 이론 : Class II div.2 교합환자 증례)

  • Kwon, Kung-Rock
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.95-107
    • /
    • 2004
  • The prosthodontic treatment of Class II division 2 malocclusions is challenging. Ideally, these malocclusions should be identified at an early age and corrected with orthodontic treatment; otherwise, the individual develops a habitual position characterized by deep overbite and significant retruded position of mandibular condyle at the TMjoint fossa. This article describes a clinical protocol for the occlusal rehabilitation of patients with Class II div.2 malocclusions. Within this protocol, an occlusal splint was used to locate the most suitable maxillary-mandibular relationship for function and range of motion. The splint increased the vertical dimension and reduced pain on TMjoints. After transfer this relationship to an articulator for fabrication of provisional restorations, the CR position and centric prematurity contact between maxilla and mandible was used to determine the tentative vertical dimension of occlusion(VDO). The amount of elevation of VDO was decided on the articulated model. The provisional restorations were accurately transfered to a patient's mouth in clinical procedures using tattoo points. The final restoration was delivered after some trial periods with provisional restorations. The theory behind this protocol and its associated clinical procedures is presented along with a discussion.

Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis (임플란트 보철의 교합 접촉 변화에 대한 임상적 평가)

  • Yun, Chul-Hee;Kim, Dae-Gon;Yi, Yang-Jin;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.