• Title/Summary/Keyword: dental handpiece

Search Result 57, Processing Time 0.022 seconds

Temporary Threshold Shift of Vibration Sensation by Dental Handpiece (치과용 핸드피스에 의한 일시적 진동감각역치 변화)

  • Kim, Seong-Ah;Lee, Jong-Young;Kim, Doo-Hie;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.765-771
    • /
    • 1995
  • This study was performed to investigate the possibility of temporary threshold shift (TTS) of vibration sense could induced by exposure to high-frequency vibration or by work position taking by dentists in drilling or polishing. The vibratory perception thresholds (VPT) of 28 healthy men were measured on the index fingertip pulp of dominant hand at 250 Hz. The vibrating tool used in test was a low-speed handpiece of 34,000 rpm. For the TTS test, the dominant hand was exposed to high-frequency vibration and to work position for five minutes, respectively. The VPTs before and after vibratory exposure were $23.5{\pm}3.5dB,\;30.8{\pm}4.2dB$, respectively and VPT after work position was $23.7{\pm}4.6dB$. The difference between before and after vibartory exposure was statistically significant (p<0.001). The correlation of height, weight and BMI with baseline VPTs was not statistically significant. Also, there was no difference of VPTs by smoking. These results suggest that high-frequency vibration from dental handpieces might cause the impairment of vibration sensation.

  • PDF

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Quantitative and qualitative analysis of microorganisms in dental unit water (치과용수 미생물의 정량적 및 정성적 분석)

  • Lee, Seung-Hee;Park, Ji-Hye;Sakong, Joon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.4
    • /
    • pp.433-440
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the pathogenicity of microorganisms by quantitative and qualitative analysis of microorganisms before and after flushing of dental unit water. Methods: This study was conducted on the supply of high-speed handpieces, ultrasonic scalers, and air-water syringes, which sterilized from 10 dental unit chairs at a dental clinic in South Gyeongsang Province. The number of bacterial communities was calculated by collection before and after flushing (2, 4, and 6 minutes). Results: The mean number of bacteria in the handpiece water before flushing was $27,208CFU/m{\ell}$; 2 minutes after flushing, $2,180CFU/m{\ell}$; 4 minutes after flushing, $900CFU/m{\ell}$; and 6 minutes after flushing, $412CFU/m{\ell}$. Conclusions: To minimize the risk of cross-infection and intra-clinic infection in dental clinics, education and water quality monitoring may be needed.

Subcutaneous Emphysema and Pneumomediastinum during Extraction of Maxillary Third Molar: A Case Report

  • Jung, Da-Woon;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • Subcutaneous emphysema and pneumomediastinum is a relatively uncommon phenomenon. It may occur secondary to dental treatment using high-speed air turbine handpieces, especially after extraction of tooth. Subcutaneous emphysema is often limited only to the areas of head and neck, but also can involve deeper structures. Thorough examination and conservative treatment of these problems are essential in preventing life-threatening complications such as airway obstruction and mediastinitis. The subject of this report is a 57-year-old woman with subcutaneous emphysema and pneumomediastinum during the extraction of maxillary third molar using high-speed air turbine handpiece. If there isn't any appropriate measure, severe complications may occur. Therefore it is important to be well-informed of proper diagnosis and treatment. This article shall present a case report with literature review.

Percutaneous self-injury to the femoral region caused by bur breakage during surgical extraction of a patient's impacted third molar

  • Yu, Tae Hoon;Lee, Jun;Kim, Bong Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.281-283
    • /
    • 2015
  • Extraction of an impacted third molar is one of the most frequently performed techniques in oral and maxillofacial surgery. Surgeons can suffer numerous external injuries while extracting a tooth, with percutaneous injuries to the hand being the most commonly reported. In this article, we present a case involving a percutaneous injury of the surgeon's femoral region caused by breakage of the fissure bur connected to the handpiece during extraction of the third molar. We also propose precautions to prevent such injuries and steps to be undertaken when they occur.

THE ASSESSMENT OF NOISE IN THE PEDIATRIC DENTAL CLINICS (소아치과 진료실에서 발생하는 소음 평가)

  • Kwon, Bo-Min;Lee, Ji-Hyun;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.267-272
    • /
    • 2012
  • Dental professionals are exposed to various occupational risks, among which the problem of hearing damage has been newly revealed. There have been some researches reporting that noise occurring in a dental office exceeds the Occupational Safety and Health Act (OSHA) Standards. Especially, the pediatric dentists are repeatedly exposed to an additional noise source called the crying sound of children in addition to all kinds of noises from dental instruments. Accordingly, this study intended to investigate the noise environment likely to affect pediatric dentists and to examine the possibility of resultant hearing damages. The level of noise was measured respectively, when various dental instruments (ultrasonic scaler, high-speed handpiece, low-speed handpiece) are operated, when children are crying, and when both occasions take place simultaneously (from the distance of 30 cm) with a portable noise meter. And the daily duration of pediatric dentists exposed to the noise environment was surveyed. The results were compared with the standard value of noise threshold of NIOSH, OSHA, and that of hearing damage of CRA News letter respectively. Considering the intensity and exposure time, the noise environment of pediatric dentists exceeds the allowable noise threshold values. Even only one exposure to crying child was likely to lead to permanent hearing damage. Comparatively, pediatric dentists have a higher risk for occupational hearing damages, and some active measures are thought highly desirable to minimize it.

Awareness and practice of dental unit waterline management in dental hygienist (치과위생사의 치과 유니트 수관관리에 대한 인식과 실천도)

  • Lee, Seong-Sook;Kim, Dong-Ae;Song, Sun-Young;Kim, Mi-Yeon;Shim, Ha-Na
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.507-516
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the awareness and practice of dental unit waterline management in dental hygienist. Methods: A self-reported questionnaire was completed by 377 dental hygienists in Seoul and Gyeonggido from March 2 to April 30, 2015. The data were collected by direct visit and informed consent was received after explanation of the study. The questionnaire consisted of general characteristics of the subjects, awareness of dental waterline, practice of dental waterline, and implementation of dental waterline disinfection. Data were analyzed using SPSS 12.0 program. Results: There was a significant correlation between the dental unit waterline disinfection and the appropriateness of the water used for dental treatment(p<0.01, p<0.001). The handpiece was the most commonly used device before treatment and the majority of the subjects answered that they didn't take water out of ultrasonic scaler and air-water syringe on a daily basis. Conclusions: The majority of the dental hygienists did not know the right understanding and proper practice of dental unit waterline management. To reduce the dental device contamination, the continuing education of waterline management should be done for the dental hygienists.

A Study on Improvement of Dental Technicians practical examination system (치과기공사 국가시험 실기시험 제도 개선에 관한 연구)

  • Nam, Sang-Yong;Chung, In-Sung;Lee, Gyu-Sun;Kim, Ji-Hwan;Yu, Chin-Ho;Lee, Sun-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.27-37
    • /
    • 2014
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technicians practical examination system. Methods: The subjects in this study were 290 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 16.0. The collected data was analyzed by frequency and chi-square test. Results: Dental technician practical exam feasibility of survey were largely negative views. Articulators work required in practical exam as a tool used (28.7%), electric wax carver (19.5%), heating clear (17.8%), handpiece (16.2%) had a response. Dental Technician positions in accordance with practical exam in comparison to satisfaction, the professor is satisfied, but the clinical dental technicians were generally dissatisfied (p<0.05). Conclusion: Based on the results of this study, Current is necessary to analyze the practical test. It also should be compared with foreign institutions. Long-term and short-term improvement examination system that can be applied to the improvement of the dental technician to draw practical test it is necessary to improve the system.

AN EXPERIMENTAL STUDY ON RETENTIVE PROPERTIES OF VARIOUS PINS IN DENTIM (수종수복용 Pin의 유지력에 관한 실험적 연구)

  • Lee, Myung-Chong
    • The Journal of the Korean dental association
    • /
    • v.15 no.11
    • /
    • pp.763-766
    • /
    • 1977
  • The Purpose of this study was to observe force required to remove some kinds of pin from dentin. The teeth were embedded within a resin cylinder and the occlusal surface was sectioned at a right angle to the axis of the cylinder to expose dentin surface. Thread mate system pin (minim and regular), friction Iocked pin and cemented pin were tested Pin holes were drilled by handpiece and depths of pin holes were tested 1,2 and 3mm. After insertion of the pins into pinhole, tensile loading was performed on the Instron testing machine at the speed of 0.5 inch/min. Results were follewed: 1. In retention, the cemented pins are the least, the friction locked pins intermediate and the self threading pins the greatest in all pins. In self threading pins, regalar pin has greater retention than minim pin 2. The deeper the depth of the pin hole is, the more the retention of the pin increases.

  • PDF

Subcutaneous emphysema during removal of suture after intraoral surgery

  • Park, Jong-Chan;Shin, Hyeon-Seo;Son, Jeong-Wan;Lee, Jun;Kim, Bong-Chul;Lim, Hun-Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.8
    • /
    • pp.418-422
    • /
    • 2018
  • Subcutaneous emphysema is relatively rare postoperative complication in the oral and maxillofacial region. Most cases reported in maxillofacial area relate to the use of high-speed handpiece. However, in this case, subcutaneous emphysema was caused by compressed air blow performed during suture removal. Cone-Beam Computed Tomography was conducted to evaluate the extent of diffusion bubbles.. In this report, we describe etiology, diagnosis, prevention and management of subcutaneous emphysema in the maxillofacial area.

  • PDF