• Title/Summary/Keyword: dental ceramic

Search Result 560, Processing Time 0.029 seconds

Marginal and internal fit of interim crowns fabricated with 3D printing and milling method (3D 프린팅 및 밀링 방법으로 제작된 임시 보철물 적합도 비교 분석)

  • Son, Young-Tak;Son, KeunBaDa;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.254-261
    • /
    • 2020
  • Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manufacturing method (subtractive manufacturing technology and additive manufacturing technology). Materials and Methods: Forty study models were fabricated with plasters by making an impression of a master model of the maxillary right first molar for ceramic crown. On each study model, interim crowns (n = 40) were fabricated using three types of 3D printers (Meg-printer 2; Megagen, Zenith U; Dentis, and Zenith D; Dentis) and one type milling machine (imes-icore 450i; imes-icore GmbH). The internal of the interim crowns were filled with silicon and fitted to the study model. Internal scan data was obtained using an intraoral scanner. The fit of interim crowns were evaluated in the margin, absolute margin, axial, cusp, and occlusal area by using the superimposition of 3D scan data (Geomagic control X; 3D Systems). The Kruskal-wallis test, Mann-Whitney U test and Bonferroni correction method were used to compare the results among groups (α = 0.05). Results: There was no significant difference in the absolute marginal discrepancy of the temporary crown manufactured by three 3D printers and one milling machine (P = 0.812). There was a significant difference between the milling machine and the 3D printer in the axial and occlusal area (P < 0.001). The temporary crown with the milling machine showed smaller axial gap and higher occlusal gap than 3D printer. Conclusion: Since the marginal fit of the temporary crown produced by three types of 3D printers were all with in clinically acceptable range (< 120 ㎛), it can be sufficiently used for the fabrication of the temporary crown.

COLOR STABILITY OF CURRENT PROSTHETIC COMPOSITES UNDER ACCELERATED AGING AND IMMERSION IN A COFFEE SOLUTION

  • Kim, Hyo-Jin;Heo, Seong-Joo;Koak, Jai-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.225-235
    • /
    • 2002
  • The color stability of current prosthetic composites is unknown, even though the quality of composite materials has been improving. This study examined the intrinsic color stability of various current prosthetic resins (ceramic-polymers) after an accelerated aging process and the extrinsic color stability after immersion in a coffee solution. By comparing the amount of discoloration after aging with that without aging, the effect of the accelerated aging process on external discoloration could be evaluated. Three current prosthetic composites (Artglass, Targis, Sculpture), one light polymerized direct composite (Z100) and one dental porcelain control (Ceramco) were assessed. The color changes (${\Delta}$E) of all the specimens were determined using the CIE $L^{*}a^{*}b^{*}$ color order system with a reflected spectrophotometer. The results were as follows: 1. The prosthetic composite materials subjected to the accelerated aging test showed no significant difference in color changes (p >.05). 2. In the coffee solution immersion test after the aging process, the color changes of the Targis and Artglass groups were not different from that of the Z100 group, which showed the highest color change. 3. In the immersion only test, a significantly high color change was observed in the sculpture glazing group. 4. The aging process influenced on the color changes more in the Targis, Artglass and Z100 groups than in the Sculpture and Ceramco groups.

Effects of crown retrieval on implants and the surrounding bone: a finite element analysis

  • Ozkir, Serhat Emre;Unal, Server Mutluay;Yurekli, Emel;Guven, Sedat
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • PURPOSE. The aim of this study was to observe stress concentration in the implant, the surrounding bone, and other components under the pull-out force during the crown removal. MATERIALS AND METHODS. Two 3-dimensional models of implant-supported conventional metal ceramic crowns were digitally constructed. One model was designed as a vertically placed implant ($3.7mm{\times}10mm$) with a straight abutment, and the other model was designed as a 30-degree inclined implant ($3.7mm{\times}10mm$) with an angled abutment. A pull-out force of 40 N was applied to the crown. The stress values were calculated within the dental implant, the abutment, the abutment screw, and the surrounding bone. RESULTS. The highest stress concentration was observed at the coronal portion of the straight implant (9.29 MPa). The stress concentrations at the cortical bone were lower than at the implants, and maximum stress concentration in bone structure was 1.73 MPa. At the abutment screws, the stress concentration levels were similiar (3.09 MPa and 3.44 MPa), but the localizations were different. The stress at the angled abutment was higher than the stress at the straight abutment. CONCLUSION. The pull-out force, applied during a crown removal, did not show an evident effect in bone structure. The higher stress concentrations were mostly observed at the implant and the abutment collar. In addition, the abutment screw, which is the weakest part of an implant system, also showed stress concentrations. Implant angulation affected the stress concentration levels and localizations. CLINICAL IMPLICATIONS. These results will help clinicians understand the mechanical behavior of cement-retained implant-supported crowns during crown retrieval.

Clinical performance and failures of zirconia-based fixed partial dentures: a review literature

  • Triwatana, Premwara;Nagaviroj, Noppavan;Tulapornchai, Chantana
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.76-83
    • /
    • 2012
  • PURPOSE. Zirconia has been used in clinical dentistry for approximately a decade, and there have been several reports regarding the clinical performance and survival rates of zirconia-based restorations. The aim of this article was to review the literatures published from 2000 to 2010 regarding the clinical performance and the causes of failure of zirconia fixed partial dentures (FPDs). MATERIALS AND METHODS. An electronic search of English peer-reviewed dental literatures was performed through PubMed to obtain all the clinical studies focused on the performance of the zirconia FPDs. The electronic search was supplemented by manual searching through the references of the selected articles for possible inclusion of some articles. Randomized controlled clinical trials, longitudinal prospective and retrospective cohort studies were the focuses of this review. Articles that did not focus on the restoration of teeth using zirconia-based restorations were excluded from this review. RESULTS. There have been three studies for the study of zirconia single crowns. The clinical outcome was satisfactory (acceptable) according to the CDA evaluation. There have been 14 studies for the study of zirconia FPDs. The survival rates of zirconia anterior and posterior FPDs ranged between 73.9% - 100% after 2 - 5 years. The causes of failure were veneer fracture, ceramic core fracture, abutment tooth fracture, secondary caries, and restoration dislodgment. CONCLUSION. The overall performance of zirconia FPDs was satisfactory according to either USPHS criteria or CDA evaluations. Fracture resistance of core and veneering ceramics, bonding between core and veneering materials, and marginal discrepancy of zirconia-based restorations were discussed as the causes of failure. Because of its repeated occurrence in many studies, future researches are essentially required to clarify this problem and to reduce the fracture incident.

Effect of various intraoral repair systems on the shear bond strength of composite resin to zirconia

  • Han, In-Hae;Kang, Dong-Wan;Chung, Chae-Heon;Choe, Han-Cheol;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.248-255
    • /
    • 2013
  • PURPOSE. This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS. Thirty zirconia specimens were divided into three groups according to the repair method: Group I-CoJet$^{TM}$ Repair System (3M ESPE) [chairside silica coating with $30{\mu}m$ $SiO_2$ + silanization + adhesive]; Group II-Ceramic Repair System (Ivoclar Vivadent) [etching with 37% phosphoric acid + Zirconia primer + adhesive]; Group III-Signum Zirconia Bond (Heraus) [Signum Zirconia Bond I + Signum Zirconia Bond II]. Composite resin was polymerized on each conditioned specimen. The shear bond strength was tested using a universal testing machine, and fracture sites were examined with FE-SEM. Surface morphology and wettability after surface treatments were examined additionally. The data of bond strengths were statistically analyzed with one-way ANOVA and Tamhane post hoc test (${\alpha}$=.05). RESULTS. Increased surface roughness and the highest wettability value were observed in the CoJet sand treated specimens. The specimens treated with 37% phosphoric acid and Signum Zirconia Bond I did not show any improvement of surface irregularity, and the lowest wettability value were found in 37% phosphoric acid treated specimens. There was no significant difference in the bond strengths between Group I ($7.80{\pm}0.76$ MPa) and III ($8.98{\pm}1.39$ MPa). Group II ($3.21{\pm}0.78$ MPa) showed a significant difference from other groups (P<.05). CONCLUSION. The use of Intraoral silica coating system and the application of Signum Zirconia Bond are effective for increasing the bond strength of composite resin to zirconia.

Application of Targis-Vectris Provisional Restorations for an Oro-Maxillofacial Cancer Patient: A Case report (악성암종 수술 환자에서 임시수복물로서 Targis-Vectris의 응용)

  • Kim, Jin-Man;Han, Jung-Suk;Lee, Sun-Hyung;Yang, Jae-Ho;Lee, Jae-Bong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.113-118
    • /
    • 2002
  • Conventional radiograph, computed tomograph (CT), magnetic resonance image (MRI) are commonly used methods for diagnosis of oro-maxillofacial cancer. MRI is an effective tool to verify soft tissue lesion however, metal produces black artifacts in the image. Therefore, metal structure should be removed before taking MRI to diagnose head and neck cancer patients. A 52-year-old female patient with adenocarcinoma in the posterior right soft palate was referred to take a MRI before surgery. She has 7-unit porcelain fused to metal bridge in the maxilla. Eight-unit Tagis-Vectris fixed partial denture was fabricated to replace her existing PFM bridge to take a MRI without any artifact before and after surgery. The patient satisfied with her restorations in terms of esthetics, function after 11 months. Even though minor staining was detected, Tagis-Vectris restoration fixed partial denture was intact during observation period.

Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion (외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료)

  • Lee, So-Jin;Kim, Yu-Jin;Park, Young-Bum;Cho, Kyoo-Sung;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Surgical extrusion, immediate extrusion following tooth luxation, is a method to preserve one's natural tooth and achieve esthetic restoration without additional periodontal surgery when subgingival dental caries or crown fracture occurs. A 16-year-old male was referred to the clinic from the department of operative dentistry for the esthetic restoration of maxillary left lateral incisor. Due to the crown to root fracture, the tooth was endodontically treated with a buccal crown length of 4 mm. When the palatal flap was elevated, the mesiopalatal cervical fracture area was situated 3-4 mm subgingivally. Crown lengthening was achieved through surgical extrusion. After 3 months of clinical observation and provisional restoration, the maxillary left central incisor was restored with all ceramic crown and obtained a satisfactory clinical result.

An experimental study on hydrothermal degradation of cubic-containing translucent zirconia

  • Kengtanyakich, Santiphab;Peampring, Chaimongkon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.265-272
    • /
    • 2020
  • PURPOSE. The aims of this study were to investigate mechanical properties and hydrothermal degradation behaviour of the cubic-containing translucent yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP). MATERIALS AND METHODS. Four groups of Y-TZP (T, ST, XT, and P), containing different amount of cubic crystal, were examined. Specimens were aged by autoclaving at 122℃ under 2 bar pressure for 8 h. Phase transformation was analyzed using X-ray diffraction (XRD) to measure phase transformation (t→m). Kruskal-Wallis test was used to determine the difference. Surface hardness, biaxial flexural strength, and fracture toughness in values among the experimental groups and verified with Wilcoxon matched pairs test for hardness values and Mann Whitney U for flexural strength and fracture toughness. RESULTS. XRD analysis showed no monoclinic phase in XT and P after aging. Only Group T showed statistically significant decreases in hardness after aging. Hydrothermal aging showed a significant decrease in flexural strength and fracture toughness in group T and ST, while group XT and P showed no effect of aging on fractural strength and fracture toughness with P<.05. CONCLUSION. Hydrothermal aging caused reduction in mechanical properties such as surface hardness, biaxial flexural strength, and fracture toughness of Y-TZP zirconia. However, cubic-containing zirconia (more than 30% by volume of cubic crystal) was assumed to have high resistance to hydrothermal degradation. Clinical significance: Cubic-containing zirconia could withstand the intraoral aging condition. It could be suggested to use as a material for fabrication of esthetic dental restoration.

Porcelain Laminate Veneer Restoration (Porcelain laminate veneer의 수복)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.191-200
    • /
    • 2012
  • The patients' demand for treatment of unesthetic anterior teeth is steadily growing. Accordingly, several treatment options such as porcelain laminate veneers(PLV) have been proposed to restore the esthetic appearance of the dentition. Porcelain laminate veneers are considered minimally invasive, but they also require removal of sound enamel. One critical step in the porcelain laminate veneer technique is the achievement of sufficient ceramic thickness, and several different strategies for tooth preparation can be found in the literature. This clinical report describes a step-by-step protocols for preparation of these restorations used with the silicone index from diagnostic wax-up and the acrylic resin mock-up. Conservative use of porcelain laminate veneers provided satisfactory esthetic outcomes and preserved sound tooth structure.

Characterization of the Stress in the Luting Cement layer Influenced by Material Properties of Full Veneer Crown (전부피개관의 물성과 시멘트의 물성이 시멘트 내부의 응력에 미치는 영향)

  • Lee, Jun-Young;Lee, Kyu-bok;Lee, Chung-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The objective of this study was to test the effects of crown material, cement type, the direction in which stress is applied and distribution of luting cement that might lead to cement microfracture using 2D Finite Element Method. Twenty three finite element models with a chamfer margin configuration were generated for a mandibular first molar. Crown models exhibited four crown materials: type 3 gold alloy, Ni-Cr alloy, ceramic and composite resin, and two luting cements: zinc phosphate and glass ionomer cements with a thicknesses of $70{\mu}m$. Modeled crowns were loaded axially or obliquely at unit load of 1 N. Areas and levels of stress concentrations within the cement were determined. Stress in the cement layer at the margins of crowns were higher than those in the area away from the margin. Stress under oblique loads were much higher than under axial load. The stiffer crown material produced higher stress and similarly, higher stress were found in cements with the greater Young's modulus.