• 제목/요약/키워드: dental ceramic

검색결과 563건 처리시간 0.036초

Hydroxyapatite-Based Biomaterials for Hard Tissue Applications

  • Kim Hae-Won;Kim Hyoun-Ee
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.319-330
    • /
    • 2005
  • Over the past few decades, much effort has been made to improve the mechanical and biological performance of HA, in order to extend its range of applications. As a major inorganic component of human hard tissues, hydroxyapatite bioceramic is regarded as being one of the most biocompatible materials. Numerous in vitro and in vivo studies have confirmed its excellent bioactivity, osteoconductivity and bone forming ability. However, because of its poor mechanical properties, its use in hard tissue applications has been restricted to those areas in which it can be used in the form of small sized powders/granules or in the non-load bearing sites. A number of researchers have focused on improving the mechanical and biological performance of HA, as well as on the formulation of hybrid and composite systems in order to extend its range of applications. In this article, we reviewed our recent works on HA-based biomaterials; i) the strengthening of HA with ceramic oxides, ii) HA-based bioactive coatings on metallic implants, iii) HA-based porous scaffolds and iv) HA-polymer hybrids/composites.

Tensile bond strength of four denture resins to porcelain teeth with different surface treatment

  • El-Sheikh, Mohamed;Powers, John
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.423-427
    • /
    • 2013
  • PURPOSE. This study evaluated the bond strength between porcelain denture teeth (Bioblend 43D) and four different polymerized denture resins (Lucitone 199, Palapress, Acron MC, Triad) with and without a bonding agent and after four different types of surface treatment (polished, HF etched, sandblasted, air-abraded). MATERIALS AND METHODS. Central incisor porcelain denture teeth were divided into 32 groups of 5 each. Tensile bond strength (MPa) was determined using a testing machine at crosshead speed of 0.5 mm/min. Mean and standard deviation are listed. Data were analyzed by two-way ANOVA. Means were compared by Tukey-Kramer intervals at 0.05 significance level. RESULTS. All surface treatment increased bond strength compared to polished surface and the highest bond strength was found with Palapress resin with etched porcelain surface (8.1 MPa). Bonding agent improved the bond strength of all denture resins to porcelain teeth. Superior bonding was found with Palapress and air-abraded porcelain (39 MPa). CONCLUSION. Resins with different curing methods affect the bond strength of porcelain teeth to denture bases. Superior bonding was found with auto-polymerized resin (Palapress). Application of ceramic primer and bonding agent to porcelain teeth with and without surface treatment will improve the bond strength of all denture resins to porcelain teeth.

Cytotoxicity and biocompatibility of high mol% yttria containing zirconia

  • Gulsan Ara Sathi Kazi;Ryo Yamagiwa
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.52.1-52.11
    • /
    • 2020
  • Objectives: Yttria-stabilized tetragonal phase zirconia has been used as a dental restorative material for over a decade. While it is still the strongest and toughest ceramic, its translucency remains as a significant drawback. To overcome this, stabilizing the translucency zirconia to a significant cubic crystalline phase by increasing the yttria content to more than 8 mol% (8YTZP). However, the biocompatibility of a high amount of yttria is still an important topic that needs to be investigated. Materials and Methods: Commercially available 8YTZP plates were used. To enhance cell adhesion, proliferation, and differentiation, the surface of the 8YTZP is sequentially polished with a SiC-coated abrasive paper and surface coating with type I collagen. Fibroblast-like cells L929 used for cell adherence and cell proliferation analysis, and mouse bone marrow-derived mesenchymal stem cells (BMSC) used for cell differentiation analysis. Results: The results revealed that all samples, regardless of the surface treatment, are hydrophilic and showed a strong affinity for water. Even the cell culture results indicate that simple surface polishing and coating can affect cellular behavior by enhancing cell adhesion and proliferation. Both L929 cells and BMSC were nicely adhered to and proliferated in all conditions. Conclusions: The results demonstrate the biocompatibility of the cubic phase zirconia with 8 mol% yttria and suggest that yttria with a higher zirconia content are not toxic to the cells, support a strong adhesion of cells on their surfaces, and promote cell proliferation and differentiation. All these confirm its potential use in tissue engineering.

금속-도재 가공치 하부구조 제작에서 이상적인 형태와 임상에서 사용되는 형태의 차이 분석 (A study on the difference analysis between an ideal and a clinical shape in case of manufacturing a metal-ceramic pontic substructure)

  • 김욱태;임수연
    • 구강회복응용과학지
    • /
    • 제32권1호
    • /
    • pp.8-15
    • /
    • 2016
  • 목적: 본 연구 목적은 임상에서 사용되고 있는 금속-도재 가공치 하부구조물이 적절하게 설계되었는지 판단하고 모양과 크기 및 위치에 따라 발생할 수 있는 문제점을 파악하여 설계 시 기초 원리에 기반하여 제작하는 것을 강조하였다. 연구 재료 및 방법: 금속-도재 가공치 하부구조 제작에서 이상적인 형태와 임상에서 사용되는 형태의 가공치 기저면(P1), 양 인접면(C), 치경연(P2) 및 순면 최대 풍융부위로 올라가는 치경 1/3부위(P3)의 도재 두께를 측정 하여 일원배치 분산분석 및 사후 검정을 수행하였다. 결과: 측정한 부위의 도재 두께를 비교한 결과 각 그룹 간에는 통계적 유의성이 없었다(P > 0.05). 결론: 본 연구에서 제시하는 금속하부 구조물은 가공치가 갖추어야 할 요구요건을 충족하고 있어 임상적으로 사용이 가능하다.

주입성형한 지르코니아 소결체의 기계적 성질에 미치는 알루미나 첨가의 영향 (Effects of the Addition of Alumina on the Mechanical Properties of Cast Zirconia Sintered Body)

  • 이동윤;조준호;서정일;배원태
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.113-119
    • /
    • 2012
  • Purpose: Zirconia blocks for all ceramic dentures are divided into two groups. One is pre-heated block and the other is binder added block. In this study, the possibility of recycling the remained parts of binder added block after CAD/CAM machining with slip casting process was investigated. Methods: Owing to the binder added block contain large amount of organic matter, Binder burn-out was must be carried out before ball milling for preparing the casting slip. Binder burn-out was accomplished at $600^{\circ}C$ for 10 hours. Ball milling was performed with 5mm zirconia ball and 60mm polyethylene bottle. From 0% to 5% at 1% intervals of alumina was added to zirconia powder for preparing slip. Solid casting was achieved with plaster mold. Cast bodies were dried and sintered at $1,500^{\circ}C$ for 1 hour. Linear shrinkage, apparent porosity, water absorption, bulk density, and flexural strength were tested. Microstructures were observed by SEM, EDS and XRD analysis were executed. Results: Optimum slips for casting was prepared with 300g ball, 100g powder, and 180g distilled water. Cast body without alumina showed 26% of linear shrinkage, 6.07 of apparent density, and 470MPa of three point bend strength. On the other hand, as received zirconia block, which was sintered at the same conditions, showed 23% of linear shrinkage, 6.10 of apparent density, and 680MPa of three point bend strength. When 3% of alumina was added to zirconia, sintered body showed 23% of linear shrinkage, 6.10 of apparent density, and 780MPa of three point bend strength. SEM photomicrographs and EDS analysis showed alumina particles uniformly dispersed in zirconia matrix, and XRD analysis showed no phase transformation of tetragonal zirconia particles was occurred when alumina was added. Conclusion: According to the all of this experimental results, 3% of alumina added cast zirconia body showed excellent mechanical properties more than as received binder containing zirconia block.

도재 전용액이 지르코니아 코어-도재 비니어의 전단결합강도에 미치는 영향 (Effect of modeling liquid on the shear-bond strength of zirconia core - porcelain veneer)

  • 최병환;김임선
    • 대한치과기공학회지
    • /
    • 제36권2호
    • /
    • pp.83-89
    • /
    • 2014
  • Purpose: This study is to evaluate the effect of modeling liquid on the shear-bond strength between zirconia core and veneering ceramic. Methods: Disk-shaped (diameter: 12.0mm; height: 3.0mm) zirconia were randomly divided into six groups according to the surface conditioning method and whether modeling liquid is used or not to be applied (N=60, n=10 per group): group 1-control group with distilled water(ZD); group 2-control group with modeling liquid(ZM); group 3-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$(AD) with distilled water; group 4-airborne particle abrasion with $110-{\mu}m$ $Al_2O_3$ with modeling liquid(AM); group 5-liner with distilled water(LD); group $6{\pounds}{\neq}liner$ with modeling liquid(LM). Contact angles were determined by the sessile drop method at room temperature using a contact angle measurement apparatus. The specimens were prepared using dentin veneering ceramics, veneered, 3mm high and 2.8mm in diameter, over the cores. The shear bond strength test was performed in a Shear bond test machine. Load was applied at a cross-head speed of 0.50mm/min until failure. The fractured zirconia surfaces were evaluated by using stereomicroscope (${\times}30$). Collected data were analyzed using SPSS(Statistical Package for Social Sciences) Win 12.0 statistics program. Results: ZD showed the highest contact angle($50.6{\pm}5.4^{\circ}$) and LD showed the lowest value($6.7{\pm}1.3^{\circ}$). Control groups and zirconia liner groups were significantly higher contact angle than liner groups(p<0.05). LD was the highest shear bond strength($43.9{\pm}3.8MPa$) and ZD was the lowest shear bond strength($24.8{\pm}4.9MPa$). Shear bond strengths of control groups and contact angle of liner groups were not significantly different((p>0.05). Liner groups presented adhesive failures. The others groups showed cohesive and adhesive failures. Conclusion: Modeling liquid groups showed lower contact angles and lower shear bond strength compared to those of distilled water groups.

치아용 세라믹스에서의 접촉피로 및 강도저하 (Contact fatigue and strength degradation in dental ceramics)

  • 정연길;이수영;최성철
    • 한국결정성장학회지
    • /
    • 제9권5호
    • /
    • pp.527-533
    • /
    • 1999
  • 치아용 대체재료로 사용되고 있는 세 가지의 세라믹스, 장석질 자기, 운모를 함유한 유리-세라믹 및 유리침윤 알루미나에 대한 접촉피로을 실제 치아의 접촉상황과 유사한 구형입자를 이용한 헤르지안 압입시험법으로 물에서 수행하였으며, 각 재료에서의 접촉손상이 강도에 미치는 영향을 고찰하였다. 초기의 손상형태는 각 재료가 갖는 미세구조에 의존하여 나타났으며, 장석질 자기는 취성거동을 나타내는 cone 형태의 균열이, 운모를 함유한 유리-세라믹은 준-소성 변형 거동을 나타내는 변형이, 그리고 유리침윤 알루미나는 두 재료의 중간거동을 나타내었다. 그러나 반복하중의 수(n=1~n=$10^6$)가 증가됨에 따라 모든 재료에서 급격한 강도저하를 나타내었으며, 파괴는 접촉피로에 의해 형성된 손상에서 일어났다. 일정하중(200N, 500N 및 1000N)에서 반복하중의 수가 증가됨에 따라 두 번의 강도저하가 일어났으며, 첫 번째의 강도저하는 cone 형태의 균열이 주 요인으로 작용되었으며, 두 번째 강도저하는 반복하중에 따른 radial 형태의 균열에 의해 일어났다. 이러한 radial 형태의 균열발생은 각 재료에서 급격한 강도저하를 가져왔으며, 계속적인 반복하중으로 재료의 파괴를 유발시켰다. 반복하중의 수를 고정시킨 수 압입하중의 변화에 따른 강도저하에 대한 고찰을 통해 장석질 자기가 접촉피로에 대한 손상내구성을 갖음을 알 수 있었다.

  • PDF

Alumina와 zirconia가 치과용 코아 도재의 물리적 성질에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF ALUMINA AND ZIRCONIA ON MECHANICAL PROPERTIES OF DENTAL CORE PORCELAIN)

  • 신현수;이상진;이근우
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.317-349
    • /
    • 1993
  • This study investigated the effect of filler particle size and weight% on mechanical properties of dental core porcelain. In alumina, variation in particle size and weight% and in zirconia, variation in weight%, all specimens were tested three-point bending strength, transmittance, thermal expansion coefficient, porosity and shrinkage and observed with SEM and analysed with X-ray diffractometer. In order to develop shrink-free porcelain, after firing alumina only, glass wasinfiltrated. And aluminum was added to alumina with the expanding character of aluminum oxidize into alumina, and was followed by second firing of glass infiltration procedure. Then mechanical properties were observed. The results of this study were obtained as follows. 1. The bending strength of zirconia was higher than that of alumina, and $5{\mu}m$ alumina had highest strength in variation of particle size of alumina. Except for $5{\mu}m$ alumina, increased with weight%, bending strength increased up to 80% and decreased at 90%. In case of glass infiltration, bending strength was slight higher than 80% and 90% of $5{\mu}m$ alumina. 2. Transmittance increased with increase of shrinkage, decrease of porosity, and with increase of filler size and had no direct correlation with weight%. 3. Thermal expansion coefficient of alumina group was $7.42\sim8.64\times10^{-6}/^{\circ}C$ and that of zirconia group was $9.83\sim12.11\times10^{-6}/^{\circ}C$ and the latter was higher than the former. 4. In x-ray diffraction analysis, alumina group and zirconia group increased $Al_2O_3$ peak and $t-ZrO_2$ peak with increase of weight%. The second phase(cristobalite peak) was observed in zirconia 40% group. 5. Porosity of zirconia was lower than that of alumina and $5{\mu}m$ alumina group had many pores with SEM. In case of low filler content, fracture occurred in glass and high filler content, in glass and filler. In case of aluminum addition to alumina, small oxidised aluminum was observed. 6. Zirconia group had high shrinkage than alumina group, and mixed group of alumina group had high shrinkage. In case of glass infiltration, shrinkage decreased and aluminum addition to alumina group was almost shrink-free.

  • PDF

산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향 (Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants)

  • 이한아;석수황;이상혁;임범순
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.257-274
    • /
    • 2018
  • 본 논문에서는 순수 티타늄(cp-Ti) 임플란트를 SLA (Sandblasting with Large grit and Acid) 처리할 때 산-처리 용액의 유형, 산-처리 온도 및 산-처리 시간 등이 티타늄 표면에 주는 영향을 평가하고자 하였다. 원판형의 cp-Ti 시편을 준비하여 표면을 인산칼슘계 세라믹 분말로 RBM (Resorbable Blast Media) 처리하였다. 산-처리 용액으로 염산을 30 vol%로 고정하고 황산의 농도를 10, 20, 30, 35 vol%로 증가시키며 혼합한 용액에 증류수를 추가하여 4종의 산-처리 용액을 준비하였다. 실험군은 4종의 산-처리 용액, 3 종의 처리온도 및 3 종의 처리시간 등 36 가지로 분류하여 실험군당 4개의 시편을 산-처리하였다. 산-처리 전 후 시편 무게를 전자저울로 측정하여 무게 감소비율을 계산하였고, 공초점주사전자현미경으로 표면거칠기를 측정하였다. X-선 회절분석기(XRD)로 XRD 패턴을 측정하였고, 주사전자현미경으로 표면 형상을 관찰하였으며, 에너지 분산형 분석기(EDX)와 광전자분광법(XPS)로 표면성분을 분석하였다. 무게 감소비율과 표면거칠기 측정값은 Tukey-multiple comparison test (p = 0.05)로 통계 분석하여 다음의 결과를 얻었다. 산-처리에 따른 티타늄 시편의 무게 감소는 황산의 농도 및 산-처리 용액의 온도가 높을수록 유의하게 증가하였다. 산-처리한 티타늄의 표면 거칠기는 산-처리 조건(황산 농도, 온도, 시간)에 일정한 영향을 받지 않았다. XRD 분석에서 산-처리한 모든 시편에서 티타늄(${\alpha}-Ti$)과 수소화 티타늄($TiH_2$) 결정상이 관찰되었고, XPS 분석으로 티타늄 표면에 얇은 n산화 티타늄 층이 형성된 것을 알 수 있었다. $90^{\circ}C$ 산-용액에서 처리할 경우 티타늄 표면이 과도하게 용해될 수 있으므로 주의하여야 한다.

심미적 포스트 코어의 종류에 따른 미세누출에 관한 연구 (Microleakage of endodontically treated teeth restored with three different esthetic post and cores)

  • 박지근;박지만;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.53-60
    • /
    • 2009
  • 연구목적: 오늘날 심미적 요구의 증가로 치아색 포스트 코어에 대한 많은 관심이 모아지고 있으며 다양한 연구가 진행 중이다. 현재 화이버 포스트 (ParaPost fiber White, Coltene Whaledent, Cuyahoga Falls, USA), 지르코니아 포스트 (CosmoPost, Ivoclar Vivadent, Schann, Germany) 등에 관한 논문은 다소 나와 있으나 요즘 여러 분야에서 관심을 받고 있는 CAD/CAM (computer-aided design/computer-aided manufacturing) 방식으로 지르코니아를 가공한 절삭형 지르코니아 포스트 코어에 대한 연구는 많지 않은 실정이다. 이 연구의 목적은 CAD/CAM을 이용한 지르코니아를 비롯하여 근관치료된 치아에서 사용된 세 가지 다른 치아색 포스트 코어에 대해 미세누출 (microleakage)을 비교해 보는 것이다. 연구 재료 및 방법: 발치된 건전한 상악 절치 27개를 채택하여 백악법랑질경계 (CEJ)에서 절단하여 근관치료를 시행하고, 세군 (각 9개)으로 나누었다. 각군들은 화이버 포스트와 콤포짓트 레진 코어 (1군), 지르코니아 포스트와 열가압형 세라믹 코어 (2군), CAD/CAM 절삭형 지르코니아 포스트 코어 (3군)로 수복하였다. $5-55^{\circ}C$ 1000회 열순환 처리 (thermocycling)를 시행하고, 2% 메틸렌 블루로 $37^{\circ}C$에서 24시간 염색하였다. 치아장축과 평행하게 순설방향으로 절단하여 미세누출을 현미경과 컴퓨터 프로그램을 사용하여 분석을 하였다. 데이터는 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 모든 군에서 미세누출을 보였으며, 지르코니아 포스트와 열가압형 세라믹 코어군 (2군)에서 치근계면 입구에서는 다소 많은 미세누출을 보였으나 포스트 끝에 이르러서는 거의 미세누출이 없는 결과를 보였다. 화이버 포스트와 콤포짓트 레진 코어군 (1군)과CAD/CAM 절삭형 지르코니아 포스트 코어군 (3군)에서는 부위별로 균등한 미세누출을 보였다. 결론: 화이버 포스트와 콤포짓트 레진 코어군, 지르코니아 포스트와 열가압형 세라믹 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군 모두에서 미세누출을 보였고, 이 중에서 지르코니아 포스트와 열가압형 세라믹 코어군이 좀 더 큰 미세누출에 대한 저항성을 보였으며 화이버 포스트와 콤포짓트 레진 코어군, CAD/CAM 절삭형 지르코니아 포스트 코어군은 유사한 양상을 보였으나, 각 실험군 간에 통계적으로 유의한 차이는 인정되지 않았다. (P>.05)