• Title/Summary/Keyword: dental cements

Search Result 181, Processing Time 0.022 seconds

Comparison of the post cementation efficacy using different cements and methods (포스트 접착 시멘트의 종류와 적용 방법에 따른 접착 효율 비교)

  • Cho, Ok-In;Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.48 no.9
    • /
    • pp.680-687
    • /
    • 2010
  • The purpose of this study was to compare post cementation efficacy according to the different adhesive systems and cement delivery methods. A total of 40 extracted human single-rooted premolar teeth were randomly divided in four groups according to the two luting agents of Unicem applicap (3M ESPE, St. Paul, MN, USA) or Variolink II (Ivoclar Vivadent, Liechtenstein) and cement delivery methods of direct cement application or lentulo spiral application. After restoration using glass?fiber posts, the samples were embedded in acrylic resin. Three sections of 2 mm thickness were prepared from each specimen, and the post in each section was subjected to a push-out test. The data were analysed statistically at significant level of 95%. The Unicem had significantly higher push-out bond strength than Variolink and the lentulo spiral application made higher bond strength (p<0.05). Adhesive failure between cement and dentin was predominant in all groups. The Unicem of self-etch system and cement delivery using lentulo spiral showed clinically acceptable and comparable bonding strength for the fiber post.

Microtensile bond strength of resin cement primer containing nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) to human dentin

  • Arjmand, Nushin;Boruziniat, Alireza;Zakeri, Majid;Mohammadipour, Hamideh Sadat
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2018
  • PURPOSE. The purpose of the current study was to evaluate the effect of incorporating nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) into a self-etching primer of a resin cement on the microtensile bond strength of dentin, regarding the proven antibacterial feature of NAg and remineralizing effect of NACP. MATERIALS AND METHODS. Flat, mid-coronal dentin from 20 intact extracted human third molars were prepared for cementation using Panavia F2.0 cement. The teeth were randomly divided into the four test groups (n=5) according to the experimental cement primer composition: cement primer without change (control group), primer with 1% (wt) of NACP, primer with 1% (wt) of physical mixture of NACP+Nag, and primer with 1% (wt) of chemical mixture of NACP+Nag. The resin cement was used according to the manufacturer's instructions. After storage in distilled water at $37^{\circ}C$ for 24 h, the bonded samples were sectioned longitudinally to produce $1.0{\times}1.0mm$ beams for micro-tensile bond strength testing in a universal testing machine. Failure modes at the dentin-resin interface were observed using a stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's post-hoc tests and the level of significance was set at 0.05. RESULTS. The lowest mean microtensile bond strength was obtained for the NACP group. Tukey's test showed that the bond strength of the control group was significantly higher than those of the other experimental groups, except for group 4 (chemical mixture of NACP and NAg; P=.67). CONCLUSION. Novel chemical incorporation of NAg-NACP into the self-etching primer of resin cement does not compromise the dentin bond strength.

A STUDY ON THE SHEAR BOND STRENGTH OF ESTHETIC RESTORATIVE MATERIALS TO DENTAL AMALGAM (아말감과 심미성 수복재료와의 전단 결합강도에 관한 연구)

  • Jeong, Hye-Jeon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.129-141
    • /
    • 1995
  • Composite resin and glass-ionomer cement can be used for the purpose of repair of defective amalgam restoration. The purpose of this study was to evaluate of shear bond strength of esthetic restorative materials to dental amalgam. The materials used in this study were Photo Clearfil Bright(light curing composite resin), Clearfil F II(chemical curing composite resin), Fuji II LC(light curing glass-ionomer cement), Fuji II (chemical curing glass-ionomer cement), All-Bond 2(intermediary), and Scotchbond Multi-Purpose (intermediary). A total of 120 acrylic cylinders with amalgam were divided into 8 groups After amalgam condensation, all specimens were stored for 48 hours in water at $37^{\circ}C$ and tested with Instron universal testing machine between amalgam and composite resins and glass-ionomer cements. The data were analyzes statiscally by ANOVA and Duncan test. The following results obtained ; 1. The shear bond strength of bonded composite resin to amalgam was higher than bonded glass-ionomer cement(P<.001). 2. The group 4 had highest shear bond strength with 15.45kgf/$cm^2$ and the group 5 had lowest shear bond strenght with 3.26kgf/$cm^2$(P<.001). 3. In the group 3, 4, 5, 6, the group 3, 4 with All-Bond 2 had higher shear bond strength than the group 5, 6 with Scotch bond MP both in light-curing and in chemical curing. 4. Both in composite resin and glass-ionomer cement, chemical curing materials had higher shear bond stength than light curing materials(P<.001).

  • PDF

A STUDY ON THE BOND STRENGTHS OF LIGHT-CURING GLASS IONOMER CEMENTS TO DENTAL AMALGAM (광중합 Glass Ionomer Cement와 Amalgam의 결합강도에 관한 연구)

  • Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.357-364
    • /
    • 1996
  • The purpose of this study was to asses the shear bond strengths of 3 types of light-curing Glass Ionomer cement to dental amalgam with or without an intermediary agent. 60 amalgam adherent specimens were prepared and aged in water at $37^{\circ}C$ for 3 days. Before bonding, the amalgam surfaces were finished flat on 600-grit silicon carbide paper. 30 specimens among 60 were used for bonding in this condition, and the other 30 were covered with a thin layer of light-curing intermediary agent. Shear bond strengths were measured with universal testing machine (Instron, Model 4301) and statistically processed by ANOVA and t-test. On completion of bond test, the fracture surfaces were examined under light microscope so that the mode of bond failure could be assessed The results were as follows : 1. Bond strength of Fuji II LC group showed the hightest value and was followed by Vitremer, Vitrebond groups (p<0.05). 2. The bond strengths achieved without an intermediary agent were higher than those obtained with intermediary agent (p<0.05). 3. For the specimens bonded with intermediary agent, bond failures occured mostly at the agent-amalgam interface. So, the use of intermediary bonding agent was thought not recommendable at glass ionomer-amalgam interface.

  • PDF

Bonding values of two contemporary ceramic inlay materials to dentin following simulated aging

  • Khalil, Ashraf Abdelfattah;Abdelaziz, Khalid Mohamed
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.446-453
    • /
    • 2015
  • PURPOSE. To compare the push-out bond strength of feldspar and zirconia-based ceramic inlays bonded to dentin with different resin cements following simulated aging. MATERIALS AND METHODS. Occlusal cavities in 80 extracted molars were restored in 2 groups (n=40) with CAD/CAM feldspar (Vitablocs Trilux forte) (FP) and zirconia-based (Ceramill Zi) (ZR) ceramic inlays. The fabricated inlays were luted in 2 subgroups (n=20) with either etch-and-bond (RelyX Ultimate Clicker) (EB) or self-adhesive (RelyX Unicem Aplicap) (SA) resin cement. Ten inlays in each subgroup were subjected to 3,500 thermal cycles and 24,000 loading cycles, while the other 10 served as control. Horizontal 3 mm thick specimens were cut out of the restored teeth for push out bond strength testing. Bond strength data were statistically analyzed using 1-way ANOVA and Tukey's comparisons at ${\alpha}=.05$. The mode of ceramic-cement-dentin bond failure for each specimen was also assessed. RESULTS. No statistically significant differences were noticed between FP and ZR bond strength to dentin in all subgroups (ANOVA, P=.05113). No differences were noticed between EB and SA (Tukey's, P>.05) bonded to either type of ceramics. Both adhesive and mixed modes of bond failure were dominant for non-aged inlays. Simulated aging had no significant effect on bond strength values (Tukey's, P>.05) of all ceramic-cement combinations although the adhesive mode of bond failure became more common (60-80%) in aged inlays. CONCLUSION. The suggested cement-ceramic combinations offer comparable bonding performance to dentin substrate either before or after simulated aging that seems to have no adverse effect on the achieved bond.

Evaluation of the Changes in Polymerization of TheraCal LC with Various Light-curing Time and Distance (광중합 시간과 거리의 변화에 따른 TheraCal LC의 중합도 평가)

  • Bae, Sangyong;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.392-399
    • /
    • 2019
  • The purpose of this study was to evaluate polymerization of TheraCal LC, one of the tricalcium silicate cements. To measure the Vickers hardness number (VHN), the specimens were cured at different light curing time and distance. As a result, the VHN of the upper surface was significantly higher than the lower surface's in all groups (p < 0.05). The VHN of the lower surface was increased significantly with the increase of the light curing time in all distance (p < 0.05). When the distance was more than 4.0 mm at all light curing time, the VHN of lower surface was significantly decreased (p < 0.05). When the specimen was light cured for 20 seconds, the VHN of the lower surface did not exceed 2, which corresponds to 10% of the upper surface's. These results suggested that the 20 second light curing time was not sufficient to polymerize the lower surface under specific conditions and that light-curing time should be increased.

Effects of the exposure site on histological pulpal responses after direct capping with 2 calcium-silicate based cements in a rat model

  • Trongkij, Panruethai;Sutimuntanakul, Supachai;Lapthanasupkul, Puangwan;Chaimanakarn, Chitpol;Wong, Rebecca;Banomyong, Danuchit
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.36.1-36.12
    • /
    • 2018
  • Objectives: Direct pulp capping is a treatment for mechanically exposed pulp in which a biocompatible capping material is used to preserve pulpal vitality. Biocompatibility tests in animal studies have used a variety of experimental protocols, particularly with regard to the exposure site. In this study, pulp exposure on the occlusal and mesial surfaces of molar teeth was investigated in a rat model. Materials and Methods: A total of 58 maxillary first molars of Wistar rats were used. Forty molars were mechanically exposed and randomly assigned according to 3 factors: 1) the exposure site (occlusal or mesial), 2) the pulp-capping material (ProRoot White MTA or Bio-MA), and 3) 2 follow-up periods (1 day or 7 days) (n = 5 each). The pulp of 6 intact molars served as negative controls. The pulp of 12 molars was exposed without a capping material (n = 3 per exposure site for each period) and served as positive controls. Inflammatory cell infiltration and reparative dentin formation were histologically evaluated at 1 and 7 days using grading scores. Results: At 1 day, localized mild inflammation was detected in most teeth in all experimental groups. At 7 days, continuous/discontinuous calcified bridges were formed at exposure sites with no or few inflammatory cells. No significant differences in pulpal response according to the exposure site or calcium-silicate cement were observed. Conclusions: The location of the exposure site had no effect on rat pulpal healing. However, mesial exposures could be performed easily, with more consistent results. The pulpal responses were not significantly different between the 2 capping materials.

Six-year clinical performance of lithium disilicate glass-ceramic CAD-CAM versus metal-ceramic crowns

  • Ahmed Aziz;Omar El-Mowafy
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.44-54
    • /
    • 2023
  • PURPOSE. To assess the clinical performance of monolithic CAD-CAM lithium disilicate glass-ceramic (LDGC) crowns and metal-ceramic (MC) crowns provided by predoctoral students. This study also assessed the effects of patient and provider-related factors on their clinical performance as well as patient preference for these types of crowns. MATERIALS AND METHODS. Twenty-five patients who received 50 crowns (25 LDGC CAD-CAM and 25 MC) provided by predoctoral students were retrospectively examined. LDGC CAD-CAM crowns were milled in-house using the CEREC Bluecam system and cemented with either RelyX Unicem or Calibra Esthetic resin cements. MC crowns were cemented with RelyX Unicem cement. Clinical assessment of the crowns and the supporting periodontal structures were performed following the modified California Dental Association (CDA) criteria. Patients' preference was recorded using a visual analog scale (VAS). The results were statistically analyzed using log-rank test, Pearson Chi-squared test and Kaplan-Meier survival analysis. RESULTS. Twelve complications were observed in the MC crown group (9-esthetic, 2-technical and 1-biological). In comparison, 2 complications in the LDGC CAD-CAM crown group were observed (1-technical and 1-esthetic). The 6-year cumulative survival rates for MC crowns and LDGC CAD-CAM were 90.8% and 96%, respectively, whereas the success rates were 83.4% and 96%, respectively. Overall, patients preferred the esthetic outcomes of LDGC CAD-CAM crowns over MC crowns. CONCLUSION. The high survival and success rates, low number of complications, and the high level of patients' acceptance of monolithic LDGC CAD-CAM crowns lend them well as predictable and viable alternatives to the "gold standard" MC crowns.

Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

  • Laura Vitoria Rizzatto;Daniel Meneghetti;Marielle Di Domenico;Julia Cadorin Facenda;Katia Raquel Weber;Pedro Henrique Corazza;Marcia Borba
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.136-144
    • /
    • 2023
  • PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging. MATERIALS AND METHODS. A polymer-infiltrated ceramic network (PICN) and a nanoceramic resin (RNC) were used to produce the specimens. Two types of dual-cure resin cements, a self-adhesive and a universal, were investigated. Bilayer specimens were produced (n = 10) and aged for 6 months in a humid environment before the biaxial flexural strength test (σf). Bonded specimens were subjected to a mechanical aging protocol (50 N, 2 Hz, 37℃ water, 500,000 cycles) before the compressive load test (Lf). σf and Lf data were analyzed using two-way ANOVA and Tukey tests (α = .05). Chi-square test was used to analyze the relationship between failure mode and experimental group (α = .05). RESULTS. The type of resin cement and the interaction between factors had no effect on the σf and Lf of the specimens, while the type of restorative material was significant. RNC had higher σf and Lf than PICN. There was a significant association among the type of cracks identified for specimens tested in Lf and the restorative material. CONCLUSION. The type of resin cement had no effect on the flexural strength and load to fracture of the two investigated CAD-CAM chairside materials after aging.

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF