• Title/Summary/Keyword: dental Lab.

Search Result 305, Processing Time 0.026 seconds

Impacts of Sociocultural Factors on Smoking among Disabled People (장애인의 흡연에 영향을 미치는 요인분석)

  • Young-Ran Yeun;Dong-il Chun;Yi Sub Kwak;Hye-Young Kim
    • Journal of Life Science
    • /
    • v.33 no.12
    • /
    • pp.1046-1051
    • /
    • 2023
  • Cigarette smoking is one of the major causes of preventable diseases, disability, and death in Korea and worldwide. It has been clearly linked to the most common causes of death among the elderly and contributes to morbidity and disability associated with many chronic illnesses that are common in this age group. The health benefits of smoking cessation for the elderly have been clearly demonstrated. However, few studies have analyzed the relationship between health and smoking by considering the following many factors, especially among disabled people. In this study, we discuss the impacts of many factors on smoking among disabled people. Adults with disabilities are more likely to smoke than their peers. Public health agencies and practitioners should consider what reasonable adjustments may need to be made to policies and interventions to ensure that they are effective for adults with disabilities.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.

Influences of Unilateral Mandibular Block Anesthesia on Motor Speech Abilities (편측 하악전달마취가 운동구어능력에 미치는 영향)

  • Yang, Seung-Jae;Seo, In-Hyo;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • There exist patients complaining speech problem due to dysesthesia or anesthesia following dental surgical procedure accompanied by local anesthesia in clinical setting. However, it is not clear whether sensory problems in orofacial region may have an influence on motor speech abilities. The purpose of this study was to investigate whether transitory sensory impairment of mandibular nerve by local anesthesia may influence on the motor speech abilities and thus to evaluate possibility of distorted motor speech abilities due to dysesthesia of mandibular nerve. The subjects in this study consisted of 7 men and 3 women, whose right inferior alveolar nerve, lingual nerve and long buccal nerve was anesthetized by 1.8 mL lidocaine containing 1:100,000 epinephrine. All the subjects were instructed to self estimate degree of anesthesia on the affected region and speech discomfort with VAS before anesthesia, 30 seconds, 30, 60, 90, 120 and 150 minutes after anesthesia. In order to evaluate speech problems objectively, the words and sentences suggested to be read for testing speech speed, diadochokinetic rate, intonation, tremor and articulation were recorded according to the time and evaluated using a Computerized Speech $Lab^{(R)}$. Articulation was evaluated by a speech language clinician. The results of this study indicated that subjective discomfort of speech and depth of anesthesia was increased with time until 60 minutes after anesthesia and then decreased. Degree of subjective speech discomfort was correlated with depth of anesthesia self estimated by each subject. On the while, there was no significant difference in objective assessment item including speech speed, diadochokinetic rate, intonation and tremor. There was no change in articulation related with anesthesia. Based on the results of this study, it is not thought that sensory impairment of unilateral mandibular nerve deteriorates motor speech abilities in spite of individual's complaint of speech discomfort.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

The evaluation of clinical efficacy and longevity of home bleaching without combined application of In-office bleaching (자가미백술 단독사용시 임상적 효능 및 유지력 평가)

  • Shin, Byunk-Gyu;Yang, Sung-Eun
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.387-394
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate the whitening efficacy and longevity of home bleaching. Materials and Methods: A total of 28 patients were divided into either experimental group (Opalescence F; 15% carbamide peroxide) or control group randomly. The patients in experimental group were instructed to wear individual trays applied with bleaching gel for 2 hours a day for 4 weeks. Any treatments weren't applied to the patients in control group. The color measurements of central incisors, lateral incisors & canines of upper and lower arch were recorded at base line, immediately after the finishment of treatmemt (4 weeks), 8 weeks and 12 weeks using Colorimeter (Chroma Meter, 2600d Konica Minolta co.) and Vitapan classical shade guide (Vita Zahnfabrik). Results: A significantly stronger color change was observed for overall teeth samples in experimental group immediately after treatment (at 4 weeks) compared to ones in control group (p < 0.05). There was also a significant difference between baseline and 8 weeks or 12 weeks separately though color rebouncing phenomenon occurred as time went by (p < 0.05). Conclusions: The clinical effecacy and longevity of home bleaching without combined application of in-office bleaching was observed through this experiment.