• Title/Summary/Keyword: dental Implant

Search Result 2,755, Processing Time 0.033 seconds

Effectiveness of en-masse retraction using midpalatal miniscrews and a modified transpalatal arch: Treatment duration and dentoskeletal changes

  • Lee, Jungkil;Miyazawa, Ken;Tabuchi, Masako;Sato, Takuma;Kawaguchi, Misuzu;Goto, Shigemi
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.88-95
    • /
    • 2014
  • Objective: The purpose of this study was to compare the treatment duration and dentoskeletal changes between two different anchorage systems used to treat maxillary dentoalveolar protrusion and to examine the effectiveness of en-masse retraction using two miniscrews placed in the midpalatal suture. Methods: Fifty-seven patients (9 men, 48 women), who had undergone level anchorage system treatment at Aichi-Gakuin University Dental Hospital (Nagoya, Japan) were divided into two groups according to the method of maxillary posterior anchorage reinforcement: midpalatal miniscrews (25 patients, mean age 22 years) and conventional anchorage (32 patients, mean age 19 years). The en-masse retraction period, overall treatment duration, pre-treatment effective ANB angle, and change in the effective ANB angle were compared with an independent-samples t -test. Results: Compared to the headgear group, the duration of en-masse retraction was longer by approximately 4 months in the miniscrew group (p < 0.001). However, we found no significant difference in the total treatment duration between the groups. Moreover, a greater change in the effective ANB angle was observed in patients treated with miniscrews than in those treated with the conventional method (p < 0.05). Conclusions: The level anchorage system treatment using miniscrews placed in the midpalatal area will allow orthodontists more time to control the anterior teeth during en-masse retraction, without increasing the total treatment duration. Furthermore, it achieves better dentoskeletal control than does the conventional anchorage method, thereby improving the quality of the treatment results.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

IgG subclass-dependent Recognition of Porphyromonas Gingivalis Antigens in the Early-onset Periodontitis (조기발병형 치주염환자의 IgG subclass 별 Porphyromonas gingivalis 항원인지에 대한 연구)

  • Choi, Jeom-Il;Yoshimobu, Fuminobu;Schifferle, Robert E.;Okuda, Katsuji
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.953-964
    • /
    • 1999
  • 본 연구는 세 종류의 Porphyromonas gingivalis(Pg) antigen의 IgG subclass associated recognition을 평가하기 위해 수행했었다. 총 35명의 조기발병형치주질환자중, Pg381에 대한 IgG2항체의 증가를 보이는 5명이 급속진 행형 치주질환자, IgG4의 증가를 보이는 6명의 환자(국소유년형 치주질환자 2명과 급속진행 형 치주질환자 4명), IgG2+4의 증가를 보이는 2명의 급속진행형 치주질환자 그리고 IgG1+2+4의 증가를 보이는 8명의 환자(국소 유년형 치주질환자 2명과 급속진행형 치주질환자 6명)으로 구성된 21명의 환자를 dot immunoblot analysis를 위해 선택했다. 실험에 사용된 정제된 항원은 Pg381에서 추출한 43-kd fimbrilin protein과 lipoplysaccharide(LPS), Pg A7A1-28(ATCC 53977)에서 추출한 capsularpolysaccharide(CPS)였다. Immunoblotting pattern은 IgG4 antibody가 fimbrial antigen에 강력히 반응함을 보여주었다. Fimbriae에 잘 반응하는 몇몇의 IgG4 antibody역시 antigen에 대해 양성반응을 보였다. 대조적으로 IgG2는 CPS antigen을 일차적으로 인식했다. 전부는 아니지만 대부분의 경우, single이나 group화된 IgG subclass는 모두 LPS antigen을 인식하지 못했다. 같은 group에서 염색강도의 개인적인 차이는 증명되었다. 이런 결과는 조기발 병형 치주질환에서 Pg의 fimbriae와 CPS가 immunodominant antigen이 될 수 있음을 제시한다. 더욱이 IgG subclass antibody가 이런 Pg의 immunoglobulin antigen을 선택적으로 인식함을 알았고, 이는 조기발병형치주질환의 병리에 immunodominant antigen과 함께 IgG의 기능적인 역할을 고려해야 함을 제시한다.

  • PDF

Clinical study on the maxillofacial prosthodontic treatment using dental implant: Part I-Color stability of maxillofacial elastomeric materials (치과용 임플란트를 이용한 악안면 보철치료에 관한 임상적 연구 1부-악안면보철용 실리콘의 색안정성)

  • Jin, Tai-Ho;Bowley, John F.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.379-388
    • /
    • 1998
  • 본 연구는 악안면보철용 실리콘의 색안정성을 연구하기 위하여 실리콘 재료로 MDX 4-4210 Silicone(Dow Coming. Midland, Mich.)과 A-2186(Factor II, Lakeside, Az)을 사용하고 Mars Violet. Golden Yellow, Red yellow, Raw Sienna등 4종의 색소(Factor II, Lakeside, Az)를 이용하여 시편을 제작한 후 1군은 섭씨5-55도에서 700회 thermocycling하였고, 2군은 10%의 비눗물(Ivory, Proctor & Gamble Inc,. Toronto, Ontario)에 담아 섭씨15-55도에서 700회 thermocycling하였다. 3군은 10%의 비눗물에 담아 75일간 실온에서 보관하였으며 4군은 실온의 암실에 75일간 보관하였다. 5군은 초여름인 6월 중순부터 75일간 햇볕이 잘드는 곳에 위치하였다. 이를 측색색차계(Model TC-6FX, Tokyo Denshoku Co., Japan)를 이용하여 측정하고 색변화를 연구한 결과 다음과 같은 결론을 얻었다. 1. $L^*$값의 경우 모든 실험군에서 대조군에 비해 유의하게 감소하였다. 2. $a^*$값의 경우 대부분의 실험군에서 증가하였으나 Raw sienna, Mars violet색소를 사용한 실험 3.4.5군의 MDX4-4210의 경우 감소하는 경향을 보였다. 3. $b^*$값은 실험1.2.3군의 경우 대부분 감소하였고 실험4.5.군의 경우에서 증가하였으나 3.4.5군의 경우에서 대부분 유의한 차이가 없었다. 4. ${\Delta}E$의 값은 실험군에서 대부분 감소하였으나 4군의 A-2186에서 증가하는 경향을 보였고 실험2군의 Red yellow, Mars violet을 사용한 MDX4-4210에서 비교적 큰 변화를 보였다. 5. $L^{\ast}$값과 a값의 변화량의 합은 A-2186의 경우에서 크게 나타났으나 ${\Delta}E$값의 변화량은 MDX4-4210에서 크게 나타났다. 6. $L^*$값의 변화량의 합은 실험4군에서 크게 나타났으며 $a^*$값은 1군에서, $b^*$값과 ${\Delta}E$값의 변화량의 합은 2군에서 크게 나타났다.

  • PDF

Association between periodontal disease and coronary heart disease (치주질환과 관상동맥질환의 관련성에 대한 임상적 연구)

  • Lee, Jun-Ho;Chung, Hyun-Ju;Kim, Ju-Han
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.111-121
    • /
    • 2005
  • Coronary heart disease is the leading cause of mortality in adult population. Whereas the association between periodontal disease and coronary heart disease (CHD) are controversial, recent studies reported the association between periodontal disease and acute myocardial infarction or prognosis of CHD. This study was aimed to investigate the relationship between periodontal disease and angiographically defined CHD, and acute myocardial infarction, and the prognosis of treated CHD. Patients under the age of 60 who had undergone the diagnostic coronary angiography were enrolled in this study, Subjects were classified as positive CHD (+CHD, n=37) with coronary artery stenosis more than 50% in at least one of major epicardial arteries, and negative CHD (-CHD, n=20) without stenosis. After recording the number of missing teeth, periodontal disease status was measured by means of plaque index (PI), gingival index (GI), bleeding on probing (BOP), probing depth (PD), and clinical attachment level (CAL), Positive CHD subjects were classified into acute myocardial infarction group (AMI), and non-AMI with angina pectoris and old myocardial infarction. Six months postoperatively, positive CHD subjects were followed and had undergone the coronary angiography again. Even though there was no significant difference in the periodontal parameters and status between positive CHD and negative CHD, some periodontal parameters, such as mean probing depth and proportion of sites with probing depth greater than 4mm or 6mm were significantly different between AMI and Non-AMI(p<0.05). There was no significant difference in the periodontal parameters according to in angiographically follow-up status. These results indicate that periodontal disease may be associated with the occurrence of acute myocardial infarction.

Material Characteristics of Ti-6Al-4V Alloy Manufactured by Electron Beam Melting for Orthopedic Implants (전자빔 용해 방법으로 제조된 정형외과 임플란트용 Ti-6Al-4V 합금의 재료 특성 분석)

  • Gang, Gwan-Su;Jeong, Yong-Hun;Jang, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;U, Su-Heon;Park, Tae-Hyeon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.25-25
    • /
    • 2018
  • Electron beam melting (EBM) is one of powder based additive manufacturing technology used to produce parts for high geometrical complexity and directly with three-dimensional computer aided design (CAD) model. It is kind of the most promising methods with additive manufacturing for a wide range of medical applications, such as orthopedic, dental implant, and etc. This research has been investigated the microstructure and mechanical properties of as fabricated and hot iso-static pressing (HIP) processed specimens, which are made by an Arcam A1 EBM system. The Ti-6Al-4V titanium alloy powder was used as a material for the 3 dimensional printing specimens. Mechanical properties were conducted with EBM manufacturing and computer numerical control (CNC) machining specimens, respectively. Surface morphological analysis was conducted by scanning electron microscopy (SEM) for their surface, dissected plan, and fractured surface after tensile test. The mechanical properties were included tensile stress-strain and nano-indentation test as a analysis level between nano and macro. As following highlighted results, the stress-strain curves on elastic region were almost similar between as fabricated and HIP processed while the ductile (plastic deformed region) properties were higher with HIP than that of as fabricated processed.

  • PDF

Clinical Effect of MS Coat and Elmex gel on the Dentin Hypersensitivity following Periodontal Surgery (치주수술 후 지각과민증에 대한 MS Coat와 엘멕스 겔처치의 임상적 효과)

  • Park, Sung-Min;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.727-736
    • /
    • 2001
  • Dentinal hypersensitivity is one of the complicated symptom rather than a disease. It has special reaction or pain over uncovered root by heat, mechanical or chemical stimulations, which are normal with healthy teeth, The purpose of this study is to discover rather MS Coat (oxalate-containing pre-polymerized resin suspension) or Elmex gel(amine fluoride+sodium fluoride) is effective on hypersensitivity after periodontal treatment using NRS(Numerica1 Rating Scales), which it is useful for evaluating pain level. This study has been prepared in Dankook Dental Hospital with generally healthy adult who had been suffered from dentinal hypersensitivity after periodontal treatment. Divided in three groups with saline(control group), MS Coat(test 1 group) and Elmex gel(test 2 group). And then, following evaluations were made at the end of 1 minute, 1 week, 1 month and 3 months. 1. The sequence of higher frequency & severeness of hypersensitivity is water within $7^{\circ}C$, air stream & explorer. 2. As time goes on, 1 minute, 1 week, 1 month & 3 months, severeness of hypersensitivity scored lower with water, air stream and explorer. 3. With explorer, the differences among three groups as time had to seen. 4. With air stream, the sensitivity scored lower after 1min with MS Coat, Elmex, and saline sequence. As time goes on the sensitivity was lower with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. 5. With water in $7^{\circ}C$, the sensitivity was much decreasing with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. As the result, MS Coat and Elmex are effective on hypersensitivity caused by periodontal treatment.

  • PDF

Effects of adjunctive daily phototherapy on chronic periodontitis: a randomized single-blind controlled trial

  • Jung, Gyu-Un;Kim, Jin-Woo;Kim, Sun-Jong;Pang, Eun-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.6
    • /
    • pp.280-287
    • /
    • 2014
  • Purpose: The purpose of this randomized single-blind controlled trial was to elucidate the clinical and antimicrobial effects of daily phototherapy (PT) as an adjunct to scaling and root planing (SRP) in patients with chronic periodontitis. Methods: The study was conducted from December 2013 to May 2014 at Ewha Womans University Mokdong Hospital, Seoul, Korea. Forty-one patients with mild to moderate chronic periodontitis were randomly divided into two therapeutic groups in a 1:1 ratio: SRP+PT and SRP (control) groups. All participants underwent full-mouth SRP. PT was performed thrice a day for a month by using electric toothbrushes with embedded light-emitting diodes. Plaque index, gingival index, probing pocket depth (PPD), clinical attachment level (CAL), and bleeding on probing were assessed before (baseline) and four weeks after (follow-up) the treatment. Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, Prevotella intermedia, Fusobacterium nucleatum, Parvimonas micra, Campylobacter rectus, Eikenella corrodens, Streptococcus mutans, and Streptococcus sobrinus levels were detected by a real-time polymerase chain reaction at the same points in time. Results: The clinical parameters improved in both the groups. At the follow-up assessment, PPD was significantly decreased in the SRP+PT group (P=0.00). Further, PPD and CAL showed significantly greater changes in the SRP+PT group than in the SRP group (PPD, P=0.03; CAL, P=0.04). P. gingivalis and T. forsythia levels decreased in this group, but no significant intergroup differences were noted. Conclusions: Adjunctive PT seems to have clinical benefits, but evidence of its antimicrobial effects is not sufficient. Long-term studies are necessary to develop the most effective PT protocol and compare the effectiveness of PT with and without exogenous photosensitizers.

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro (압전방식 초음파 치석제거기의 작업조건에 따른 치과주조용 합금의 삭제에 관한 연구)

  • Cha, Kuk-Bong;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.139-148
    • /
    • 2009
  • Purpose: Ultrasonic scalers have been widely used for removing biofilm which is considered as major etiologic factor of periodontal disease. The purpose of this study was to evaluate the effect of working parameters of piezoeletric ultrasonic scaler with scaler tip (No. 1 tip) on casting gold alloy removal. Methods: Type III dental casting gold alloy (Firmilay$^{circledR}$, Jelenko Inc, CA, USA) was used as substitute for tooth substance. Piezoeletric ultrasonic scaler and No.1 scaler tip (P-Max$^{circledR}$, Satelec, France) were selected. The selected working parameters were mode (P mode, S mode), power setting (2, 4, 8) and lateral force (0.5 N, 1.0 N, 2.0 N). The effect of working parameters was evaluated in terms of ablation depth, ablation width and ablation area. Results: Mode influenced ablation depth and ablation area. Power also influenced ablation depth and ablation area. Especially, Power 2 and power 8 showed statistically significant difference. Lateral force had influence on ablation width, and 0.5 N resulted significant increase compared with 1.0 N and 2.0 N. Ablation depth was influenced by mode, power and lateral force and defect width was influenced by lateral force. Ablation area was influenced by mode and power. Conclusions: It can be concluded that the use of piezoelectric ultrasonic scaler with No. 1 scaler tip in S mode and high power may result in significant loss of tooth substance.

Antioxidant profile of whole saliva after scaling and root planing in periodontal disease

  • Kim, Sang-Chul;Kim, Ok-Su;Kim, Ok-Joon;Kim, Young-Joon;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.4
    • /
    • pp.164-171
    • /
    • 2010
  • Purpose: This study compared the total antioxidant status (TAS) and superoxide dismutase (SOD) activity in the saliva of periodontally compromised patients before and after scaling and root planing (SRP) to assess their diagnostic utility. Methods: Severe chronic periodontitis patient (test group) and subjects with no attachment loss, sites showing a 3 mm or more probing depth and a sulcus bleeding index < 10% (control group) were enrolled in this study. Saliva sampling and clinical examination were performed at one week, one month and 3 months after SRP. The TAS and SOD activity in each patient's saliva was measured for the comparative analysis between the groups. Results: In the test group, the TAS decreased directly after SRP. With time, it increased slightly and was relatively unchanged compared to the baseline. In the control group, the TAS also decreased immediately after SRP but increased gradually with time until 3 months. The SOD activity in the test and control subjects decreased immediately after SRP until 1 month. At 3 months, the SOD activity had increased. Both groups had a similar profile of SOD activity. However, the SOD activity of the control group was significantly higher than that of the test group at each point in time (P < 0.05). Conclusions: There was a significant difference in the total salivary antioxidant level between the periodontitis and healthy or gingivitis (control) group during the experiment period. The total antioxidant level in the saliva was higher in the patients with severe chronic periodontitis than the healthy or gingivitis control before SRP. The SOD activity of the periodontitis patients was lower than the control at each time point. These findings conclusively reveal the possible use of saliva as a diagnostic tool for periodontal health.