• Title/Summary/Keyword: density index

Search Result 1,932, Processing Time 0.032 seconds

Effects of Korean Traditional Dance Exercise of Physical Health, Self-efficacy & Stress in elderly women (우리춤 체조가 여성노인의 신체적 건강, 자기효능감 및 스트레스에 미치는 영향)

  • Kim, Ran;Park, In-Soon;Park, Myung-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.69-79
    • /
    • 2009
  • The purpose of this study was to identify the effect of Korean traditional dance exercise on physical health (BMI; body mass index, BP; blood pressure, VC; vital capacity, TC; total cholesterol, HDL; high-density lipoprotein, TG; triglyceride), self-efficacy and stress in elderly women. A quasi-experimental research design(one group pretest and posttest) was used for this study. Participants were recruited in a metropolitan city and a total of 43 community dwelling elderly women completed the 12-week Korean traditional dance exercise program. Descriptive statistics and paired t-tests were used in the data analysis by SPSS/WIN 12.0. After the Korean traditional dance exercise program there was a significant difference in BMI, VC, TC, HDL, stress and self-efficacy. There were, however, no significant changes in BP, and TG level after completing this program. This study suggests that Korean traditional dance exercise may be one of the effective nursing interventions for elderly women.

Enhanced Anti-reflective Effect of SiNx/SiOx/InSnO Multi-layers using Plasma Enhanced Chemical Vapor Deposition System with Hybrid Plasma Source

  • Choi, Min-Jun;Kwon, O Dae;Choi, Sang Dae;Baek, Ju-Yeoul;An, Kyoung-Joon;Chung, Kwun-Bum
    • Applied Science and Convergence Technology
    • /
    • v.25 no.4
    • /
    • pp.73-76
    • /
    • 2016
  • Multi-layer films of $SiN_x/SiO_x$/InSnO with anti-reflective effect were grown by new-concept plasma enhanced chemical vapor deposition system (PECVD) with hybrid plasma source (HPS). Anti-reflective effect of $SiN_x/SiO_x$/InSnO was investigated as a function of ratio of $SiN_x$ and $SiO_x$ thickness. Multi-layers deposited by PECVD with HPS represents the enhancement of anti-reflective effect with high transmittance, comparing to the layers by conventional radio frequency (RF) sputtering system. This change is strongly related to the optical and physical properties of each layer, such as refractive index, composition, film density, and surface roughness depending on the deposition system.

Theoretical and experimental study of robustness based design of single-layer grid structures

  • Wu, Hui;Zhang, Cheng;Gao, Bo-Qing;Ye, Jun
    • Structural Engineering and Mechanics
    • /
    • v.52 no.1
    • /
    • pp.19-33
    • /
    • 2014
  • Structural robustness refers to the ability of a structure to avoid disproportionate consequences to the original cause. Currently attentions focus on the concepts of structural robustness, and discussions on methods of robustness based structural design are rare. Firstly, taking basis in robust $H_{\infty}$ control theory, structural robustness is assessed by $H_{\infty}$ norm of the system transfer function. Then using the SIMP material model, robustness based design of grid structures is formulated as a continuum topology optimization problem, where the relative density of each element and structural robustness are considered as the design variable and the optimization objective respectively. Generalized elitist genetic algorithm is used to solve the optimization problem. As examples, robustness configurations of plane stress model and the rectangular hyperbolic shell model were obtained by robustness based structural design. Finally, two models of single-layer grid structures were designed by conventional and robustness based method respectively. Different interference scenarios were simulated by static and impact experiments, and robustness of the models were analyzed and compared. The results show that the $H_{\infty}$ structural robustness index can indicate whether the structural response is proportional to the original cause. Robustness based structural design improves structural robustness effectively, and it can provide a conceptual design in the initial stage of structural design.

Dielectric and Passivation-Related Properties of Pecvd PSG (PECVD PSG의 유전 및 보호막특성에 관한 연구)

  • 유현규;강영일
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 1985
  • The properties of plasma-enhanced CVD phosphorous silicate glass (PECVD PSG) for passivation layer are studied . Phosphorous contentration was analyzed with X-ray fluores-cence. As a result, PECVD PSG has a limiting phosphors concentration of about 8 mole%. Curves relating to etcll rate, infrared absorption ratio, and sheet resistivity were adapted to monitor phosphorous concentration indirectly Dielectric properties, step coverage, crack resistance, and gettering effect are discussed in both of atmospheric pressure CVD (APCVO) and PECVD oxide. PECVD SiO2 film have density of about 2.4 g/㎤ at deposition rate of 450$\AA$/min, refractive index of about 1.53, and breakdown at fields of II-13 MV/cm. Crack resistance of PECVD oxide is greater than APCVD oxide. PECVD PSG films contained with 2 mole % phosphorous show good step coverage and gettering ability. The obtained results show more advantages in PECVD PSG than in APCVD PSG for device passivation.

  • PDF

Sequential Stereoscopic Display System based on a Volume Holographic Memory (체적 홀로그래픽 메모리를 이용한 스테레오스코픽 동영상 디스플레이 시스템)

  • Lee, Seung-Hyeon;Seon, Gwang-Cheol;Kim, Eun-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.22-27
    • /
    • 2000
  • We present a sequential stereoscopic display system using volume holographic storage. Multiple angular multiplexed stereoscopic image pairs are recorded into a photorefractive crystal that can store data with high density, transfer them with high speed, and select a randomly chosen data element. The reference beam with Bragg selectivity is scattered by the index grating and the diffracted beams are propagating along the directions of the stereoscopic image pairs. The images are to be suitably projected on the left and right display plane sequentially for stereoscopic video viewing.

  • PDF

Effects of Treadmill Walking Exercise on BMD and BMI in Middle-Aged Women (트레드밀 걷기운동이 40대 중년여성의 골밀도 및 체질량지수에 미치는 영향)

  • Lee, Jung-In;Byeon, Young-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.15 no.1
    • /
    • pp.53-59
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of treadmill walking exercise on the BMD (Bone Mineral Density) and BMI (Body Mass Index) of middle-aged women in their forties. Method: A nonequivalent control group pretest-posttest design was used for this study. The experiment was conducted for 10 weeks from May 17 to July 25, 2004 with 29 middle-aged women in their forties, who were assigned to a walking exercise group (16) or a control group (13). The experimental group had not exercised regularly before participating in this program. The control group received no exercise treatment during the research period. The BMD and BMI were measured with peripheral dual energy x-ray absorptiometry and bioelectrical impidence analysis, respectively. $X^2-test$ and Mann-Whitney U test with the SPSS version 11.0 program were used to analyze the data. Result: Treadmill walking exercise was effective for middle-aged women in increasing BMD and decreasing BMI. Conclusion: The findings of this study indicate a need to develop walking exercise protocols for middle-aged women to help them achieve a healthy life.

  • PDF

Creatinine and microalbuminuria levels are increased in type 2 diabetic patients with hypertension (고혈압을 동반한 제2형 당뇨병 환자에서의 creatinine과 미세 단백뇨 증가)

  • Kim, Hee-Seung;Song, Min-Sun;Yoo, Yang-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.2
    • /
    • pp.51-58
    • /
    • 2002
  • The purpose of this study was to identify clinical characteristics of type 2 diabetic patients with hypertension. The subjects were 209 type 2 diabetic patients who visited at the endocrine center at Kangnam St. Mary's Hospital of Catholic University in Seoul from beginning of March through the end of April in 2001. The patient's clinical laboratory data were assessed at medical record review. The data were analyzed using for t-test, $x^2$ test. The results were as follows: 1) There were no significant differences in age, body mass index, sex, family history of diabetes and oral hypoglycemic agents between hypertensive group and normotensive group, However, percentage of patients receiving insulin treatment was higher significantly in the hypertensive group. 2) Creatinine and microalbuminuria levels were higher significantly in the hypertensive group. However, fasting blood glucose levels were lower significantly in the hypertensive group. There were no significant differences in $HbA_1c$, 2-hour postprandial blood glucose, total cholesterol, triglyceride, high density lipoprotein cholesterol, lipoprotein(a) and blood urea nitrogen between two groups. Our present study supports that Creatinine and microalbuminuria levels were higher significantly in the hypertensive group.

  • PDF

Study on Structure Design of High-Stiffness for 5 - Axis Machining Center (5축 공작기계의 고강성 구조설계에 관한 연구)

  • Hong, Jong-Pil;Gong, Byeong-Chae;Choi, Sung-Dae;Choi, Hyun-Jin;Lee, Dal-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.7-12
    • /
    • 2011
  • This study covers the optimum design of the 5-axis machine tool. In addition, the intelligent control secures structural stability through the optimum design of the structure of the 5-axis machine center, main spindle, and the tilting index table. The big requirement, like above, ultimately leads to speed-up operation. And this is inevitable to understand the vibration phenomenon and its related mechanical phenomenon in terms of productivity and its accuracy. In general, the productivity is correlated with the operation speed and it has become bigger by its vibration scale and the operation speed so far. Vibration phenomenon and its heat-transformation of the machine is naturally occurred during the operation. If these entire machinery phenomenons are interpreted through the constructive understanding and the interpretation of the naturally produced vibration and heat-transformation, it would be very useful to improve the rapidity and its stability of the machine operation indeed. In this dissertation, the problems of structure through heating, stability, dynamic aspect and safety about intelligent 5-wheel machine tool are discovered to examine. All these discoveries are applied to the structure in order to enhance the density of it. It aims to improve the stability.

Analyzing Friction Coefficient and Wettability of Micro-Dimple Fabricated Using Elliptical Vibration Texturing Method (이중 주파수 타원형 진동 궤적법 기반 마이크로 딤플의 마찰계수 및 습윤성 분석)

  • Park, Gun Chul;Ko, Tae Jo;Kurniawan, Rendi;Ali, Saood
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.38-44
    • /
    • 2020
  • Surface texturing of micro-dimples has been used in many manufacturing industries to reduce friction between two sliding contacted surfaces. Surface texturing decreases the frictional force owing to minimizing of the sliding contact area. In this paper, micro-dimples have been fabricated on an Al6061-T6 surface using a two-frequency elliptical vibration texturing (TFEVT) method. A high-frequency of 18 kHz and low-frequency of 250 Hz were applied to an elliptically-vibrated tool holder. The Stribeck curve was plotted to analyze the friction coefficient trends. Furthermore, the representative wetting index, such as the water contact angle (WCA), was measured by considering the friction coefficient. WCA is associated with micro-dimple density and associated parameters. Consequently, the dimpled surfaces with a low friction coefficient exhibited a relatively high WCA in the feed direction. According to the Stribeck curve, the dimpled surfaces demonstrate superior friction performance for mixed-film lubrication compared to the non-textured surface.

Improvement of MFL sensing-based damage detection and quantification for steel bar NDE

  • Kim, Ju-Won;Park, Minsu;Kim, Junkyeong;Park, Seunghee
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.239-247
    • /
    • 2018
  • A magnetic flux leakage (MFL) method was applied to detect and quantify defects in a steel bar. A multi-channel MFL sensor head was fabricated using Hall sensors and magnetization yokes with permanent magnets. The MFL sensor head scanned a damaged specimen with five levels of defects to measure the magnetic flux density. A series of signal processing procedures, including an enveloping process based on the Hilbert transform, was performed to clarify the flux leakage signal. The objective damage detection of the enveloped signals was then analyzed by comparing them to a threshold value. To quantitatively analyze the MFL signal according to the damage level, five kinds of damage indices based on the relationship between the enveloped MFL signal and the threshold value were applied. Using the proposed damage indices and the general damage index for the MFL method, the detected MFL signals were quantified and analyzed relative to the magnitude of the damage increase.