• 제목/요약/키워드: densitometer

검색결과 118건 처리시간 0.024초

DESIGN AND APPLICATION OF A SINGLE-BEAM GAMMA DENSITOMETER FOR VOID FRACTION MEASUREMENT IN A SMALL DIAMETER STAINLESS STEEL PIPE IN A CRITICAL FLOW CONDITION

  • Park, Hyun-Sik;Chung, Chang-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.349-358
    • /
    • 2007
  • A single-beam gamma densitometer is utilized to measure the average void fraction in a small diameter stainless steel pipe under critical flow conditions. A typical design of a single-beam gamma densitometer is composed of a sealed gammaray source, a collimator, a scintillation detector, and a data acquisition system that includes an amplifier and a single channel analyzer. It is operated in the count mode and can be calibrated with a test pipe and various types of phantoms made of polyethylene. A good average void fraction is obtained for a small diameter pipe with various flow regimes of the core, annular, stratified, and bubbly flows. Several factors influencing the performance of the gamma densitometer are examined, including the distance between the source and the detector, the measuring time, and the ambient temperature. The void fraction is measured during an adiabatic downward two-phase critical flow in a vertical pipe. The test pipe has an inner diameter of 10.9 mm and a thickness of 3.2 mm. The average void fraction was reasonably measured for a two-phase critical flow in the presence of nitrogen gas.

Comparison of Bone Mineral Density with Pencil Beam and Fan Beam DXA Machine

  • Park, Jeong-Hoon;Lee, Jae-Mun;Youn, Je-Woong;Suh, Tae-Suk;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.425-426
    • /
    • 2002
  • The bone densitometer is to investigate the bone mineral content and density for the osteoporosis assessment by using dual energy X-ray photons. For the clinical verification of the ISOL's OSTEO plus, the clinical study was performed with healthy and non-menopausal 30 female volunteers. The fan-beam DXA machine (Lunar, Expert) was chosen as a reference. After correlation analysis of their bone mineral densities, a strong correlation was obtained. From the results, it is claimed that the new forearm bone densitometer is clinically useful in osteoporosis diagnosis.

  • PDF

박층크로마토그라피 및 농도 측정법에 의한 Ampicillin Trihydrate 중의 N,N-Dimethylaniline의 검색 (Detection of N,N-Dimethylaniline in Ampicillin Trihydrate by Thin Layer Chromatography and Densitometry)

  • 이왕규;김박광;심창구
    • 약학회지
    • /
    • 제22권4호
    • /
    • pp.238-241
    • /
    • 1978
  • A simple and convenient method of detecting N, N-dimethy laniline (D.M.A.) residues in ampicillin trihydrate (A.T.) was established. D.M.A. was extracted by chloroform from the chloroform presaturated N/10-ammonia water solution of A.T. and chromatographed on silica gel G thin layer. Blue spot appeared in 15minutes after spray of 2, 6-dichloroquinonechlorimide solution was compared with the blue spot of reference concomitantly processed. The developing solvent was prepared by mixing equal volume of cyclohexane and chloroform. To quantitate the amount of D.M.A. in A.T., T.L.C. was performed with the Eastmann Chromatogram sheet, then color density was measured by Cosmo Superclick densitometer. The developing solvent at this time was cyclohexane-chlorofonn (3+7) mixture. The peak areas obtained with the amount of D.M.A ranging from 0.05 to 2.0 .mu.g were linear to color density. Better sensitive results would be available with the densitometer equipped with monochromator.

  • PDF

Uranium Solution Assay by L-edge Densitometer

  • Park, Seunghoon;Park, Uk-Ryang;Yoon, Jong-Ho;Kwak, Sung-Woo
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2016년도 추계학술논문요약집
    • /
    • pp.505-506
    • /
    • 2016
  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

LNG 밀도계를 이용한 저장 탱크 내 LNG 발열량 실시간 측정방법에 관한 연구 (A Study on the Method for Measuring the live Calorific Value of LNG in storage tank using LNG Densitometer)

  • 하영철;이성민
    • Korean Chemical Engineering Research
    • /
    • 제49권1호
    • /
    • pp.35-40
    • /
    • 2011
  • 가스호환성에 문제가 있는 저열량의 LNG가 도입되기 시작한 것은 2005년 동절기부터이다. 이러한 LNG의 도입량은 매년 증가하고 있으며 향후에는 극저열량(발열량 ${\leq}$ 9,500 kcal/$Nm^3$)의 CBM(Coal Bed Methane), Shale LNG도 대량 도입될 예정에 있다. 따라서 호환 가능한 발열량의 가스를 인수기지에서 송출하기 위해서는 저장 탱크별 LNG 발열량을 실시간으로 모니터링할 수 있는 방법이 필요하게 되었다. 본 연구에서는 이러한 방법의 일환으로 저장 탱크 내설치된 밀도계를 이용하여 LNG 발열량을 실시간으로 측정할 수 있는 방법을 개발하고자 하였다. 이를 위해 액상 LNG와 발열량 간의 정밀 정확한 상관식을 도출하고 이 방법의 불확도를 계산하였으며 또 인수기지 내 발열량 측정 시스템을 시험 구축하였다. 본 방법의 유효성을 확인하기 위해 현장 LNG 분석데이터와 비교하였으며 그 결과 0.17~0.47%정도의 편차를 확인하였다.

SOS를 이용한 초음파 골밀도 측정 장치 (Ultrasonic Bone Densitometer by Measuring the Speed of Sound)

  • 정민상;한은주;김영식
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.172-178
    • /
    • 2007
  • 가로축 방식이 아닌 세로축 방식으로 초음파를 송수신하여 골밀도 측정을 하는 장치를 개발하였다. 반사된 초음파의 시간 차이를 이용하는 speed of sound (SOS) 방식은 주파수 차이를 비교하는 broadband ultrasound attenuation (BUA) 방식에 비하여 더욱 정확한 결과를 얻을 수 있다. 측정부위의 경우 엄지는 초음파 수신율이 좋으나 피부 두께의 변위가 많은 단점을 고려하여 중지를 채택하여 정확성을 높였다. SOS 방식만을 사용하여 측정한 결과 기존의 dual-energy x-ray absorptiometry (DEXA) 방식과 비교하여 거의 동일한 정확도를 얻을 수 있었다.

  • PDF

펄스형 방전플라스마에서 발생하는 가시광선의 분광특성 연구 (Spectroscopy of Visible Light Emitted from Plasma Occurred by Pulse Discharge)

  • 최운상
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.27-31
    • /
    • 1998
  • 펄스형 방전플라즈마 발생장치인 플라스마 포커스장치에서 발생하는 가시광선영역의 빛을 시간분해분석법과 시간적분분석법으로 분광분석하였다. 플라스마포커스장치는 전극이 동축형으로 사용되었고, 시간 용해분석법은 고정된 파장의 광펄스를 오실로스코프로 분석하였으며, 시간 적분법을 일정한 범위의 파장대를 필림에 현상하여 densitometer로 분석하였다. 가시광선발생은 방전전압과 기체압력을 변수로 측정하여 방전전압은 17 kV이고 기체압력은 아르곤기체일 경우 0.5 torr가 최적조건이었다.

  • PDF

액체혼합물의 밀도 측정과 3차 상태방정식에 의한 과잉 몰부피의 예측 (Density Measurement of Liquid Mixture and Estimation of Excess Molar Volume by A Cubic Equation of State)

  • 김정민;배효광
    • Korean Chemical Engineering Research
    • /
    • 제43권5호
    • /
    • pp.637-640
    • /
    • 2005
  • 극성과 비극성의 물질인 methyl tert-butyl ether(MTBE)와 2,2,4-trimethylpentane 혼합물과 methyl ethyl ketone(MEK)와 2,2,4-trimethylpentane 2성분의 액체혼합물 그리고 극성의 물질인 MTBE과 MEK 2성분 액체혼합물의 밀도를 densitometer를 사용하여 278.15 K, 288.15 K, 298.15 K에서 각각 측정하였다. 측정한 밀도로부터 얻은 2성분계 과잉몰부피의 측정값과 Huron-Vidal의 혼합법칙을 사용한 Peng-Robinson-Stryjek-Vera(PRSV)의 3차 상태방정식으로부터 계산한 계산값이 잘 일치하였으며 극성물질을 포함한 혼합물의 몰부피 계산에 3차의 PRSV 상태방정식이 이용될 수 있음을 확인하였다.