• Title/Summary/Keyword: demand control

Search Result 2,320, Processing Time 0.028 seconds

MO Theoretical Studies on Diels-Alder Reactions of $\alpha$-Allenic Ketones$^*$

  • Han, Eun-Sook;Lee, Ik-choon;Chang Byung-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.5
    • /
    • pp.197-200
    • /
    • 1983
  • The Diels-Alder cycloaddition reactions between dienes and allenic ketones were studied theoretically using CNDO/2 method. It was found that the reaction is a neutral electron demand type with matrix element control and the reactivity, the regio- and stereo-selectivities can be correctly predicted based on interaction energies calculated with the 4-center FMO formalism.

A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method (부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석)

  • Kim, Dong Jun;Kang, Byung Ha;Chang, Young Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

A Study on Modeling of Watering Control status by Regions Using the Measurement Device of the Ministry of Root Environment (근권 환경부 측정장치를 이용한 지역별 관수제어 모델링 연구)

  • Jeong, Jin-Hyoung;Jo, Jae-Hyun;Kim, Seung-Hun;Choi, Ahnryul;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 2021
  • According to the World Agricultural Productivity Report, the current annual average growth rate of agriculture is 1.63%, which is lower than 1.73% to support the world's 10 billion people, which is growing by 2050. The demand for food, feed, and bioenergy is not growing enough to continue to meet the demand, and it is predicting a future food shortage. The purpose of this study was to create a regional irrigation control model for the purpose of reducing the production cost of crops, increasing production, and improving quality, and presenting a model that can give advice to farmers who start farming in the region. The irrigation control modeling presented in this study means to represent the change of medium weight·supply liquid·drainage amount due to changes in the root zone environment according to the passage of time and climate in a graph model. For water control modeling, we collected data on the change in the amount of the root zone environment and the weight of the badge·supply amount·drainage amount from March to June in Nonsan, Buyeo, and Yesan regions in Chungnam Province through the measuring device of the Ministry of Environment in the root region. We set up the parameters for derivation and derived an irrigation control model that can confirm the change in weight·supply liquid·drainage amount over time through the parameters.

Development of Interlocking Signal Simulator for Verification of Naval Warship Engineering Control Logics (함정 통합기관제어체계의 제어로직 검증을 위한 연동신호 시뮬레이터 개발)

  • Lee, Hunseok;Son, Nayoung;Shim, Jaesoon;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1103-1109
    • /
    • 2021
  • ECS is a control device so that the warship can perform the mission stably by controlling and monitoring the entire propulsion system. As the recent provisions of the warship, it's propelling system is complicated than past, as the demand performance and mission of the warships are diverse. In accordance with the complicated propulsion system configuration, the demand for automatic control function of the ECS is increasing for convenient and stable propulsion system control for convenient and stable. As a result, verification of ECS stability and reliability is required. In this paper, we develop an interlocking signal simulator for verifying ECS control logic and communication protocol for warship with CODLOG propulsion systems. The simulator developed was implemented to simulate a signal of gas turbine, propulsion motors, diesel generator and 11 kinds of auxiliary equipment. The reliability of ECS was verified through the ECS communication program and the I/O signal static test with the simulator.

The Development of Dynamic Model for Long-Term Simulation in Water Distribution Systems (상수관망시스템에서의 장기간 모의를 위한 동역학적 모형의 개발)

  • Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.4
    • /
    • pp.325-334
    • /
    • 2007
  • In this study, a long-term unsteady simulation model has been developed using rigid water column theory which is more accurate than Extended-period model and more efficient comparing with water-hammer simulation model. The developed model is applied to 24-hours unsteady simulation considering daily water-demand and water-hammer analysis caused by closing a valve. For the case of 24-hours daily simulation, the pressure of each node decreases as the water demand increase, and when the water demand decrease, the pressure increases. During the simulation, the amplitudes of flow and pressure variation are different in each node and the pattern of flow variation as well as water demand is quite different than that of KYPIPE2. Such discrepancy necessitates the development of unsteady flow analysis model in water distribution network system. When the model is applied to water-hammer analysis, the pressure and flow variation occurred simultaneously through the entire network system by neglecting the compressibility of water. Although water-hammer model shows the lag of travel time due to fluid elasticity, in the aspect of pressure and flow fluctuation, the trend of overall variation and quantity of the result are similar to that of water-hammer model. This model is expected for the analysis of gradual long-term unsteady flow variations providing computational accuracy and efficiency as well as identifying pollutant dispersion, pressure control, leakage reduction corresponding to flow-demand pattern, and management of long-term pipeline net work systems related with flowrate and pressure variation in pipeline network systems

Case Study on Revising Curriculum of a Industrial High School through Analysis of Manufacturing Workforce demand focused on Chungnam Province in Korea (지역 기반 산업의 인력 수요 분석을 통한 공업 계열 특성화 고등학교의 교육과정 개편 사례 연구)

  • Yi, Sangbong;Choi, Jiyeon
    • 대한공업교육학회지
    • /
    • v.38 no.1
    • /
    • pp.221-238
    • /
    • 2013
  • The purpose of this study was to revise and reorganize the direction of the department of ${\bigcirc}{\bigcirc}$Industrial High School though analysis of manufacturing status and workforce demand in Chungnam province focused on the Geumsan Area. In the study, ${\bigcirc}{\bigcirc}$Industrial High School of the status and actual conditions were identified through interview, literature review and data analysis. Surveys of the school teachers, parents and students was conducted in order to investigate the awareness of renaming and reorganization of school departments, curriculum revision of the school. Statistical data was collected and analyzed in order to figure out manufacturing industry and its workforce demand of Chungnam Province in Korea. Findings of the study were as follows: Small and medium enterprises of manufacturing industry have been developed a lot in Geumsan Area in Chungnam province. Four major industries including (1) automobile parts, (2) electronic and information equipment, (3) Cutting edge culture, and (4) Agricultural-livestock and bio are intensively fostered as regional strategic industries in the Chungnam province. The manufacturing industry has a 33.6-percent, and then service-mining and manufacturing industry has a 80.0-percent of total number of employee in Geumsan Area. It is expected that industrial workforce demand of Geumsan Area come out of manufacturing and service-mining industrial sector. The following is recommended for the school curriculum revision: (1) focussing on mechanical control for the revision of computer applying mechanical department, (2) focussing on automation electric equipment for the revision of electric control department, (3) focussing on food process control for revising of bio-food industrial department. It's helpful to make a progress of the school that establish identification of industrial specialized high school as an institution of vocational education at the secondary level through supplying qualified workforce to Manufacturing industry in Chungnam Province.

Economic Analysis of Optical Communication Control System in High Voltage Magnetizer (고전압 착자기에서의 누전 사고 방지를 위한 광통신 제어시스템의 도입 방안과 경제성 분석)

  • Bae, Young Woo;Kim, Wooju;Hong, June Seok
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.6
    • /
    • pp.103-117
    • /
    • 2019
  • Demand for high power motors is rapidly increasing as the 4th industry and convergence technology has recently emerged. In order to produce high-strength permanent magnets, the magnets used for magnetization have been increased from DC 300V in the 1970s to DC 2.5kV in the 2010s, Up to DC 10kV in the 2030s, It is expected that higher voltage will be used to magnetize. However, in the case of a magnetizer using an existing electric signal control device, it is necessary to use a control device with a high-voltage insulation function in case a high voltage used for magnetization is leaked to the control device. If a short circuit accident occurs, the controller must be shut down and serious problems such as excessive repair costs arise. In this study, a control system adopting optical communication method instead of electric signal control method is proposed to prevent leakage currents in high-voltage magnetizer. We design a transmitter(Tx) and a receiver(Rx) device for the optical communication control device and implemented a prototype connecting the optical cable. In order to demonstrate the utility of high-voltage magnetizer using the optical communication control device, we analyzed the initial cost and the yearly cost for the years to analyze the net present value. As a result, In the case of the low-voltage magnetizer, the electric signal control method cost less, As the operating voltage of the magnetizer becomes higher. It is confirmed that it takes less cost when the optical communication control device is used.

Coordinated Voltage Control Scheme for Multi-Terminal Low-Voltage DC Distribution System

  • Trinh, Phi Hai;Chung, Il-Yop;Kim, Taehoon;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1459-1473
    • /
    • 2018
  • This paper focuses on voltage control schemes for multi-terminal low-voltage direct current (LVDC) distribution systems. In a multi-terminal LVDC distribution system, there can be multiple AC/DC converters that connect the LVDC distribution system to the AC grids. This configuration can provide enhanced reliability, grid-supporting functionality, and higher efficiency. The main applications of multi-terminal LVDC distribution systems include flexible power exchange between multiple power grids and integration of distributed energy resources (DERs) using DC voltages such as photovoltaics (PVs) and battery energy storage systems (BESSs). In multi-terminal LVDC distribution systems, voltage regulation is one of the most important issues for maintaining the electric power balance between demand and supply and providing high power quality to end customers. This paper focuses on a voltage control method for multi-terminal LVDC distribution system that can efficiently coordinate multiple control units, such as AC/DC converters, PVs and BESSs. In this paper, a control hierarchy is defined for undervoltage (UV) and overvoltage (OV) problems in LVDC distribution systems based on the control priority between the control units. This paper also proposes methods to determine accurate control commands for AC/DC converters and DERs. By using the proposed method, we can effectively maintain the line voltages in multi-terminal LVDC distribution systems in the normal range. The performance of the proposed voltage control method is evaluated by case studies.

The Role of Charge and Retention in Effective Wet end Management

  • Rantala, T.;Nokelainen J.;Ojala, T;Dr. Taina Sopenlehto
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.1-10
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control sub-process through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are-white water consistency control which is the most effective way to control retention - charge demand measurement and control which takes care of concentration of the anionic material entering to PM -ash measurements and controls which are deeply related to retention and paper quality This paper presents and concentrates to two of these key controls ; retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloida material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately , and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation , and results of our unique wet end analyzers (retention and charge ) which are at the level of automation solutions as a part of paper machine quality control Especially our newest member of the platform , on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

The Role of Charge and Retention in Effective Wet End Management

  • Rantala, T.;Nokelainen, J.;Ojala, T.;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.44-53
    • /
    • 2000
  • The development of paper machines, increasing machine speeds with new, mostly low basis weight and/or high ash content paper grades, as well as the fact that several trends regarding process items have increased the sensitivity of papermaking. At the same time, papermakers are looking for flexibility in the production line. We can say that with all PMs, the biggest benefits with the lowest capital spending can be achieved by focusing on improved wet end management. In order to manage wet end chemistry on a paper machine, our goal is to control subprocesses through which we can influence the operation of the entire wet end with maximum effect. Key measurements and controls are - white water consistency control which is the most effective way to control retention. - charge demand measurement and control which takes care of concentration of the anionic material entering to PM. - ash measurements and controls which are deeply related to retention and paper quality. This paper presents and concentrates to two of these key controls: retention and charge. The purpose of charge control is to give the process control the tools to react to changes caused by amount of dissolved and colloidal material incoming to wet end system. It is called coagulation or fixing control. Retention control is then taking care of retention aid flow to the process by responding any changes seen in white water consistency. It is called flocculation control. Each of these solutions separately, and even more effectively all together, stabilize the wet end operations and so greatly improve the produced paper quality and machine runnability. Practical results will be presented and they are referring to the latest mill cases. We have developed the first wet end measuring system in the late 1980s and control solutions based on this modern measuring technology were completely updated in 1990s. This paper introduces the principle, operation, and results of our unique wet end analyzers (retention and charge) which are at the level of automation solutions as a part of paper machine quality control. Especially our newest member of the platform, on-line charge analyzer has reached and set new standards to the on-line charge monitoring.

  • PDF