• 제목/요약/키워드: delta-v

검색결과 1,146건 처리시간 0.025초

고속 DWA의 동작시간을 개선한 1.2V $3^{rd}$ 4bit 시그마 델타 변조기 설계 (The Design of 1.2V $3^{rd}$ Order 4bit Sigma Delta Modulator with Improved Operating Time of High Speed DWA)

  • 이순재;김선홍;조성익
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1081-1086
    • /
    • 2008
  • This paper presents the $3^{rd}$ 4bit sigma delta modulator with the block and timing diagrams of DWA(Data Weighted Averaging) to optimize a operating time. In the modulator, the proposed DWA structure has a stable operation and timing margin so as to remove three latches and another clock. Because the modulator with proposed DWA structure improve timing margin about 23%. It can increase sampling frequency up to 244MHz. Through the MATLAB modeling, the optimized coefficients are obtained to design the modulator. The fully differential SC integrators, DAC, switch, quantizer, and DWA are designed by considering the nonideal characteristics. The designed $3^{rd}$ order 4bit modulator has a power consumption of 40mW and SNR(signal to noise ratio) of 77.2dB under 1.2V supply and 64MHz sampling frequency.

Zn-Pr-Co-Cr-Tb계 바리스터의 전기적 특성 및 안정성에 소결온도가 미치는 영향 (Effect of Sintering Temperature on Electrical Properties and Stability of Zn-Pr-Co-Cr-Tb-Based Varistors)

  • 남춘우
    • 한국재료학회지
    • /
    • 제17권6호
    • /
    • pp.298-302
    • /
    • 2007
  • The electrical properties and its stability of Zn-Pr-Co-Cr-Tb-based varistors were investigated for different sintering temperatures. As the sintering temperatures increased, the varistor voltage decreased in the range of $705.2{\sim}299.1$ V/mm, the nonlinear coefficient decreased in the range of $42.4{\sim}31.7$, and the leakage current was in the range of $1.0{\sim}1.7\;{\mu}A$. The stability of electrical characteristics increased with the increase of sintering temperature. The varistors sintered at $1350^{\circ}C$ marked the high electrical stability, with $%\Delta$ $V_{1mA}=+0.1%,\;%\Delta{\alpha}=+3.2%$, and $%{\Delta}I_L=+117.6%$ for DC accelerated aging stress state of $0.95V_{1mA}/150^{\circ}C/24\;h$.

구리 산화물 계열 초전도체에서의 스핀 요동에 의한 자체 에너지의 엘리아시버그 계산 (Eliashberg Calculation of the Momentum-Resolved Self-Energy for the Cuprate Superconductors Induced by the Spin Fluctuations)

  • 홍승환;최한용
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.146-150
    • /
    • 2012
  • We solve the momentum resolved d-wave Eliashberg equation employing the magnetic excitation spectrum from the inelastic neutron scattering on the LSCO superconductors reported by Vignolle et al. The magnetic excitation spectrum exhibits 2 peaks: a sharp incommensurate peak at 18 meV at momentum (${\pi}$, ${\pi}{\pm}{\delta}$) and (${\pi}{\pm}{\delta}$, ${\pi}$) and another broad peak near 40~70 meV at momentum (${\pi}$, ${\pi}$). Above 70 meV, the magnetic excitation spectrum has a long tail that is shaped into a circle centered at (${\pi}$, ${\pi}$) with ${\delta}$. The sign of the real part of the self-energy is determined by the momentum position of the peaks of the magnetic excitation spectrum and bare dispersion. We will discuss the effects of the each component of the magnetic excitation spectrum on the self-energy, the pairing self-energy.

345kV 변압기 3차 모선결선을 통한 보호용 변류기 결선의 이해 (Understanding CT Connection through 3rd Bus Connection of the 345kV Auto Transformer)

  • 윤중덕;김재열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.439-440
    • /
    • 2015
  • 한전의 전력계통망에 사용중인 345kV 변압기는 1차와 2차 권선의 일부회로를 공통으로 사용하는 단상 단권변압기를 사용하고 있다. 단상변압기로 인한 3차결선은 변압기 외부에서 알루미늄 부스바를 이용하여 모선을 구성한다. 한편, ${\Delta}$결선의 특징은 3차측 붓싱의 극성과 관련하여 결선방식에따라 3차측 위상이 1차측 위상보다 $30^{\circ}$진상 또는 지상의 위상특성을 가지고 있어 비율차동계전기 결선방식에 있어 주의를 요한다. 변압기는 YNautod1결선 또는 YNautod11으로 결선할 수 있다. 한편 비율차동기용 결선은 1차측과 2차측은 ${\Delta}$결선으로 3차측은 Y결선으로 비율차동계전기에 입력이 되어야 한다. 이때 3차측의 위상을 고려하여 1차측과 2차측의 CT ${\Delta}$결선은 변압기 결선방식과 동일한 결선으로 시행하여 한다.

  • PDF

A reducible case of double hypergeometric series involving the riemann $zeta$-function

  • Park, Junesang;H. M. Srivastava
    • 대한수학회보
    • /
    • 제33권1호
    • /
    • pp.107-110
    • /
    • 1996
  • Usng the Pochhammer symbol $(\lambda)_n$ given by $$ (1.1) (\lambda)_n = {1, if n = 0 {\lambda(\lambda + 1) \cdots (\lambda + n - 1), if n \in N = {1, 2, 3, \ldots}, $$ we define a general double hypergeometric series by [3, pp.27] $$ (1.2) F_{q:s;\upsilon}^{p:r;u} [\alpha_1, \ldots, \alpha_p : \gamma_1, \ldots, \gamma_r; \lambda_1, \ldots, \lambda_u;_{x,y}][\beta_1, \ldots, \beta_q : \delta_1, \ldots, \delta_s; \mu_1, \ldots, \mu_v; ] = \sum_{l,m = 0}^{\infty} \frac {\prod_{j=1}^{q} (\beta_j)_{l+m} \prod_{j=1}^{s} (\delta_j)_l \prod_{j=1}^{v} (\mu_j)_m)}{\prod_{j=1}^{p} (\alpha_j)_{l+m} \prod_{j=1}^{r} (\gamma_j)_l \prod_{j=1}^{u} (\lambda_j)_m} \frac{l!}{x^l} \frac{m!}{y^m} $$ provided that the double series converges.

  • PDF

ZPCCL계 세라믹스의 바리스터 특성 (Varistor Properties of ZPCCL-based Ceramics)

  • 남춘우
    • 한국재료학회지
    • /
    • 제16권7호
    • /
    • pp.416-421
    • /
    • 2006
  • The varistor properties of ZPCCL-based ceramics were investigated at different $La_2O_3$ contents in the range of $0{\sim}2.0$ mol%. As $La_2O_3$ content increased, the ceramic density greatly increased in the range of $4.71{\sim}5.77\;g/cm^3$ and the varistor voltage greatly decreased in the range of $503.5{\sim}9.4$ V. The varistor with 0.5 mol% $La_2O_3$ exhibited good nonlinearity, in which the nonlinear exponent is 81.6 and the leakage current is 0.2 ${\mu}A$. Furthermore, the varistors exhibited the high electrical stability, with $%{\Delta}V_{1mA}=-1.1%,%{\Delta}{\alpha}=-3.7%$, and $%{\Delta}I_L=+100%$ for DC accelerated aging stress condition of 0.95 $V_{1mA}/150^{\circ}C/24$ h.

반주기 슬라이딩 윈도우와 재귀적 실효치 계산을 이용한 국내 플리커 평가지수 산출기법 (Equivalent 10-Hz Flicker Index Calculation Using Half-cycle Sliding Window and Recursive RMS Method)

  • 조수환
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2017-2020
    • /
    • 2011
  • Flicker, which is also known as voltage fluctuation, is an electromagnetic phenomenon generated by large scale nonlinear loads, such as arc furnaces and welding machines. Since a severe and continuous flicker can cause to some damages to electrically sensitive loads as well as human's visual irritations, it needs to be appropriately managed by being accurately measured, quantified and assessed. In Korea, an equivalent 10-Hz flicker index, shortly ${\Delta}V10$, is used to determine the permission limit of flicker. This paper presents an efficient calculation of the flicker index by using a half-cycle sliding window and a recursive method, showing a concrete calculating procedure of ${\Delta}V10$ from the viewpoint of signal processing.

[Cu(dl-trans-[14]-diene)]$^{2+}$ 착이온과 음이온 (S$_2O_3^{2-},\;SCN^-,\;I^-$ 및 NO$_2^-$)간의 화학반응에 대한 열역학적 성질 (${\Delta}G;\;{\Delta}H;\;{\Delta}V$) (Thermodynamic Properties for the Chemical Reactions of [Cu(dl-trans-[14]-diene)]$^{2+}$ with S$_2O_3^{2-},\;SCN^-,\;I^-\;and\;NO_2^-$)

  • 박유철;변종철
    • 대한화학회지
    • /
    • 제29권3호
    • /
    • pp.239-246
    • /
    • 1985
  • [Cu(dl-trans-[14]-diene)]$^{2+}$ 착이온과 음이온(L$^{n-}$ = S$_2$O$_3^{2-}$, SCN$^-$, I$^-$, NO$_2^-$)사이의 화학평형 관계를 온도 15 ~ 35$^{\circ}C$, 압력 1 ~ 1500bar 범위에서 분광광도법으로 연구하였다. S$_2$O$_3^{2-}$, SCN$^-$, I$^-$ 및 NO$_2^-$일때 평형상수 K는 25$^{\circ}C$, 1500bar에서 각각 3.0, 1.9, 0.6 및 0.5이었다. K값은 온도와 압력이 증가함에 따라 감소하였다. K에 대한 온도 영향으로 부터 열역학적 파라메터(${\Delta}G^{\circ}$, ${\Delta}H^{\circ}$, ${\Delta}S^{\circ}$)를 계산하였으며, 이 결과 NO$_2^-$이온을 제외한 다른 이온(S$_2$O$_3^{2-}$, SCN$^-$, I$^-$)에서는 모두 발열반응으로 나타났다. K에 대한 압력 영향에서 얻은 반응체적변화(${\Delta}$V)는 각 음이온에서 모두 양의 값이었다. S$_2$O$_3^{2-}$ 이온일 때 1,500, 1,000 및 1,500bar에서의 ${\Delta}$V(cm$^3$/mole)는 각각 26,22,19 및 16이었고, 상압에서 S$_2$O$_3^{2-}$, SCN$^-$, I$^-$ 및 NO$_2^-$이온일 때 ${\Delta}$V(cm$^3$/mole)는 각각 26, 30, 64 및 45이었다. S$_2$O$_3^{2-}$이온인 경우 Fuoss식에 의하여 계산한 평형상수와 실험치를 비교하여 Cu(Ⅱ) 착이온과 L$^{n-}$간의 결합성을 고찰하였다.

  • PDF

미세 열에너지 하비스팅용 열전박막소자의 형성공정 및 발전특성 (Fabrication Process and Power Generation Characteristics of Thermoelectric Thin Film Devices for Micro Energy Harvesting)

  • 오태성
    • 마이크로전자및패키징학회지
    • /
    • 제25권3호
    • /
    • pp.67-74
    • /
    • 2018
  • 두께 $2.5{\sim}10{\mu}m$인 n형 $Bi_2Te_3$와 p형 $Sb_2Te_3$ 레그 8쌍으로 구성되어 있는 in-plane형 열전박막소자를 전기도금법으로 Si submounts에 형성하고, LED 칩의 구동에 의해 발생하는 겉보기 온도차 ${\Delta}T$와 레그 두께에 따른 발전특성을 분석하였다. LED 방출열에 의해 인가된 ${\Delta}T$가 7.4K일 때 각기 두께 $2.5{\mu}m$, $5{\mu}m$$10{\mu}m$의 p-n 레그들로 구성된 열전박막소자는 6.1 mV, 7.4 mV 및 11.8 mV의 open circuit 전압을 나타내었으며, 6.6 nW, 12.8 nW 및 41.9 nW의 최대 출력전력을 나타내었다.

Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator

  • Kim, Hee-Dong;Kong, Tae-Sik;Kim, Kyeong-Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.421-424
    • /
    • 2016
  • In order to evaluate the insulation deterioration in the stator windings of air-cooled gas turbine generators(119.2 MVA, 13.8 kV) which has been operating for more than 15 years, diagnostic test and AC dielectric breakdown test were performed on phases A, B and C. Diagnostic test included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B, and C) of generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable condition. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. Although phase A of generator stator windings failed at breakdown voltage of 29.0 kV, phases B and C endured the 29.0 kV. The breakdown voltage in all three phases was higher than that expected for good-quality windings (28.6 kV) in a 13.8 kV class generator.