• Title/Summary/Keyword: degree of contamination

Search Result 338, Processing Time 0.023 seconds

A Study on the Influence of Al Alloy Sacrificial Anode Efficiency due to Marine Environmental Variation (해양환경 변화가 알루미늄합금 희생양극의 효율에 미치는 영향에 관한 연구)

  • 김도형
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.106-111
    • /
    • 2000
  • Recently it was reported that the life of Al Sacrifical anode is being used in port piers has been significantly shortened compared with the original design life (e.g. average life shortened from 20 years to 13-15 year) Those factors involving these problems mentioned above were seemed to be a quality of anode material and diverse environmental factors such as pH flow rate temperature Dissolved oxygen Chemical oxygen demand and resistivity etcm In this study flow rate and contamination degree(pH) of sea water affecting to sacrificial anode life hve been investigated in terms of electrochemical characteristics of Al alloy sacrificial anode It was known that the lifetime of Al alloy anode was shortened not only by increasing of self-corrosion quantity by varying flow rate of sea water but also by increasing corrosion current density due to the potential difference increment between Al anode and steel structure cathode by varying contamination degree of sea water. Especially when anode current density is from 1mA/cm2 to 3mA/cm2 and flow rate of sea water is under 2m/s anode current efficiency is 90% above However flow rate is over 2m/s anode current efficiency fell down sharply due to erosion corrosion as well as galvanic corrosion.

  • PDF

A Prediction on the Salt Contamination Degree with Statistical Analysis (통계 처리 기법을 활용한 염해 오손도 예측)

  • Choi, N.H.;Han, S.O.;Park, K.S.;Koo, K.W.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1903-1905
    • /
    • 2002
  • The degree of contamination on outdoor insulator is one of the most important factors for the determination of insulation level. And the salt, NaCl, is known as the most dangerous contaminants in the most region of the world. As shown through the preceding study, we could find the close relationship between the generation and deposition of salt contaminants and the meteorological conditions. To analyze the relationship, we monthly measured the ESDD for some sites with brush wiping method, and daily measured the density for one site with the automatic measuring apparatus. And, with the measured data and the meteorological data from KMA(Korea Meteorological Administration), we analyzed the relationship between the two factors with regression method. Through the results of this investigation, we could quantify the comparative contribution of the climatic factors for the pollution level of outdoor insulator, and the results could be used as a useful reference for the maintenance of overhead lines and substations.

  • PDF

A STUDY ON THE EFFECT OF MOISTURE ON APICAL SEALING PROPERTY OF ROOT CANAL (근관충전 시 수분오염이 치근단 폐쇄성에 미치는 영향에 관한 연구)

  • Lim, Sung-Sam;Kang, Myung-Whai
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.628-634
    • /
    • 1996
  • The purpose of this study was to investigate the effect of moisture on apical sealing properties of root canal. Fifty five single rooted human teeth were selected from maxillary and mandibular teeth. After removing crown portion at the cemento-enamel junction, all teeth were routinely prepared with step-back method. And then, the canals were dried with paper point and the teeth were randomly divided into 3 groups of 15 teeth each, and remaining 10 teeth were used as positive and negative control teeth : Group 1 were irrigated with 1ml of 95% alcohol and dried with air and paper point. Group 2 and 3 were intentionally contaminated with 0.05ml of 3.5% NaOCl or saliva, respectively. All the teeth were obturated with sealapex and gutta percha cone by lateral condensation technique, and covered with two coat of nail varnish after 48 hours of obturation. The teeth were immersed in india ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows : 1. All experimental groups showed varying degrees of dye penetration, and the mean degree of dye penetration was 0.1mm to 0.7mm. 2. Saliva contamination group(group 3) showed the highest amount of dye penetration, followed by NaOCl contamination group, then alcohol dried group, but there was no significant difference among three experimental groups. * This results suggest that there was no significant differences of apical leakage after canal obturation between alcohol dried canal and moisture present canals and the use of alcohol instead of paper point is unnecessary to dry the canals prior to canal filling. But other factors such as bacterial contamination and sealer discoloration by moisture must be considered in application of this results to clinical practice.

  • PDF

Cadmium, Cu, Ph and Zn Contamination of Stream Sediments and Waters in a Stream Around the Dalsung Cu-W Mine, Korea (달성 Cu-W 광산 주변 수계의 하상퇴적물과 자연수의 Cd, Cu, Pb 및 Zn 오염)

  • Jung, Myung Chae
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 1996
  • In order to investigate the extent and degree of Cd, Cu, Pb and Zn contamination affected by mining activities of the Dalsung Cu~W mine, sampling of stream sediments and waters has been undertaken up to 1.5 km downstream from the mine at 50~150 meter intervals. Analysis of the samples was carried out using ICP-AES for Cd, Cu, Pb and Zn. Physical and chemical properties of sediments (pH, organic matter contents, cation exchange capacity) and waters (pH, Eh and temperature) were also measured. The properties of the sediment samples were characterized by low pH (3.0~5.5), low organic matter contents (2~5%) and a moderate degree of cation exchange capacity (7~15 meq/100 g) with a high proportion of sand fraction. The pH values of water samples ranged from 3.0 to 5.0 and the Eh levels were in the range of 350~530 mV. Concentrations of Cd, Cu, Pb and Zn in the sediments averaged 3.2 mg/kg, 1,390 mg/kg, 451 mg/kg and 262 mg/kg with the range of 0.6~11.4 mg/kg, 15~3,800 mg/kg, 14~1,330 mg/kg and 63~1,060 mg/kg, respectively. Significant levels of the heavy metals were also found in the water samples with the range of $10{\sim}170{\mu}gCd/l$, $300{\sim}41,600{\mu}gCu/l$, $10{\sim}80{\mu}gPb/l$ and $700{\sim}15,400{\mu}gZn/l$. These elevated concentrations in the sediments and waters may be caused by the weathering of mine waste materials and their high solubilities under acidic and/or oxidizing conditions. Although metal concentrations in the samples decrease with the distance from the mine, heavy metal contamination of sediments and waters were also found at the 1.5 km downstream due to the mobile conditions of the heavy metals, with particular reference to Cd and Zn in stream waters.

  • PDF

Heavy metal assessment of marine sediment in selected coastal districts of the Western Region, Ghana

  • Kuranchie-Mensah, Harriet;Osei, Juliet;Atiemo, Sampson M.;Nyarko, Benjamin J.B.;Osae, Shiloh K.;Laar, Cynthia;Ackah, Michael;Buah-Kwofie, Archibold;Blankson-Arthur, Sara;Adeti, Prince J.
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.155-166
    • /
    • 2013
  • A preliminary investigation to establish the status of contamination of trace metals in the Western coast of Ghana was conducted prior to the commercial production of crude oil in the area. The study revealed the presence of heavy metals such as Pb (4.00-79.64 mg/kg), As (8.81-236 mg/kg), Cu (12.86-108.06 mg/kg), V (28.07-953.32 mg/kg), Zn (7.08-264.25 mg/kg), Cr (101.69-1366.62 mg/kg), Ni (42.41-451.43 mg/kg), Mn (16.77-1890.45mg/kg), Br (7.66-142.78 mg/kg), Ti (542.03-19960 mg/kg) and Fe (7472.88-97120 mg/kg) at six sites sampled along the coast. With the exception of Ti and Fe which showed no variation in metal concentration, the rest of the metals varied significantly among the sampled locations. Potential ecological risk of metals particularly of Co, As and Br which exhibited extreme enrichment of the sediments indicates considerable metal pollution in the studied areas. The degree of contamination is of particular concern especially to benthic biota that inhabit this environment for survival.

Interference Management by Vertical Beam Control Combined with Coordinated Pilot Assignment and Power Allocation in 3D Massive MIMO Systems

  • Zhang, Guomei;Wang, Bing;Li, Guobing;Xiang, Fei;lv, Gangming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.2797-2820
    • /
    • 2015
  • In order to accommodate huge number of antennas in a limited antenna size, a large scale antenna array is expected to have a three dimensional (3D) array structure. By using the Active Antenna Systems (AAS), the weights of the antenna elements arranged vertically could be configured adaptively. Then, a degree of freedom (DOF) in the vertical plane is provided for system design. So the three-dimension MIMO (3D MIMO) could be realized to solve the actual implementation problem of the massive MIMO. However, in 3D massive MIMO systems, the pilot contamination problem studied in 2D massive MIMO systems and the inter-cell interference as well as inter-vertical sector interference in 3D MIMO systems with vertical sectorization exist simultaneously, when the number of antenna is not large enough. This paper investigates the interference management towards the above challenges in 3D massive MIMO systems. Here, vertical sectorization based on vertical beamforming is included in the concerned systems. Firstly, a cooperative joint vertical beams adjustment and pilot assignment scheme is developed to improve the channel estimation precision of the uplink with pilots being reused across the vertical sectors. Secondly, a downlink interference coordination scheme by jointly controlling weight vectors and power of vertical beams is proposed, where the estimated channel state information is used in the optimization modelling, and the performance loss induced by pilot contamination could be compensated in some degree. Simulation results show that the proposed joint optimization algorithm with controllable vertical beams' weight vectors outperforms the method combining downtilts adjustment and power allocation.

A Study on the Environmental Professionals′ Risk Perception towards Some Pollution Issues (일부 환경 전문가들의 환경 위해성 인식도에 관한 연구)

  • 신동천;박종연;임영욱;김진용;장은아;박성은
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.4
    • /
    • pp.175-187
    • /
    • 1999
  • To investigate the risk perception of environmental issues, two consequtive surveys were conducted to environmental professionals using a standardized questionnaire from September to October in 1999. The number of subjects were 72 for the first survey and 68 for the second one. The questionnaire was consisted of items such as the degree of environmental pollution in Korea, risk perception of some issues on human health and ecosystem, and seriousness of the problems in the real situation in Korea. For the degree of environmental pollution in Korea, the average risk rating in the second test (7.4 point) was significantly higher than that in the first test (7.2 point). The risk perception on the general human health and ecosystem, and the seriousness in Korea situation were analyzed in the order of ′air pollution′, ′water pollution′,′soil contamination′,′waste′,′toxic chemical pollutants′,′food contamination′,′ocean contamination′, ′odor pollution′, and ′noise pollution′. Also ′toxic chemical pollutants′ problem was perceived to be the highest risk on general human health or ecosystem, and on present situation in Korea. ′Automotive vehicle exhaust′ problem was perceived to be the most severe environmental problems among specific 30 items. ′Industrial source air pollution′,′toxic air pollutants′, and ′domestic and industrial source pollutants to surface water′ were relatively severe environmental problems comparing to other problems. The pollution issues were classified into four categories by two aspects of perception; risk in general setting and seriousness in Korea situation. If the issues were highly serious in Korea and low risk perception in general setting then it is named "the Korea-specific group". Those that were all high score in two aspects, named "the Common group". Those that were all low in two aspects, named "the Nonsignificant group". And the issues were high risk perception in general setting and low seriousness in Korean situation, named "the Latent group".

  • PDF

Microbial Contamination according to the Numbers of Mask Worn in the Community

  • Eun Ju Lee;Heechul Park;Min-A Je;Songhee Jung;Gahee Myoung;Su Bin Jo;Hyun Min Hwang;Ryeong Si;Hyunwoo Jin;Kyung-Eun Lee;Jungho Kim
    • Biomedical Science Letters
    • /
    • v.28 no.4
    • /
    • pp.317-321
    • /
    • 2022
  • Due to COVID-19 pandemic, wearing face masks is obligatory to prevent respiratory virus transmissions in the community. However, there are few studies of the desirable number of wearing a face mask, and how to store them for reuse. Therefore, in this study, a survey was conducted among 208 healthy adults, and 27 kf-94 masks worn for 1, 2, and 3 days were collected. To estimate the risk of bacterial contamination, we analyzed the extent of bacterial contamination of the BHI medium and 16S rRNA gene sequencing. With an increase in the number of days of using the mask, the degree of bacterial contamination of the used mask gradually increased. As a result of 16S rRNA PCR performed for strain identification, Staphylococcus, known as a pathogenic bacterium, was identified the most. In conclusion, we found that wearing a cotton KF mask provides an optimal environment for microbes, which are related to the skin and respiratory system, to thrive. Therefore, it is also important to reduce the risk of bacterial infection of the face mask with appropriate sterilization methods.

CHARACTERIZATION OF METALLIC CONTAMINATION OF SILICON WAFER SURFACES FOR 1G DRAM USING SYNCHROTRON ACCELERATOR

  • Kim, Heung-Rak;Kun-Kul, Ryoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.239-243
    • /
    • 1999
  • At Present, 200mm wafer technology is being applied for commercial fabrications of 64, 128, and 256 M DRAM devices, and 300mm technology will be evolved for 1G DRAM devices in the early 21th century, recognizing limitations of several process technologies. In particular recognition has been realized in harmful effects of surface contamination of trace metals introduced during devicing processes. Such a guide line for surface metal contamination has been proposed as 1E9 and 1E10 atoms/$\textrm{cm}^2$ of individual metal contamination for wafering and devicing of 1G DRAM, respectively, and so its measurement limit should be at least 1E8 atoms/$\textrm{cm}^2$. The detection limit of present measurement systems is 2E9 atoms/$\textrm{cm}^2$ obtainable with TRXFA(Total Reflection X-Ray Fluorescence Analysis). TRXFA is nondestructive and the simplest in terms of operation, and it maps the whole wafer surfaces but needs detection improvement. X-Ray intensity produced with synchrotron accelerator is much higher than that of conventional X-ray sources by order of 4-5 magnitudes. Hence theoretically its reactivity with silicon surfaces is expected to be much higher than the conventional one, realizing improvement of detection limit. X-ray produced with synchrotron accelerator is illuminated at a very low angle with silicon wafer surfaces such as 0.1 degree and reflects totally. Hence informations only from surface can be collected and utilized without overlapping with bulk informations. This study shows the total reflection phenomenon and quantitative improvement of detection limit for metallic contamination. It is confirmed that synchrotron X-ray can be a very promising alternative for realizing improvement of detection limit for the next generation devices.

  • PDF

Microbial Contamination of Reusable Suction Container and Cost Analysis of Reusable Suction Container and Disposable Suction Container (재사용 흡인 용기의 미생물 오염도 및 재사용 흡인 용기와 일회용 흡인 용기의 비용 분석)

  • Ku, Eunyong;Lee, Gukgeun;Jeon, Miyang;Choi, Jeonghwa;Lee, Youngok
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.2
    • /
    • pp.133-140
    • /
    • 2019
  • Purpose: The purpose of this study was to check the degree of residual microbial contamination after disinfection of reusable suction containers, used in an intensive care unit (ICU) and present basic data for efficient use through cost analysis in comparison to disposable suction containers. Methods: This study was conducted on 32 reusable suction containers used in an ICU on a selected specific day. After disinfection and washing, specimens were collected from the used containers and cultured to check for microbial contamination. Additionally, a comparative narrative study analyzes the cost of using reusable suction containers and disposable suction containers. Data were analyzed with the SPSS WIN 20.0 program using real numbers and percentage ${\chi}^2$-test. Results: As a result of the study, microorganisms were found in all samples where in 30 were gram-positive (62.5%) while 13 were gram-negative (27.1%). Based on level of contamination, microorganisms were less than 10CFU/ml in 18 samples (56.3%); 11-99CFU/ml in six samples (18.8%); and more than 100CFU/ml in eight samples (25%). Cost per day for a reusable suction container was $10,655+{\alpha}$ while cost per day for a disposable suction container was 10,666 won. Conclusion: This study found that reusable suction containers, even after disinfection, accounted for factors of potential infection as well as microbial contamination. So, disposable suction containers are superior in cost-effectiveness and highly efficient for use with infected patients.