• Title/Summary/Keyword: degradation test

Search Result 1,845, Processing Time 0.034 seconds

Microstructures and Electrochemical Properties of Si-M (M : Cr, Ni) as Alloy Anode for Li Secondary Batteries (리튬이차전지용 Si-M (M : Cr, Ni) 합금 음극의 미세구조와 전기화학적 특성)

  • Lee, Sung-Hyun;Sung, Jewook;Kim, Sung-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • To compare the microstructure and electrochemical properties between two binary alloys (Cr-Si, Ni-Si), two composition of binary alloys with the same capacity were selected using phase-diagram and prepared by matrix-stabilization method to suppress the volume expansion of Si by inactive-matrix. Master alloys were made by Arc-melting followed by fine structured ribbon sample preparation by Rapid Solidification Process (RSP, Melt-spinning method) under the same conditions. Also powder samples were produced by wet grinding for X-Ray Diffraction (XRD) and electrochemical measurements. As predicted from the phase diagram, only active-Si and inactive-matrix ($CrSi_2$, $NiSi_2$) were detected. The results of Scanning Electron Microscope (SEM) and Transmission Electron Microscopy - Energy Dispersive X-ray Spectroscopy (TEM-EDS) show that Cr-Si alloy has finer microstructure than Ni-Si alloy, which was also predictable through phase diagram. The electrochemical properties related to microstructure were evaluated by coin type full- and half-cells. Separately, self-designed test-cells were used to measure the volume expansion of Si during reaction. Volume expansion of Cr-Si alloy electrode with finer microstructure was suppressed significantly and improved in cycle capability, in comparison Ni-Si alloy with coarse microstructure. From these, we could infer the correlation of microstructure, volume expansion and electrochemical degradation and these properties might be predicted by phase diagram.

Ability to Resist Chloride Ion Penetration and Dry Shrinkage Evaluation of Magnesium Phosphate Ceramics (인산마그네슘 세라믹의 염소 이온 투과 저항성 및 길이변화 특성에 관한 성능 평가)

  • Ko, Jeong-Won;Yang, Wan-Hee;Park, Dong-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.341-348
    • /
    • 2017
  • The performance degradation of concrete pavement by winter deicer is very serious in Korea, and its maintenance and rehabilitation brings a high expense. Therefore, a suitable method for rehabilitation of such concrete pavement and repair material of proper performance are required. In this study, the properties of compressive strength, ability to resist chloride ion penetration, and properties of dry shrinkage of magnesium phosphate ceramics were assessed to evaluate its applicability as a repair material for concrete pavement in Korea. As a result, the mortar flow showed a normal level of 190 mm, but the viscosity was high and the self-flow ability was poor. The setting time was 12 minutes, leading very rapid-hardening, and thus a prompt work was required. The compressive strength of mortar was 38.4MPa in 2 hours, 73.8MPa in 24 hours, and 111.0MPa in 28 days, showing a significant level. As a result of the test to chloride ion penetration resistance, mortar showed 143 Coulombs, and concrete showed 172.6 Coulombs, which fell under very low level. The drying shrinkage of MPC concrete in 40 days was below $60{\times}10-6$, and comparing with normal cement concrete, it showed the level below 1/10 of other concrete to secure an excellent volume stability. As above, magnesium phosphate ceramics has excellent strength performance, chloride ion penetration resistance, and volume stability, and this in the future shall be used in construction under the consideration of working time or workability, requiring further improvement for such performance.

Remaining Useful Life Prediction of Li-Ion Battery Based on Charge Voltage Characteristics (충전 전압 특성을 이용한 리튬 이온 배터리의 잔존 수명 예측)

  • Sim, Seong Heum;Gang, Jin Hyuk;An, Dawn;Kim, Sun Il;Kim, Jin Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.313-322
    • /
    • 2013
  • Batteries, which are being used as energy sources in various applications, tend to degrade, and their capacity declines with repeated charging and discharging cycles. A battery is considered to fail when it reaches 80% of its initial capacity. To predict this, prognosis techniques are attracting attention in recent years in the battery community. In this study, a method is proposed for estimating the battery health and predicting its remaining useful life (RUL) based on the slope of the charge voltage curve. During this process, a Bayesian framework is employed to manage various uncertainties, and a Particle Filter (PF) algorithm is applied to estimate the degradation of the model parameters and to predict the RUL in the form of a probability distribution. Two sets of test data-one from the NASA Ames Research Center and another from our own experiment-for an Li-ion battery are used for illustrating this technique. As a result of the study, it is concluded that the slope can be a good indicator of the battery health and PF is a useful tool for the reliable prediction of RUL.

A Study on the Biodegradability of Some Pesticides in Water (물 중에서 일부 농약의 생분해성에 환한 연구)

  • 민경진;차춘근
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.2
    • /
    • pp.125-132
    • /
    • 2001
  • The present study was conducted to investigate biological degradability of phosphamidon and profenfos. In the biodegradation test of two pesticides by the modified river die-away method from May 20 to July 29, 1999, the biodegradation rate was determined in Nakdong (A) and Kumho(B) River. The residual percentages of phosphamidon were 74.9%, 68.8% and 62.7% in control, A and B samples 7 days after applicaton, respectively. Biodegradation constants and half-lives of phosphamidon were 25.1%, 21.9% and 11.9% in control, A and B samples 7 days after application. Biodegradation constants and half-lives of profenofos were 0.0005 and 58.4 days in A, 0.0013 and 21.6 days in B, respectively. The biodegradation rates of phosphamidon and profenofos were higher in the Kumho River (B) than in the Nackdong River(A). The strains of microorganisms for the degradation of phosphamidon and profenofos were identified as Klebsiella pneumoniae, Aeromonas hydrophila and Acinetobacter calcoaceticus, all Gram-negative bacteria. In order to identify biodegradate products, the extracts of cultivates were analyzed by GC/MS. The mass spectra of biodegradate roducts of phosphamidon were at m/z 153 and 149, those of the profenofos were at m/z 208 and 240, respectively. It was suggested that the biodegradate metabolites of phosphamidon were O, O-dimethyl phosphate(DMP) and N, N-diethylchloroacetamide, those of profenofos were 4-bromo-2-chlorophenol and O-ethyl-S-propyl phosphate.

  • PDF

Effect of Heat, Pressure, and Acid Treatments on DNA and Protein Stability in GM Soybean (GM 콩 DNA와 단백질의 안정성에 대한 열, 압력 및 산 처리의 영향)

  • Pack, In-Soon;Jeong, Soon-Chun;Yoon, Won-Kee;Park, Sang-Kyu;Youk, Eun-Soo;Kim, Hwan-Mook
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.677-682
    • /
    • 2004
  • Debates on safety of genetically modified (GM) crops have led to mandatory-labeling legislation of GM foods in many countries including Korea. Effects of heat, pressure, and acid treatments on degradation of DNAs or proteins in GM soybean at levels below detection limits of qualitative PCR and lateral flow strip test (LFST) methods were examined. Results showed that genomic DNAs and proteins were degraded into fragment sizes no longer possible for detection of inserted gene depending on thermal, or thermal and pressure treatment period. Detectaability of LFST for toasted meal increased in weakly treated soybean. DNA and protein detection methods were barely effective for detection of GM ingredient after $121^{\circ}C$ and 1.5 atmospheric treatment for 20 min. These results will be useful in determining GM labeling requirements of processed foods.

Comparison of Network-RTK Surveying Methods at Unified Control Stations in Incheon Area (인천지역 통합기준점에서 Network-RTK 측량기법의 비교)

  • Lee, Yong Chang
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.469-479
    • /
    • 2014
  • N-RTK(Network based RTK) methods are able to improve the accuracy of GNSS positioning results through modelling of the distance-dependent error sources(i.e. primarily the ionospheric and tropospheric delays and orbit errors). In this study, the comparison of the TTFF(Time-To-Fix-First ambiguity), accuracy and discrepancies in horizontal/vertical components of N-RTK methods(VRS and FKP) with the static GNSS at 20 Unified Control Stations covering Incheon metropolitan city area during solar storms(Solar cycle 24 period) were performed. The results showed that the best method, compared with the statics GNSS survey, is the VRS, followed by the FKP, but vertical components of both VRS and FKP were approximately two times bigger than horizontal components. The reason for this is considered as the ionospheric scintillation because of irregularities in electron density, and the tropospheric scintillation because of fluctuations on the refractive index take the place. When the TTFF at each station for each technique used, VRS gave shorter initialization time than FKP. The possible reasons for this result might be the inherent differences in principles, errors in characteristics of different correction networks, interpolating errors of FKP parameters according to the non-linear variation of the dispersive and non-dispersive errors at rover when considering both domestic mobile communication infra and the standardized high-compact data format for N-RTK. Also, those test results revealed degradation of positing accuracy, long initialization time, and sudden re-initialization, but more failures to resolve ambiguity during space weather events caused by Sunspot activity and solar flares.

Physicochemical Characteristics of Silk Fibroin Degummed by Protease in Bacillus licheniformis I. Physicochemical Characteristics of Degummed Silk Fiber (Bacillus licheniformis 단백질 분해 효소에 의한 정연 견사의 특성 I. 정연 견사의 이화학적 특성)

  • 김영대;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.34 no.2
    • /
    • pp.41-51
    • /
    • 1992
  • In this thesis, both soap and enzymatic degumming method were adopted and the optimum degumming conditions were obtained. Difference between the two degumming methods in silk fiber state was investigated and analyzed on the basis of the results of physical testings, polarizing microscopy, scanning electron microscopy, viscosity measurement, (${\alpha}$$\varepsilon$) amino group contents measurement, birefringence measurement, amino acid analysis, thermal analysis, infrared spectroscopy and x-ray diffraction analysis. The results obtained were summarized as follows; Physical test results of the degummed silk fiber showed that the tenacity and the elongation of enzymatic degummed silk fiber were lower than those of soap degummed fiber. But SEM observation and amino acid analysis showed almost the same tendency in the two degumming methods. The viscosity of enzymatic degummed silk fiber was lower than that of soap degummed fiber, but (${\alpha}$$\varepsilon$) amino group contents was higher in the enzymatic degummed fiber. It can be suggested that the enzymatic degummed silk fibroin was more degraded than the soap degummed fibroin. The birefringence, endothermic temperature of DSC spectrum, IR crystallinity and X-ray lateral order factor of enzymatic degummed silk fiber were higher than those of soap degummed fiber. It seems that the enzymatic degummed silk fiber has the higher crystallinity than that of soap degummed one according to the above results. However, it can be inferred that these differences between soap and enzymatic degummed fiber would be lessened if pretreatment and aftertreatment were included in the enzymatic degumming process.

  • PDF

Inelastic Behavior of Post-tensioned Wide Beam System with different Reinforcement ratios within Column core (포스트텐션을 도입한 넓은 보에서 기둥 폭 내부에 배근된 보강재의 정착비에 따른 비탄성 거동 평가)

  • Choi Yun-Cheul;Lim Jae-Hyung;Moon Jeong-Ho;Lee Li-Hyung;Kwon Ki-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.85-94
    • /
    • 2005
  • Post-tensioned Precast concrete System(PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with floor concrete cast on the PC shell beam and post-tensioning. The purpose of this paper is to evaluate the response of PPS interior beam-column joint subjected to cyclic lateral loading. To this end, an experimental investigation was performed with three half-scale specimens of interior connection. The design parameters are the amount of beam reinforcement placed inside the joint core. The test results showed that cracks were distributed well without my significant degradation of strength and ductility. Also, it was found that the prestressing may affect to alter the torsional crack angle. And the specimens sufficiently resist up to limiting drift ratio of 0.035 in accordance with the provisional by ACl of acceptance criteria for concrete special moment frames.

Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가)

  • You, Young-Jun;Park, Young-Hwan;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.491-497
    • /
    • 2014
  • The corrosion of steel reinforcement in reinforced concrete bridge decks significantly affects the degradation of the capacity. Due to the advantageous characteristics such as high tensile strength and non-corrosive property, fiber reinforced polymer (FRP) has been gathering much interest from designers and engineers for possible usage as a alternative reinforcement for a steel reinforcing bar. However, its application has not been widespread, because there data for short- and long-term performance data of FRP reinforced concrete members are insufficient. In this paper, seven full-scale decks with dimensions of $4000{\times}3000{\times}240mm$ were prepared and tested to failure in the laboratory. The test parameter was the bottom reinforcement ratio in transverse direction. The decks were subjected to various levels of concentrated cyclic load with a contact area of $577{\times}231mm$ to simulate the vehicle loading of DB-24 truck wheel loads acting on the center span of the deck. It was observed that the glass FRP (GFRP) reinforced deck on a restraint girder is strongly effected to the level of the applied load rather than the bottom reinforcement ratio. The study results showed that the maximum load less than 58% of the maximum static load can be applied to the deck to resist a fatigue load of 2 million cycles. The fatigue life of the GFRP decks from this study showed the lower and higher fatigue performance than that of ordinary steel and CFRP rebar reinforced concrete deck. respectively.

Dynamic shear behavior of geosynthetic-soil interface considering thermalchemical factors (열-화학적 인자를 고려한 복층터널의 지반-토목섬유의 접촉면 전단거동)

  • Jang, Dong-In;Kwak, Chang-Won;Park, Inn-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.213-220
    • /
    • 2016
  • The needs for the utilization of space in the urban ara due to the increasing population and traffic volume. A Double-deck tunnel can be an appropriate solution. Geosynthetics are inevitably installed between ground and tunnel lining, therefore, geosynthetic-soil interface is also comprises. Dynamic shear behavior of geosynthetic-soil interface affects the dynamic behavior of tunnel, and experimental study is required since the behavior is very complicated. In this study, chemical factors such as acid and basic element in the groundwater and temperature are considered in the laboratory test. Multi-purpose Interface Apparatus(M-PIA) is utilized and submerging periods are 60 and 960 days. Consequently, dynamic shear degradation of geosynthetic-soil interface considering chemical and thermal factors are verified.