• Title/Summary/Keyword: degassing

Search Result 111, Processing Time 0.024 seconds

HYDROGEN DECREPITATION AND MAGNETIC PROPERTIES OF $Sm_{2}Fe_{17}-TYPE$ ALLOY MODIFIED WITH A SMALL ADDITION OF Nb

  • Kwon, H.W.;Harris, I.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.432-436
    • /
    • 1995
  • The hydrogen decrepitation behaviour of the $Sm_{2}Fe_{17} alloy containing 4at%Nb was examined by means of DTA and SEM metallography, and the magnetic properties of the alloy were studied by means of VSM or TMA. It has been found that a simple hydrogenation and degassing treatment for the alloy caused a poor hydrogen decrepitation. The cycle treatment consisting of repeated hydrogenation and degassing, however, caused a severe hydrogen decrepitation with a combination of intergranular and transgranular failure. The disproportionation temperature of the hydrogenated $Sm_{2}Fe_{17}-type alloy was enhanced significantly by small addition of Nb. It has also been found that the Curie temperature of $Sm_{2}Fe_{17} matrix phase in the Nb-containing alloy has been enhanced by the hydrogenation, and this was attributed to the increase in interatomic distance between the neighbouring iron atoms caused by the interstitial occupancy of the hydrogen atom into the $Sm_{2}Fe_{17}-type lattice. The magnetisation of the $Sm_{2}Fe_{17} alloy containing Nbwas found to be lower than that of the Nb-free alloy, and this was explained by the dilution effect due to the presence of the paramagnetic $Sm_{2}Fe_{17} phase.

  • PDF

Quality Changes of Retorted Samgyetang During Storage Depending on the Degassing Methods (탈기 포장 방법에 따른 레토르트 삼계탕의 저장 중 품질 변화)

  • Jang, Min Jun;Lee, Jin Ho;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.2
    • /
    • pp.67-73
    • /
    • 2013
  • This study investigated the quality changes of Samgyetang during storage, resulting from various degassing methods used at the packaging stage. Three different samples were prepared, one without any treatment (CON), a second with reduced head space volume by squeezing the pouch (RHS), and a third by flushing with nitrogen gas (NGF). These were retorted at $120^{\circ}C$ for 65 min under the F-value of approx. 8.0, and stored at $25^{\circ}C$ for 9 months. The oxygen ratio in the head space and the dissolved oxygen content of NGF samples tended to be lower than those of other samples over the storage period. Compared to the CON, the acid values of NGF and RHS samples were lower than the CON from month 3 and 6 (p<0.05). During storage, volatile basic nitrogen values of NGF and RHS samples increased slowly compared to the CON. To delay quality deterioration and extend the shelf-life of Samgyetang products, the reduction of oxygen content in the head space of the retort pouch (preferably by flushing with nitrogen gas) is recommended, even though no significant differences in sensory evaluation were observed among the samples during 9 months of storage (p>0.05).

  • PDF

Preparation of hollow fiber membrane for degassing by melt spinning and drawing method. (용융방사와 연신에 의한 용존기체 제거용 중공사 분리막의 제조)

  • 김승일;이의소
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.185-186
    • /
    • 2003
  • 막을 이용한 분리기술은 다양한 종류의 혼합물에서 원하는 물질을 분리 정제하는 기술로 여기에는 고-액, 액-액, 기-액분리가 모두 포함된다 현재까지 분리공정은 주로 여과, 증류, 추출, 흡착등 방법이 있으나 에너지소비가 많고, 설비투자비가 많이 들며 효율이 낮아 비경제적이라는 문제점을 가지고 있고 이와 같은 문제점을 해결하기 위하여 최근 주목받고 있는 기술이 막을 이용한 분리기술이다. 막을 이용한 분리기술의 장점은 앞서 언급한 바와 같이 에너지소비와 설비비를 최소화하면서도 고효율의 분리효과를 얻을 수 있다는 점에 있다. (중략)

  • PDF

Sensitive Determination of Felodipine in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeon-Jin;Lee, He-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.283.2-283.2
    • /
    • 2003
  • This study established a highly sensitive novel quantification method for detecting felodipine in human plasma using LC-MS/MS. The mobile phase used after degassing was composed of 1 mM ammonium acetate and acetonitrile (20:80, pH 6.0), with flow rate of 200 uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

Determination of Glimepiride in Human Plasma by LC-MS/MS

  • Kim, Ho-Hyun;Roh, Hyeong-Jin;Lee, Hee-Joo;Han, Sang-Beom
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.282.1-282.1
    • /
    • 2003
  • This study established a sensitive novel Quantification method for detecting glimepiride in human plasma using LC-MS/MS for pharmacokinetic studies. The mobile phase used after degassing was composed of 10 mM ammonium acetate and acetonitrile (20:80, pH 3.0), with flow rate of 200uL/min. One mL plasma were pipetted into glass tubes and spiked with 0.1 mL of internal standard solution. (omitted)

  • PDF

MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE

  • Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.120-132
    • /
    • 1998
  • This stusy was to investigate the marginal fitness of porcelain-fused-to- metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento- enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing. body porcelain firing, and glazing, and measuring sites were 4. (midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus. Japan) was used under ${\times}250$ magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.

  • PDF

A Comparative Study on the Marginal Fit between Castable Ceramic(Dicor) Crowns and Metal-Ceramic Crowns (주조도재관과 도재전장주조관의 치경부 변연적합도에 관한 비교 연구)

  • Kim, Jeong-Ho;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 1988
  • The recently introduced castable glass ceramics incorporate properties characteristic of natural teeth and they are regarded as an ideal material to restore lost tooth structure. The purpose of this study was to compare the marginal fit of castable ceramic crown with that of the metal-ceramic crown in the process of heat treatment. Two master dies for castable ceramic crowns and metal-ceramic crowns were fabricated from being cast with the base metal. Each master die was duplicated with addition silicone and hard stone. Ten castable ceramic crowns were made on each hard stone die and their marginal openings were measured three times first, after casting; second, after ceramming; third, after shading. The other ten metal-ceramic crowns were made on each hard stone die and their marginal openings were measured three times : first, after casting; second, after degassing; third, after porcelain veneering. Each crown was seated on its master die with the constant force delivered by loading jig. And then, marginal openings were measured on four locations by optical projector at X50 magnification. The results were as follows: 1. The mean marginal openings of castable ceramic crowns were $31.1{\pm}12.7{\mu}m$ after casting; $44.6{\pm}12.8{\mu}m$ after ceramming; $51.2{\pm}16.8{\mu}m$ after shading. 2. The mean marginal openings of the metal-ceramic crowns were $26.2{\pm}13.8{\mu}m$ after casting; $29.8{\pm}10.3{\mu}m$ after degassing; $38.0{\pm}14.5{\mu}m$ after porcelain veneering. 3. There was significant increase in the marginal opening of castable ceramic crowns after ceramming, while metal-ceramic crowns sho(wed significant increase after porcelain veneering (p<0.05). 4. Marginal fit of metal-ceramic crown was better than that of castable ceramic crown (p<0.01).

  • PDF

SEM/EDS Evaluation of Gold Bonding Agent Applied on Non-precious Alloys and Cast CP-Ti (도재 소부용 비귀금속 합금과 티타늄에 적용한 Gold Bonding Agent의 전자현미경적 평가)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.9 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • The purposed of this study was to investigate the effect of Gold bonding agent as intermediate layer between metal substrate and ceramic coating. Gold bonding agent used to seal off any surface porosity, to mask the greyish color of the metal, and to provide an underlying bright golden hue to the ceramic coverage. The adhesion between metal substrate and ceramic is related to diffusion of oxygen during ceramic firing. The oxide layer produced on non-precious alloy anti titanium was considered to have a potentially adverse effect on metal-ceramic bonding. The oxidation characteristics of titanium and non-precious alloys are the main problem. Every group were divided into test and control groups. Control groups are carried out process of degassing for product oxide layer. Au coating was applied on each Ni-Cr, Co-Cr alloys and cp-Ti specimens with difference surface condition or degassing. Specimens surfaces and cutting plane was characterized by SEM/EDS. Results suggested that Au coating is effective barriers to protect metal oxidation during ceramic firing.

  • PDF

Photosynthesis and Respiration (P&R) Analyzer Analysis Optimization for Microalgal Activity Evaluation (미세조류 활성도 평가를 위한 Photosynthesis and Respiration (P&R) Analyzer 분석조건 최적화)

  • Huh, Jae-Hee;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.449-457
    • /
    • 2021
  • Photosynthesis and respiration rate of microalgae are important factors during advanced wastewater treatment research using microalgae, There are several equipments and measurement methods for measuring photosynthesis and respiration, with different challenges that occur during pretreatment and stabilization of the analysis process. Therefore, in this study, for accurate Photosynthesis and Respiration (P&R) analyzer measurement, the analysis process was divided into pre-processing, DO stabilization, and analysis stages and each was optimized to enable accurate evaluation. For this purpose, the effect of DO saturation of the sample on P&R analysis, DO stabilization according to the degassing flow rate, and photoinhibition of the OD level on photosynthesis was investigated. Based on our study results, when DO was supersaturated, photosynthetic efficiency decreased due to photorespiration, making it inappropriate as a P&R sample. In addition, 0.5 L-N2/min level was the optimal nitrogen degassing flow rate for DO desaturation. The inhibition of photosynthetic efficiency by self-shading caused by the increase in OD was observed from OD 2.0, and it was found that P& R analysis is preferably performed on samples with OD less than 2.0. In addition, based on the above three optimization results, an optimized P&R Analyzer instruction for accurate P&R analysis was also presented.

Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples (고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가)

  • Minseok Song;Soohyeon, Moon;Gitak Chae;Jun-Hwan Bang
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.