• Title/Summary/Keyword: defrost

Search Result 63, Processing Time 0.023 seconds

Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors (광센서를 이용한 제상제어 방법에 대한 타당성 검토)

  • Jeon, Chang-Duk;Kim, Dong-Seon;Lee, Seung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3389-3395
    • /
    • 2014
  • Conventional methods, such as the clock time control method and temperature difference control method, for defrost control often encounter mal-defrost and a waste of energy. Therefore, a more efficient method is needed to control defrosting precisely. A photoelectric sensor unit consisting of an emitter and a collector was installed in the front of outdoor heat exchanger. Accurate defrost control was performed by monitoring and using the change in output voltage according to the presence of frost. In this study, experiments were performed to determine if the performance and characteristic curves obtained using the clock time control method can be reproduced using a photoelectric sensor under the heating and defrosting capacity test condition described at KS C 9306. The output voltage of the phototransistor (receiver) and heating capacity, power consumption, and surface temperature of the outdoor heat exchanger, were compared. The results showed that photoelectric sensors can be used as a defrost control method. On-off control timing of the clock time defrosting method was in good agreement with those predicted by the output voltage of the photoelectric sensor.

Numerical defrost analysis of automobile windshield using enthalpy method (열용량법을 이용한 자동차 전방 유리면의 제상성능 해석)

  • Hwang J. E.;Park M. S.;Park W. G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.176-180
    • /
    • 2001
  • For windshield defrosting, flow analysis of inner room(vehicle) and heat conduction on the windshield surface are undertaken. Simulation for defrosting enthalpy method is usedand verification of heat and fluid flow analysis for room is done in cavity flow. The defrosting process is three dimensional phenomena and phase is changing. The result of defrosting analysis are well presenting the phase change and these results offer basic design data for defrosting phenomena.

  • PDF

Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank (냉동탑차의 Thermobank 열저장 매체에 따른 냉각성능 비교)

  • Mun, Je-Cheol;Choi, Kwang-Il;Oh, Jong-Taek;Kim, Jai-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.810-814
    • /
    • 2009
  • A experimental study of a high efficiency transport refrigeration system for sliced-raw fish transportation is presented in this paper. The refrigeration system, that is powered by the car engine, is equipped with heat storage for reverse cycle-hot gas defrost; the stored heat is used during defrost cycle of the system. The heat storage has size $400(L){\times}350(W){\times}250(H)\;mm$ and made of fin-tube heat exchanger. System performance and container operating conditions are experimentally investigated and analyzed under cooling and defrosting conditions with heat storage materials. The water is faster about 30% than paraffin in cooling-down time of heat storage materials with load and unload.

  • PDF

Quality Changes of Frozen Scallop[Patinopecten yessonensis(Jay)] Stored in theDomestic Refriogerator (가정용 냉장고에서 동결저장 중의 가리비의 품질 변화)

  • 김상무
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.3
    • /
    • pp.450-455
    • /
    • 1997
  • Scallop, Patinopecten yessonensis(Jay), cultivated in the cold east coast of Kwangwon region, Korea, is expected to be producted to about 50,000 tones in 2000 year. Freezing is one of the most effective methods applied for soraging seafoods. But, the domestic refrigerator with an automatic defrost system shows the temperature fluctuation during defrosting, thus might result in the deterioration of the frozen foods. In this study, the domestic refrigerator with an automatic defrost system, temperature fluctuation from -18 to -5$\pm$1$^{\circ}C$ and fluctuation intervals from 16 to 20 hr, was used for storing scallop. pH was decreased rapidly after 3 month storage, while the content of amino nitrogen was increased continuously. The TMA content of open state was increased very rapidly on 3 month storage and then increased slowly, whereas that of vinyl package increased slowly. The VBN content was increased almost constantly with no significant differences between storage methods. The TBA content was increased up to 3 month storage with the higher value in open state than vinyl package in the beginning periods of storage, and then decreased very rapidly. The number of total viable cell was increased continuously during storage with higher number in open state than vinyl package. The estimated shelf-lives of frozen scallop with open state and vinyl package stored at -18$^{\circ}C$ in the domestic refrigerator with an automatic defrost system were 3.55 and 3.78 months, respectively.

  • PDF

Performance Evaluation of a Defrosting System Using the Condensation Heat of a Refrigerator in Cold Storage (저온창고에서 냉동기 응축폐열을 이용한 제상시스템 성능평가)

  • Park, Chunwan;Lee, Donggyu;Im, Kwanbin;Kang, Chaedong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • In a cold chain, the refrigerator is also employed for defrosting, by using an electric heater, which consumes 15% of the power for the system operation. In this study, the condensation heat of the refrigerant was suggested as the heat source of defrosting heat, instead of that from an electric defrost heater. The heat for defrosting was stored to a phase change material (PCM, NMP : $52^{\circ}C$) in thermal storage, and was periodically supplied to the evaporator by a circulation loop of brine. As a result, a defrost time by the PCM was obtained that was less than or equal to that by the electric heater. Moreover, power consumption during defrosting was saved by up to 99% of that of the electric heater.

3-D Numerical analysis of flow and temperature field of automobile cabin by discharged air from defrost nozzle (Defrost nozzle의 토출 공기에 의한 승용차 실내 유동장 및 온도장 해석)

  • Kang K. T.;Park K. S.;Park W. G.;Jang K. R.
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.25-32
    • /
    • 2002
  • The velocity and temperature profiles in the cabin of the automobile affect greatly the comfortableness of passengers. In this paper, the three dimensional flow and temperature analysis in the cabin of real automobile have been peformed. The three dimensional Navier-Stokes equation solver was validated by comparing with the other numerical data of a 1/5 scale model. The temperature field of cavity was also analyzed for the validation of energy equation solver. After the code validation, the numerical analysis of real field of flow and temperature of an automobile was peformed and the present result provides the insight of flow and temperature field of the inside of cabin.

3-D Numerical analysis of flow and temperature field in the cabin of the automobile with defrost nozzle discharged air (Defrost nozzle의 영향을 고려한 3차원 승용차 실내 유동 및 온도 해석)

  • Kang Kyu-Tae;Bae In-Ho;Hwang Ji-Eun;Park Warn-Gyu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.31-36
    • /
    • 2001
  • The velocity and temperature profiles in the cabin of the automobile affect greatly to the comfort of the passenger. In this paper, the three dimensional flow and temperature analysis in the cabin of the automobile which is geometrically complicated was performed to investigate and predict the velocity and temperature profile. The three dimensional Navier-Stokes code used in this case was validated by performing of a 1/5 experimental scale model vehicle flow anal)rsis successfully. The temperature field of cavity was analyzed for Energy-equation code validation. The comparison of the results are made with the polished computational data and give a coincided one.

  • PDF

Effect of Frost and Defrost on the Operating Characteristics of Refrigeration System (착상과 제상이 냉동장치의 운전특성에 미치는 영향)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • This study was investigated the effect on operating characteristics of apparatus according to frosting and defrosting to develop of new defrosting equipment. The results showed as following. Frost was almost removed using the defrosting equipment with roll brush type that defrosting is possible under operating condition. Also, the temperature of compressor inlet, evaporator inlet and outlet showed higher value because of heat transfer resistance of cooling pipe frost comparing with defrosting condition. And the compressor work showed 10% lower and COP was presented 24% higher values than defrosting condition. Therefore, defrosting for cooling coil of refrigeration and low temperature storage was effected on operation and performance characteristics of equipment. This highly effects on real refrigeration apparatus which is operated in year-around.

FLOW AND TEMPERATURE ANALYSIS WITHIN AUTOMOBILE CABIN BY DISCHARGED HOT AIR FROM DEFROST NOZZLE

  • Park, W.G.;Park, M.S.;Jang, K.L.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.139-143
    • /
    • 2006
  • As an automobile tends to be high grade, the needs for more luxurious interior and comfortable HVAC system are emerged. The defrosting ability is another major factor of the performances of HVAC system. The present work is to simulate the flow and the temperature field of cabin interior during the defrost mode. The three-dimensional incompressible Navier-Stokes equations and energy equation were solved on the multi blocked grid system by the iterative time marching method and AF scheme, respectively. The present computations were validated by the comparison of the temperature field of a driven cavity and velocity field of 1/5 model scale of an automobile. Generally good agreements were obtained. By the present computation, the complicated features of flow and temperature within the automotive cabin interior could be well understood.

Experimental Study for Development of Air Eject Defrost Equipment (공기분사식 제상장치 개발에 관한 실험적 연구)

  • Han, In-Geun;Kim, Chang-Yeong;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.