• Title/Summary/Keyword: deformed bar

Search Result 125, Processing Time 0.031 seconds

Study on the Effect on the Development Design of Headed Deformed Bars by change of ACI 318-19 (ACI 318-19 변경에 따른 확대머리철근 정착설계의 영향분석)

  • Lee, Byung Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.110-111
    • /
    • 2019
  • In ACI 318-19 published recently, the conditions and development length equation to use the headed deformed bars were changed considerably. Although the use of the larger-diameter(No.14 and 18) headed deformed bars isn't yet permitted, the use of the high strength(80,000psi) headed deformed bars is permitted and the effect of bar-diameter($d_b$) on the development length is increased considerably. Therefore, structures using larger-diameter headed deformed bars will be expected to be affected by this code change. We will study the effect of the code change on the development design and find out the design optimization method to minimize the effect of the changed conditions and development length equation.

  • PDF

Bond strength prediction of steel bars in low strength concrete by using ANN

  • Ahmad, Sohaib;Pilakoutas, Kypros;Rafi, Muhammad M.;Zaman, Qaiser U.
    • Computers and Concrete
    • /
    • v.22 no.2
    • /
    • pp.249-259
    • /
    • 2018
  • This paper presents Artificial Neural Network (ANN) models for evaluating bond strength of deformed, plain and cold formed bars in low strength concrete. The ANN models were implemented using the experimental database developed by conducting experiments in three different universities on total of 138 pullout and 108 splitting specimens under monotonic loading. The key parameters examined in the experiments are low strength concrete, bar development length, concrete cover, rebar type (deformed, cold-formed, plain) and diameter. These deficient parameters are typically found in non-engineered reinforced concrete structures of developing countries. To develop ANN bond model for each bar type, four inputs (the low strength concrete, development length, concrete cover and bar diameter) are used for training the neurons in the network. Multi-Layer-Perceptron was trained according to a back-propagation algorithm. The ANN bond model for deformed bar consists of a single hidden layer and the 9 neurons. For Tor bar and plain bars the ANN models consist of 5 and 6 neurons and a single hidden layer, respectively. The developed ANN models are capable of predicting bond strength for both pull and splitting bond failure modes. The developed ANN models have higher coefficient of determination in training, validation and testing with good prediction and generalization capacity. The comparison of experimental bond strength values with the outcomes of ANN models showed good agreement. Moreover, the ANN model predictions by varying different parameters are also presented for all bar types.

Investigation of Through-thickness Microstructural Evolution in a 600 MPa-Grade Reinforced Steel Bar Manufactured by Tempcore Process (Tempcore 공정을 통해 제조된 600 MPa급 철근의 두께방향 미세구조 변화 분석)

  • Jiwon Park;Hyunji Kim;Singon Kang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.6
    • /
    • pp.367-373
    • /
    • 2023
  • 600 MPa-grade deformed bar samples were manufactured by conventional hot rolling and subsequent Tempcore heat treatment processes. Considering the short-time water quenching step of the Tempcore process for hot-rolled steel, it is inevitable that the temperature profile of the deformed bar depends strongly on its position throughout the sample thickness. As a result, its microstructure can be easily divided into two regions, the surface and the core regions. The former is expected to have a fresh martensite microstructure under rapid cooling conditions, but self-tempering occurs due to the intense heat flow from the hot core region after the process. The latter is generally known to exhibit a mixed microstructure of ferrite and pearlite due to its slow cooling rate. In this study, detailed microstructural evolutions were examined through the thickness direction. The large variation of the microstructure through the thickness direction in the deformed bar samples is partly due to the easy carbon diffusion from the limited additions of alloying elements.

The Technology Development for applying the High Strength Headed Deformed Bar to the Nuclear Power Plant Structures (원전구조물의 확대머리 고강도철근 적용기술 개발)

  • Lee, Byung-Soo;Bang, Chang-Joon;Lee, Han-Woo;Lim, Sang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.273-275
    • /
    • 2013
  • If the mechanical development is applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the yield strength and diameter of the re-bar. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

Inplane Flexural Behavior of Concrete Walls Reinforced by Welded Wire Fabric (용접철망 콘크리트 벽체의 면내 휨거동 연구)

  • Kim, Dae-Joong;Kim, Woo;Yang, Ji-Soo;Yoon, Young-Ho;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.136-141
    • /
    • 1993
  • 8 Wall specimens (1/2 scaled) used welded wire fabric (Ф=6mm) and ordinary deformed reinforcement(D6) of which their ultimate tensile strength were almost same were tested to investigate the inplane-flexural behavior. Test results show that : 1. The wall strength with welded wire fabric was 20% less than that with deformed bar. 2. The wall ductility ratio of welded wire fabric was 1/3 times than that of deformed bar, approximately. 3. It is recommened that lap splice of welded sire fabric should be avoided in critical fracture zone.

  • PDF

A Study of the Plastic Deformation in Axisymmetric Combined Extrusion (축대칭 복합압출공정의 소성변형 연구)

  • 한철호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2005-2015
    • /
    • 1994
  • An analytical method based on the upper bound approach for the cup-bar axisymmetric combined extrusion is presented to determine the deformation zones as well as extrusion load and deformed geometry in the early stage. A new kiematically admissible velocity field is derived by the appropriate transformation of the original velocity field and applying the flow function approach. The derived velocity field is directly related to the boundary function for the plastically deforming zones and the parameter controlling the flow direction to the forward part or backward part. Experiments are carred out with the annealed aluminum 2024 at room temperature for the various area reductions. The workhardening effect is considered in the formulation as a function of the height ratio between the deformed billet and the orighinal billet to calculate the extrusion pressures. The theoretical predictions for the extrusion loads and deformed configuration are in good agreement with the experimental results.

ACI 349 Code Change to Use the Gr.80 Headed Deformed Bars in Nuclear Power Plant Structures (Gr.80 확대머리철근의 원전구조물 적용을 위한 ACI 349 코드개정에 관한 연구)

  • Lee, Byung Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.200-201
    • /
    • 2017
  • Generally, a lot of reinforcements are used in nuclear power plant concrete structures, and it may cause several potential problems when concrete is poured. Because of the congestion caused by hooked bars, embedded materials, and other reinforcements, it is too difficult to pour concrete into structural member joint area. The purpose of this study is to change ACI 349 Code for using the large-size(57mm) and high-strength(Gr.80) headed deformed bars instead of standard hooked bars in nuclear power plant concrete structures in order to solve the congestion problems.

  • PDF

An Experimental Study on the Bond Characteristics of Glass Fiber Reinforced Polymer Rebar (GFRP Rebar의 부착성능에 관한 실험적 연구)

  • Park Ji-Sun;You Young-Chan;Park Young-Hwan;Choi Ki-Sun;Kim Hyeong-Yeol;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.124-127
    • /
    • 2004
  • This study is to investigate the bond characteristics of glass fiber reinforced polymer(GFRP) reinforcing bars in concrete by pullout test experimentally. Three different types of GFRP bars with different surface deformations were considered in this study. Also, standard deformed steel reinforcing bar with or without epoxy-coating were included for the comparisons of bond strength. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendation of CSA(Canadian Standards Association) Standard S806-02. From the test results, it was found that small surface indentations contributed to increase the bond strength of GFRP bar significantly. Based on the limited test results till now, the bond strength of GFRP bar with sand-coated deformation commercially available in foreign market is around $80\%$ of that of steel deformed bars.

  • PDF

Study on the Development Design Criteria of High Relative Rib Area bars (높은 마디면적비 철근의 부착강도에 따른 정착설계 연구)

  • Park, Sung-Gyu;Hong, Geon-Ho;Choi, Oan-Chul;Hong, Gi-Suop
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.270-273
    • /
    • 2006
  • Bond between reinforcing bar and the surrounding concrete is made up of three components. There are chemical adesion, friction, and mechanical interaction between the rib of the bar and the surrounding concrete. bond of deformed bars depends primarily on the beraing of rib deformation anainst the surrounding concrete. The final objective of the study is to enhance structural stability, and workability thorough increasing the bond strength between deformed bar and surrounding concrete. The results of this study will be used to shorten bond and development length by $20{\sim}30$ percent and it will facilitate to use of high strength and high-relative rib area bars.

  • PDF

Development and Performance Evaluation of the Shear Connector of Composite Beam with Vertical Bars (직봉의 기능을 포함한 합성보의 전단연결재 개발과 성능평가)

  • Kim, Sang-Seup;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.725-736
    • /
    • 2011
  • In a composite beam, a shear connector is installed to resist the horizontal shear on an interface between steel beams and reinforced concrete slabs. The steel-wire-integrated deck plate slab is commonly used at the wide section beam. Then vertical bars are installed at the upper wire of the ends of the steel truss girder to ensure safety during the construction. The new type of shear connector is made of deformed bar and steel plates, and must function as vertical bars but must have higher shear capacity. This paper examines the ways to develop and utilize this new shear connector. From the push-out experiments, a shear connector made of a continuous deformed bar and steel plate showed a higher shear capacity and ductility than a ${\phi}16$ stud connector, and functioned as a vertical bar.