• 제목/요약/키워드: deflection measurement

검색결과 225건 처리시간 0.027초

좌표측정 센서시스템을 이용한 실험용 보의 처짐 계측 (Beam deflection measurement using coordinate sensor system)

  • 노태성;임홍철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.300-301
    • /
    • 2014
  • Measurement of beam deflection is a common procedure to determine proper behavior of the structure. Either LVDT (Linear Variable Displacement Transformer) or strain gauge is usually used in experiments. A newly developed coordinate reading measurement system can be also applied for the deflection measurements. In this study, an experimental measurement was made on a laboratory size beam specimen to examine the possibility of the use of such coordinate measurement system. Results have shown the possibility of utilizing the new system for beam deflection measurement.

  • PDF

FRC의 휨인성 평가시 외부변형과 불안정성의 영향 및 처리방안 (The Influence and Treatment Method of Extraneous Deformation & Unstability on the Flexural Toughness of FRC)

  • 김경수;김남욱;임정환;배주성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.119-128
    • /
    • 2002
  • This study discusses the issues related to the accuracy of deflection measurement and unstable energy in the testing of FRC. Some deflection methods may include large extraneous deformations. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and inaccurate toughness evaluation can result from this faulty curve. Some load-deflection curve of FRC may be attributed to unstable region of the load-deflection curve. If the unstable region is not correctly evaluated toughness indices from the curve would inappropriately represent true indices. In this paper, the discussion will focus on the effects of the deflection measuring system both on the measurement of the load-deflection response of FRC and the evaluation of FRC toughness and the effects of the unstable region and the management method of unstable region on toughness evaluation of FRC. It is observed that ASTM toughness indices which is based on measured deflection at first cracking is influenced significantly by extraneous deformation of deflection measurement. Extraneous deformation in deflection measurement, however result in negligible errors in toughness evaluation if JSCE and JCI definitions are used.

외부변형이 섬유보강콘크리트의 인성에 미치는 영향 (Influence of Extraneous Deformation on the Toughness of Fiber Reinforced Concrete)

  • 김경수;고영주;임정환;배주성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권1호
    • /
    • pp.111-120
    • /
    • 2000
  • This study discusses the issues related to the accuracy of deflection measurement in the testing of FRC. Some deflection methods may include large extraneous deformations. such as local crushing at the loading points, elastic and inelastic deformations of the loading fixture, etc. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and incorrect toughness evaluation can be reached on the basis of this faulty curve. In this paper, the discussion will focus on the effects of the deflection measuring system on both the measurement of the load-deflection response of FRC and the evaluation of FRC toughness. It is observed that ASTM toughness indices which is based on measuring deflection at first cracking is influenced significantly by extraneous deformation in deflection measurement. But extraneous deformation in deflection measurement result in negligible errors in toughness evaluation using JSCE and JCI definition. However, in order to evaluate toughness accuracy, it is desirable to use net load-deflection curve eliminated extraneous deformation.

  • PDF

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

  • Park, Sang-Joon;Kim, Hyoung Joo;Noh, Jaewoo
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.277-281
    • /
    • 2012
  • We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

PSD를 이요한 AFM용 미세 탐촉자의 변위측정장치 (Cantilever deflection measurement system for AFM with PSD)

  • 김홍준;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.31-35
    • /
    • 2000
  • A cantilever deflection measurement system for AFM(atomic force microscope) was constructed by the laser deflection method using LEP type PSD. Design process including sensitivity analysis was presented and the performance of the system was demonstrated by several experiments using a sample specimen with 50nm-step on the surface. The measured displacement-amplification-factor showed good agreement with the expected one with about 8% deviation. The step height measurement data were compared to what were acquired by commercial AFM, and the result showed that there were about 5nm-deviation between the two data. These results satisfies our expectation in the stage of system design.

  • PDF

광열편향법을 이용한 이방성 재료의 열전도계수 측정에 관한 이론적 연구 (A Theoretical Study for the Thermal Conductivity Measurement of Anisotropic Material using Photothermal Deflection Spectroscopy)

  • 전필수;김현정;유재석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2465-2470
    • /
    • 2007
  • We have analyzed the three-dimensional thermal conduction in anisotropic materials using nonsymmetric-Fourier transforms. And a complete theoretical treatment of the photothermal deflection spectroscopy has been performed for thermal conductivity measurement in anisotropic medium. Thermal conductivity tensor was determined by the deflection angle and phase angle with the relative position between the heating and probe beams. The influence of the parameters, such as modulation frequency of the heating beam, the thermal conductivity tensor, was investigated.

  • PDF

연속 스캐닝 레이저 진동계 신호의 Hilbert 변환을 이용한 실험적 모드 해석 (Experimental Modal Analysis by Using Hilbert Transform of Signal from Continuous Scanning Laser Vibrometer)

  • 강민식;장태규;김호성
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권6호
    • /
    • pp.272-277
    • /
    • 2002
  • This paper deals with the vibration deflection shape measurement technique for a sinusoidally excited structure using a continuously scanning laser Doppler vibrometer (CSLV). The CSLV output signal is an amplitude-modulated vibration in which the excitation signal is modulated by the deflection shapes, and thus the deflection shapes of vibration defined along a scan line can be derived by the envelop and the phase information of the CSLV output signal. In this work, a Hilbert transform based approach has been proposed for measurement of deflection shapes. This technique is as simple as the demodulation technique and allows more convenient experimental settings than the Fourier transform approach. The feasibility of the proposed technique is illustrated along with results of experiment.

전이층을 가진 초고층건물의 기둥축소량 예측 및 현장계측 (Column Shortening prediction and Field measurement of Tall building with Transfer floor)

  • 송화철;조용수;정성진;윤광섭;이우호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.175-181
    • /
    • 2006
  • The prediction of time-dependent column shortening is essential for tall buildings considering both strength and serviceability aspects. The Column shortening of tall buildings with transfer floor should be calculated considering the long-term deflection of transfer girder. In this study, both the column shortening and the deflection of transfer girder of 45-story tall concrete building are predicted. The column shortening considering deflection of transfer girder are compared with the actual column shortening by field measurement.

  • PDF

레이저 간섭계에 의한 테이블의 처짐측정과 FEA에 의한 이의 검증 (A Study on the measurement of Table Deflection using Laser Interferometer and It's Inspection using FEA)

  • 이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.204-209
    • /
    • 1998
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics Stylus instrument method, STM, SEM, Laser interferometer method which are used for measuring the quasi-static error of machine tools. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general studies, people who works on the spot has many problems on the data value. Therefor we will help working more accurately on the spot by measuring, analyzing, displaying the deflection of the table and support shaft when we load on the table and the support shaft of machining center using laser interferometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tendency by verifing the tendency of the error measured through the comparison of the simulated error using ANSYS, a common finite element analysis program, which is able to measure heat deformation, material deformation, and error resulted form this study.

  • PDF