• 제목/요약/키워드: defect-correction method

검색결과 61건 처리시간 0.028초

Application of Homograft in the Surgical Correction of Complex Congenital Cardiac Malformations (선천성 복잡 심기형 환자의 외과적 교정술시 동종이식편의 적용에 관한 연구)

  • 지현근
    • Journal of Chest Surgery
    • /
    • 제28권11호
    • /
    • pp.1038-1044
    • /
    • 1995
  • We have been used cryopreserved homograft valves for right ventricular outflow tract[RVOT reconstruction since November 1993. The homograft valves were harvested from the hearts of brain dead patients or hearts of transplant recipients. There were 12 male and 10 female patients. Their ages ranged from 5 months to 13 years[mean age,39.2 $\pm$ 37.4 months and the weight ranged from 5 to 48kg [mean weight, 13.7$\pm$ 9. l kg . The diagnoses included pulmonary atresia with ventricular septal defect [n=14 , tetralogy of Fallot[n=4 , truncus arteriosus[n=3 , and double outlet right ventricle with pulmonic stenosis[n=l .Monocuspid homograft patches were used for RVOT widening or REV[reparation l`etage ventriculaire operations in 4 patients. We also used homograft as valved conduits for RVOT reconstruction in 17 patients and left ventricular outflow tract reconstruction in anatomically corrected transposition in 1 patient. Among them size-reducing technique [converting a tricuspid valved conduit into a bicuspid valved conduit were applied to six patients for the correction of size mismatching. The mean follow-up period was 10.6 $\pm$ 5.4 months. There was one operative death[4.5% due to bleeding and one reoperation for removal of vegetation on the homograft leaflet. Postoperative echocardiography documented no significant homograft insufficiency and RVOT obstructions.In short-term, the homograft valves provide excellent hemodynamic characteristics, even though further studies are necessary to evaluate the long-term results.

  • PDF

Successful Correction of Coarctation of the Aorta, the Patent Ductus Arteriosus, and Persistent Left Superior Vena Cava (대동맥축착 동맥관개존 좌공정맥을 합병한 다발성혈관기형의 수술치험예)

  • 김근호
    • Journal of Chest Surgery
    • /
    • 제7권1호
    • /
    • pp.93-100
    • /
    • 1974
  • This is a case report of successful surgical correction of coarctation of the aorta associated with the patent ductus arteriosus and the persistent left superior vena cava. The patient was a 15 year old girl and congenital heart anomaly was suspected at the sixth month after birth. Afterward there has been no embarrassing symptoms until the day of operation except slight dyspnea on exertion, The diagnosis of coarctation of the aorta and the patent ductus arteriesus detected by physical signs and X-ray studies including aortography. In the first place, coarctation of the aorta was corrected with following procedure: partial resections of the aortic wall just above and below the coarctating line of the aorta and removal of diaphragmatic structure of coarctation performed by. cross clamping aorta above and below coarctation, and then the defect of the aortic wall was closed by lateral aortorrhapic suture with atraumatic needle 3-0 silk continuously [Fig. 6]. In the second place, the patent ductus arteriosus was closed with double ligation method. The persistent left superior vena cava left as it has been, because there has been no evidence of hemodynamic abnormal shunt. After operation, excellent result was obtained; blood pressure in the upper and lower extremities was normalized and subjective complains of hypertension in the upper extremity was disappeared.

  • PDF

A Clinical Study on the Development of a Simplified Fat Absorption Test by Simultaneous Administration of $^{125}I$-triolein and Chromic Oxide($^{51}Cr_2O_3$) ($^{125}I-triolein$$^{51}Cr_2O_3$의 동시투여(同時投與)에 의(依)한 지방흡수시험법(脂肪吸收試驗法)의 개발(開發)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Hong, Chang-Gi;Kim, Byung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • 제3권1호
    • /
    • pp.33-39
    • /
    • 1969
  • The conventional triolen absorption test has its defect in that the stool collection was cumbersome, time and energy-wasting. In the present study, the triolen absorption test was carried out using double tracer technique with $^{125}I-triolen\;and\;^{51}Cr_2O_3$ to determine if it can overcome the defect of the conventional method also with satisfactory results. Following were the results: 1. The clinical significance of this double tracer method was essentially the same with that previously done by radioactive. triolen alone. With the fractional fecal samples, the equation, y=0.626x+2.010 was substantiated, hence, this method appears to be clinically valuable if the appropriate correction is applied. With the mixed fecal samples, the equation y=0.642x+1.468 was substantiated (p<0.005) which appears to be also clinically valuable. When these two data were compared, the equation y=0.975x+0.090 (P<0.05) was substantiated, hence, $x{\fallingdotseq}y$. 2. The normal ranges of the fecal triolen excretion rate in this double tracer method were $3.46{\pm}1.69%$, namely, less than 6.9%. 3. The samplings were done from the first to third defecation in cases of clinically normal, and from the first to second defecation in cases of diarrhea or malabsorption. 4. The intestinal malabsorption of triolen was not observed in whom the triolen absorption was supposed to be clinically normal, however. a good number of suspicious malabsorptive cases showed the normal values.

  • PDF

Surgical and Long Term Results for Double Outlet Right Ventricle by the Type of Ventricular Septal Defect (심실중격결손의 형태에 따른 양대혈관 우심실기시증의 수술 및 장기 결과)

  • Yu Song Hyeon;Park Han Ki;Cho Bum Koo;Park Young Hwan
    • Journal of Chest Surgery
    • /
    • 제38권3호
    • /
    • pp.181-190
    • /
    • 2005
  • The results of biventricular repair for double outlet right ventricle have been improved in recent series. We studied the surgical and long term results for total correction of double outlet right ventricle by the type of ventricular septal defect. Material and Method: Between November 1979 and December 2003, 126 patients had biventricular repair for double outlet right ventricle. The mean age was 1.8 years (range 1$\~$44) and 86 patients ($68.3\%$) were male. We classified and studied this disease by the type of VSD. Result: The locations of VSD were subaortic in 79 ($62.7\%$), subpulmonary in 17 ($13.5\%$), doubly committed in 16 ($12.7\%$) and noncommitted in 14 ($11.1\%$). 28 patients had palliative operation before total correction and the mean interval to total correction was 41.0$\pm$45.1 months. The methods of total correction were intraventricular baffling in 37 ($29.4\%$), intraventricular baffling with patch enlargement of right ventricular outflow tract in 49 ($38.9\%$), intraventricular baffling with Rastelli procedure in 15 ($11.9\%$), arterial switch operation in 8 ($6.3\%$) and REV procedure in 4 ($3.2\%$), etc. Hospital mortality rate was $10.3\%$ (13 patients) and 25 reoperations were performed in 24 patients ($19.0\%$). The risk factors for hospital mortality and reoperation were cardiopulmonary bypass time (p=0.020) and previous palliative operation (p=0.013), respectively. Follow up was possible in 98 patients and mean follow up period was 118.9$\pm$70.7 months. The percent survival and survival for freedom from reoperation at 15 years were $82.5\%$ and $66.7\%$, respectively. The survival rate was significantly lower (p=0.003) in transposition of great artery type and remote type than in simple ventricular septal defect type and tetralogy of Fallot type, but there was no statistical differences in survival rate for freedom from reoperation. Conclusion: It is thought to be that acceptible surgical and long term results can be obtained with application of appropriate methods of repair for double outlet right ventricle.

Double-outlet Right Ventricle with Pulmonary Stenosis [DORV: S.D.D.,subaortic VSD with ps]: One Operative case Report (양대혈관 우심실 기시증: 폐동맥협착 동반례의 수술 치험)

  • Kim, Hyeong-Muk;Lee, Nam-Su;Song, Yo-Jun
    • Journal of Chest Surgery
    • /
    • 제10권1호
    • /
    • pp.148-155
    • /
    • 1977
  • The clinical findings with cardioangiography and successful surgical treatment of a 10 year old girl with double-outlet right ventricle is reported at The Dept. of Thoracic and Cardiovascular Surgery, Korea University Hospital, College of Medicine. The patient has been suffered from intermittent cyanosis, palpitation, and exertional dyspnea since 1 year after NFSD, and a holosystolic ejection murmur of grade 4 at the left 3rd intercostal space with mild cyanosis of the lips was the only physical findings at the time of this admission. Cardiac catheterization revealed ventricular septal defect with left to right shunt of 43% and right to left shunt of 10.2%. On cardioangiography from the left ventricle revealed all of the left ventricular outflow shunted into the right ventricle through the large ventricular septal defect, and the aorta originated from the infundibular chamber of the right ventricle with left, anterior sided pulmonary artery. The atria, viscera, and ventricles were normally located, and right ventricular out-flow was narrowed with infundibular hypertrophy and pulmonary valvular stenosis. Surgical correction was accomplished by closure of the ventricular septal defect in such a way that left ventricular outflow was routed via a Teflon felt prosthetic tunnel to the aorta, and pulmonary valvulotomy with infundibulectomy Was done to pass Hegar`s dilator No. 15 for reconstruction of the right ventricular outflow tract. The patient tolerated complete repair and has continued to improve over a period of three months after operation with normal school life. Details of the disease and method of repair are presented with related references.

  • PDF

Follow-Up of Residual Shunt after Repair of Ventricular Septal Defect (심실중격결손 봉합 후 잔류 단락의 추적관찰)

  • 정태은;이장훈;김도형;백종현;이동협;이정철;한승세;이영환
    • Journal of Chest Surgery
    • /
    • 제35권8호
    • /
    • pp.580-583
    • /
    • 2002
  • Background: Obtaining precise hemodynamic and morphological information in the early postoperative period after surgical correction of congenital heart disease is important in determining the need for future medical or surgical intervention. We investigated the residual shunting after surgical repair of simple ventricular septal defect in order to know the incidence of residual shunting in the postoperative period and the natural history of small residual shunts located in the peripatch area. Material and Method: Forty three consecutive patients under one year of age who underwent patch repair of a simple ventricular septal defect were evaluated for incidence of residual shunts by echocardiography. Result: Eleven patients had echocardiographic residual shunt in the peripatch area at immediate postoperative period, however, there were no patients who needed reoperation due to deteriorated hemodynamic effect of residual shunt. The incidence of residual shunts was not significantly different with type of ventricular septal defect and material used for closure. During follow up period, two patients were lost and remaining nine patients no longer showed evidence of residual shunt. The mean time of last evidence of shunt was $4.2{\pm}3.6$ months after operation. Conclusion: Residual peripatch shunt flow was frequently noted in the immediate postoperative period following surgical repair of ventricular septal defect, however, most of them were disappeared within six months.

Web Uni-Limb Z-Plasty for Correction of Alar Web Deformity in Unilateral Cleft Lip Nasal Deformities: Photogrammetric Analysis (일측구순열비변형에서 물갈퀴일측지Z성형술을 이용한 외비공과 비주의 재건: 사진계측학적 연구)

  • Han, Ki-Hwan;Kim, Dae-Jin;Park, Mu-Shik;Kim, Jun-Hyung;Son, Dae-Gu
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.740-746
    • /
    • 2011
  • Purpose: In the treatment of the unilateral cleft lip nasal deformities, the correction of the low-nostril height and short-columella are very difficult problems. We report the treatment outcomes of web uni-limb Z-plasty used for correction of unilateral cleft lip nasal deformities by using photographic analysis. Methods: A total of 36 patients with unilateral cleft lip nasal deformities were enrolled in this study, who underwent web uni-limb Z-plasty and were followed up for at least 6 months. First, a triangular flap was made on the medial side of alar-columella web. The nostril apex of cleft side was corrected to a higher point compared to noncleft side by 2 mm. The flap was transposed into the defect of the vestibule. To reduce the bulging of the flap, horizontal cinching sutures were added. Postoperative outcomes were evaluated by using photographic analysis. 2 indices and 1 angle were measured on their photographs taken before and after the surgery. Symmetry was also evaluated by means of the noncleft side to cleft side index. For anthropologic assessment, observers described postoperative outcomes, using Ordinary Scale Method. Results: The postoperative values obtained in photographic analysis improved compared to preoperative ones. More improving anthropologic assessment was shown in post-than pre-operative. Conclusion: Although, further long term follow up is needed, we found this technique to be an effective procedure to the symmetry of nostril apex level and the lengthening of columella in the unilateral cleft lip nasal deformities.

Evaluation of Image Quality Change by Truncated Region in Brain PET/CT (Brain PET에서 Truncated Region에 의한 영상의 질 평가)

  • Lee, Hong-Jae;Do, Yong-Ho;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제19권2호
    • /
    • pp.68-73
    • /
    • 2015
  • Purpose The purpose of this study was to evaluate image quality change by truncated region in field of view (FOV) of attenuation correction computed tomography (AC-CT) in brain PET/CT. Materials and Methods Biograph Truepoint 40 with TrueV (Siemens) was used as a scanner. $^{68}Ge$ phantom scan was performed with and without applying brain holder using brain PET/CT protocol. PET attenuation correction factor (ACF) was evaluated according to existence of pallet in FOV of AC-CT. FBP, OSEM-3D and PSF methods were applied for PET reconstruction. Parameters of iteration 4, subsets 21 and gaussian 2 mm filter were applied for iterative reconstruction methods. Window level 2900, width 6000 and level 4, 200, width 1000 were set for visual evaluation of PET AC images. Vertical profiles of 5 slices and 20 slices summation images applied gaussian 5 mm filter were produced for evaluating integral uniformity. Results Patient pallet was not covered in FOV of AC-CT when without applying brain holder because of small size of FOV. It resulted in defect of ACF sinogram by truncated region in ACF evaluation. When without applying brain holder, defect was appeared in lower part of transverse image on condition of window level 4200, width 1000 in PET AC image evaluation. With and without applying brain holder, integral uniformities of 5 slices and 20 slices summation images were 7.2%, 6.7% and 11.7%, 6.7%. Conclusion Truncated region by small FOV results in count defect in occipital lobe of brain in clinical or research studies. It is necessary to understand effect of truncated region and apply appropriate accessory for brain PET/CT.

  • PDF

Correction method for the Variation of the Image Plane Generated by Various Symmetric Error Factors of Zoom Lenses of Digital Still Cameras and Estimation of Defect Rate Due to the Correction (디지털 카메라용 줌렌즈에서 대칭성 오차요인에 의한 상면 변화의 보정과 이에 따른 불량률 예측)

  • Ryu, Jae-Myung;Kang, Geon-Mo;Lee, Hae-Jin;Lee, Hyuck-Ki;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • 제17권5호
    • /
    • pp.420-429
    • /
    • 2006
  • In the zoom lens of digital still cameras with the variation of the image plane generated by various symmetric error factors such as curvature, thickness and refractive index error of each lens surface about the optic axis, we induce a theoretical condition to fix constantly the image plane by translating the compensator group of the zoom lens by using the Gaussian bracket. We confirm the validity of this condition by using three examples of general zoom lens types with 3, 4, and 5 groups, respectively. When these error factors are randomly changed within the range of tolerance according to the Monte Carlo method, we verify that the distributions of the degree of moving of the compensator are normal distributions at three zoom lens types. From capability analysis using these results, we theoretically propose the method estimating the standard deviation, that is, sigma-level, as a function of the maximum movement of the compensator.

Repair of intracardiac defect under simple deep hypothermia in infancy without cardiopulmonary bypass: report of 3 cases (단순 초저온법에 의한 개심술: 3례 보)

  • 조범구
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.189-196
    • /
    • 1984
  • Although the conventional methods of cardiopulmonary bypass for open heart surgery have been employed, it has been usual method to repair of congenital heart disease in infancy using deep hypother-mia and circulatory arrest technique. In 1980, we reported total correction of congenital heart disease using surface induced hypothermia-total circulatory arrest and rewarming with limited cardiopulmonary bypass. in 1981, three patients below 10 kilogram, who had ASD and PDA, and two of VSD with pulmonary hypertension were operated on using simple deep hypothermia without cardiopulmonary bypass. During surface cooling, there were no ventricular fibrillation and arrhythmia. There were no difficulties to resuscitate the heart. Postoperative respiratory and neurologic complication were not occurred. Follow up examination for two to three years gave no evidence of cerebral damage due to circulatory arrest.

  • PDF