• Title/Summary/Keyword: defect type

Search Result 1,068, Processing Time 0.031 seconds

Ventricular Septal Defect with Aortic Insufficiency: A Report of 7 Cases (대동맥판막 폐쇄부전증을 동반한 심실중격결손증 -7례 보고-)

  • 조대윤
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.50-55
    • /
    • 1979
  • The development of aortic insufficiency radically alters the physical findings which are generally associated with ventricular septal defect that was not hemodynamically significant, and the combination of the two lesions produces a typical clinical picture, that may be serious and life-threatening when it is left untreated. Therefore, the selection of patients, type and timing of surgical treatment is considered to be important. Among 114 cases of ventricular septal defect treated surgically utilizing cardiopulmonary bypass in the Department of Thoracic Surgery, Seoul National University Hospital, 7 cases were associated with aortic insufficiency. 1. Five cases were male, and 2 cases were female. Ages were from 4 years to 24 years, and mean age was 11.9 years. 2. In all cases, ventricular septal defect was closed with Teflon patch. In a case, a aortic valvuloplasty and in another, a aortic valve replacement with Hancock valve 23 mm., 5 months after the closure of ventricular septal defect were done. 3. Four cases were type I ventricular septal defect by Kirklin`s classification, 3 cases were type II ventricular septal defect, and diameters of ventricular septal defect were from 3.5 cm. to 0.7 cm. A PDA. was combined to a type I ventricular septal defect. 4. In 5 cases, herniation of the aortic cusp through the ventricular septal defect and in a case, annulus dilatation on the aortic valve was noted. 5. Two cases with type I ventricular septal defect and severe pulmonary hypertension expired. A re-opened case with type II ventricular septal defect expired. 6. Four cases were alive, and all of them show decrease of pulse pressure and aortic insufficiency.

  • PDF

Case Study on Landscape Defect Type of Defect Lawsuit in Apartment Building (공동주택 하자소송에서의 조경하자유형 사례분석)

  • Park, Jun-Mo;Seo, Deok-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.263-264
    • /
    • 2016
  • Since 2000s in Korea, apartment building tended to become goods or assets rather than houses. Therefore, conflicts between supplier and consumer were aggravated, and the defect dispute has been increased rapidly. This dispute enlarges to defect lawsuit and it is social and economical matter. The landscape work in apartment building is main work for a resident that appearance and convenient facility which lawn, tree, fountain, chair, playground, and etc. A number of defects surround landscape work are important issue in defect lawsuit, but, a related research is a minority, and a regulation is incomplete. Therefore, this study is basic study for standard of landscape defect type. As case study on defect lawsuit, draw a landscape defect type in apartment building.

  • PDF

Defect Type Prediction Method in Manufacturing Process Using Data Mining Technique (데이터마이닝 기법을 이용한 제조 공정내의 불량항목별 예측방법)

  • Byeon Sung-Kyu;Kang Chang-Wook;Sim Seong-Bo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.2
    • /
    • pp.10-16
    • /
    • 2004
  • Data mining technique is the exploration and analysis, by automatic or semiautomatic means, of large quantities of data in order to discover meaningful patterns and rules. This paper uses a data mining technique for the prediction of defect types in manufacturing Process. The Purpose of this Paper is to model the recognition of defect type Patterns and Prediction of each defect type before it occurs in manufacturing process. The proposed model consists of data handling, defect type analysis, and defect type prediction stages. The performance measurement shows that it is higher in prediction accuracy than logistic regression model.

Clinical Evaluation of 70 Cases of Ventricular Septal Defect in Korea (심실 중격결손증에 대한 임상적 고찰 [70예])

  • 조규석
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 1978
  • Ventricular septal defect was the most common congenital Heart disease admitted to the Severance Hospital from December, 1963 to June 30. 1977. A total of 1,811 cardiac patients received cardiac catheterization in the CardiacCenter of Yonsei University Medical College. Out of the 1,811 cardiac patients, 791 cases had congenital heart disease and of these 172 cases had ventricular septal defect. This amounted to 21.7% of all those with congenital heart disease. Seventy cases of ventricular septal defect operated on in the chest surgery department are presented. Of these 70 cases of ventricular septal defect, 54 cases were male and 16 cases were female. Their ages ranged from 4/12 months to 32 years. The ratio of systolic pressure of the main pulmonary to systemic artery [Pp/Ps] for 29 of the 59 isolated ventricular septal defects was below 45 percent. Pp/Ps ratio for 19 of the 59 isolated ventricular septal defects was 75 percent. The patients were mostly below fifteen years of age. Out of 64 cases, there were 36 cases of type II defects, 20 cases of type I, 4 cases of type III , 2 cases of type IV, one case of both type II and one case of left ventricular right atrial communication. The anomalies associated with ventricular septal defect were 13 in all; 4 cases of aortic insufficiency, 3 cases of ruptured aneurysm of the sortie sinus of valsalva, 2 cases of ruptured aneurysm of the sortie sinus of valsalva with aortic insufficiency, 2 cases of patent ductus arteriosus, one case of ruptured aneurysm of the aortic sinus of valsalva with atrial septal defect [secundum type] and one case of atrial septal defect [secundum type]. Overall mortality was 8.6 percent. The mortality in pulmonary artery banding was 37.5 percent. The causes of mortality were in one case congestive heart failure, in one case asphyxia and in one case respiratory insufficiency. Tile mortality in ventricular septal defect associated with pulmonary hypertension was 7.1 percent. The cause of mortality was in one case low cardiac output syndrome. There was no mortality in the ventricular septal defects without pulmonary hypertension and mortality in the ventricular septal defect. In ventricular septal defect associated with combined anomalies, the causes mortality were in one case respiratory insufficiency and in one case congestive heart failure.

  • PDF

Type Classification and Shape Display of Brazing Defect in Heat Exchanger (열교환기 브레이징 결함의 유형 분류 및 형상 디스플레이)

  • Kim, Jin-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2013
  • X-ray cross-sectional image-based inspection technique is one of the most useful methods to inspect the brazing joints of heat exchanger. Through X-ray cross-sectional image acquisition, image processing, and defect inspection, the defects of brazing joints can be detected. This paper presents a method to judge the type of detected defects automatically, and to display them three-dimensionally. The defect type is classified as unconnected defect, void, and so on, based on location, size, and shape information of defect. Three-dimensional display which is realized using OpenGL (Open Graphics Library) will be helpful to understand the overall situation including location, size, shape of the defects in a test object.

A study on Improvement Method for Systematic Defect Management of Apartment Life-cycle (공동주택 생애주기의 체계적인 하자관리를 위한 개선 방안 연구)

  • Park, Chang-Wook;Yun, Seok-Heon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.618-621
    • /
    • 2007
  • The existing defect management is focused on step before closing work, a builder preliminary research and tenant preliminary research. Each step is not related. And the existing study on defect management mainly classify into work type and defect type according to work type. This study divide into defect part. Also this study propose PDA based web and 3DCAD for improving method of existing defect management.

  • PDF

Aortopulmonary septal defect with anomalous origin of the RPA from aorta and PDA (개방성 동맥관과 우폐동맥 이상기시를 동반한 대동맥 폐동맥 중격결손증 1례 보)

  • 남구현
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.398-401
    • /
    • 1984
  • Aortopulmonary septal defect is rare congenital heart disease. An 8-year-old girl was diagnosed as a ventricular septal defect with patent ductus arteriosus at Department of Thoracic and Cardiovascular Surgery of Chungnam National University Hospital. On operation, the defect was confirmed as an aortopulmonary septal defect [Type I], anomalous origin of right pulmonary artery from aorta [Type Ill] and patent ductus arteriosus. The defect was repaired anatomically with cardiopulmonary bypass. But she was not survived because of uncontrollable bleeding from aorta.

  • PDF

Surgical Treatment of Atrial Septal Defect: Secundum Type (심방중격결손증의 외과적 요법)

  • 안광필;이영균
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.81-88
    • /
    • 1975
  • Up to October 31, 1975, 34 cases of atrial septal defect, secundum type, operated in this department, were presented. This is 23.2% of all congenital heart diseases, operated utilizing cardiopulmonary bypass, in this department during this period [34 out of 146]. Out of 34 cases, 32 cases are pure ostium secundum type and one case is sinus venosus and another one is ostium secundum type with partial anomalous pulmonary venous drainage. Six cases of endocardial cushion defect and 3 cases of trilogy of Fallot are excluded in this report. All 34 cases are repaired under direct vision utilizing extracorporeal circulation. Among 34 cases of atrial septal defect, 16 cases are male, and 18 cases are female. Their ages range between 3 to 48 years, but over 59% of the cases are below the ages of 20 years. Thirty-two cases are repaired by direct sutures while 2 cases are repaired with Teflon patches. The average perfusion time is 30 minutes; the shortest 12 and the longest 81 minutes. The number of the defect is single in 31 cases, double in 2 cases, triple in one case. But the associated defect except the main defect are so small as can be closed by simple direct suture. The size of the defect is average $12cm^2$; the smallest 0.7 and the largest $25cm^2$. The surgical mortality is 2 cases [5.6%] and other cases are found to be excellent in the follow up studies.

  • PDF

Deterministic Estimation of Stripe Type Defects and Reconstruction of Mask Pattern in L/S Type Mask Inspection

  • Kim, Wooshik;Park, Min-Chul
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.619-628
    • /
    • 2015
  • In this paper, we consider a method for estimating a stripe-type defect and the reconstruction of a defect-free L/S type mask used in lithography. Comparing diffraction patterns of defected and defect-free masks, we derive equations for the estimation of the location and size of the defect. We construct an analytical model for this problem and derive closed form equations to determine the location and size using phase retrieval problem solving techniques. Consequently, we develop an algorithm that determines a defect-free mask pattern. An example shows the validity of the equations.

Impact Analysis of Construction Delay: The Case of Defects In the Top-down Construction Method

  • Suk, Janghwan;Kwon, Woobin;Soe, Jang-woo;Cho, Hunhee
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.213-221
    • /
    • 2022
  • Defects are the risk factors in the construction process of buildings. They cause damage, delaying the construction duration. They especially cause adverse effects on the top-down construction method. This study analyzed the degree of construction delay induced by each work type, focusing on defects in the top-down method. Then, we derived construction delay induction coefficient from different work types in order by using the severity of construction delay per defect and the occurrence probability of defect; this assessment model measures the impact of defects on construction delay for each work type. Furthermore, by comparing each work type based on the defect frequency and the construction delay induction coefficient, we found work types that need to be administered attentively. We identified that plastering work was easy to overlook, requiring caution in defect management. This study provides an efficient defect management system suitable for the buildings that are built using the top-down construction method.

  • PDF