• 제목/요약/키워드: defect morphology

검색결과 113건 처리시간 0.025초

말초신경 결손시 신경도관으로서 Gore-Tex® 도관의 유용성 (The Availability of Gore-Tex® Tube as Nerve Conduit at the Peripheral Nerve Defect)

  • 이기호;오상하;이승렬;강낙헌
    • Archives of Plastic Surgery
    • /
    • 제32권5호
    • /
    • pp.613-618
    • /
    • 2005
  • When a large peripheral nerve defect occurs, an autologous nerve graft is the most ideal method of recinstruction. But an autologous nerve graft has many limitations due to donor site morbidities. Many previous focused on finding the ideal nerve conduit. Among them, $Gore-Tex^{(R)}$ has several advantages over other conduits. It can be manipulated to a suitable size, does not collapse easily, and it is a semi- permeable material that contain pores. A round shaped nerve can be newly formed because of its smooth inner surface. The purpose of this study was to evaluate the availability of $Gore-Tex^{(R)}$ tube as a nerve conduit at the peripheral nerve defect in the rat sciatic nerve. The 10 mm nerve gap was made in each group. A $Gore-Tex^{(R)}$ tube filled with skeletal muscle was inserted and autologous nerve graft was harvested, respectively. In the experimental group, we placed a 0.5 mm thickness, $30{\mu}m$ pored, 1.8 mm in diameter and 14 mm length tube with skeletal muscle inserted inside. In the control group, the nerve gap was inserted with a rat sciatic nerve. We estimated the results electrophysiologically and histologically to 16 weeks postoperatively. Results in the nerve conduction velocity, total myelinated axon count, myelin sheath thickness and mean nerve fiber diameter, the experimental group was substantially lower than that of the control group, but the statistic difference was not significant (p<0.05). The morphology was very similar in both groups, microscopically. From the above results, We conclude that $Gore-Tex^{(R)}$ qualifies as an ideal nerve conduit. It is suggested that $Gore-Tex^{(R)}$ tube filled with skeletal muscle may, substitute for an autologous nerve graft.

기계적 가공과 무전해 선택적 증착기술을 이용한 나노/마이크로 금속패턴 제작에 관한 연구 (A Study on Nano/Micro Pattern Fabrication of Metals by Using Mechanical Machining and Selective Deposition Technique)

  • 조상현;윤성원;강충길
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.171-177
    • /
    • 2006
  • This study was performed as a part of the research on the development of a maskless and electroless process for fabricating metal micro/nanostructures by using a nanoindenter and an electroless deposition technique. $2-{\mu}m$-deep indentation tests on Ni and Cu samples were performed. The elastic recovery of the Ni and Cu was 9.30% and 9.53% of the maximum penetration depth, respectively. The hardness and the elastic modulus were 1.56 GPa and 120 GPa for Ni and 1.51 GPa and 104 GPa for Cu. The effect of single-point diamond machining conditions such as the Berkovich tip orientation (0, 45, and $90^{\circ}$ ) and the normal load (0.1, 0.3, 0.5, 1, 3, and 5 mN), on both the deformation behavior and the morphology of cutting traces (such as width and depth) was investigated by constant-load scratch tests. The tip orientation had a significant influence on the coefficient of friction, which varied from 0.52-0.66 for Ni and from 0.46- 0.61 for Cu. The crisscross-pattern sample showed that the tip orientation strongly affects the surface quality of the machined are a during scratching. A selective deposition of Cu at the pit-like defect on a p-type Si(111) surface was also investigated. Preferential deposition of the Cu occurred at the surface defect sites of silicon wafers, indicating that those defect sites act as active sites for the deposition reaction. The shape of the Cu-deposited area was almost the same as that of the residual stress field.

성인에 있어서 심방중격결손증 교정수술후 심전도의 경시적 변화에 관한 연구 (A follow-up study of electrocardiographic changes following the corrective surgery for atrial septal defect in adult)

  • 이영탁;채헌;서경필
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.241-250
    • /
    • 1987
  • We scrutinized the preoperative electrocardiographic and hemodynamic findings in adult atrial septal defects older than 15 years, and then followed up the postoperative electrocardiographic changes sequentially. In preoperative electrocardiographs, the mean PR interval [0.17 sec] was prolonged than normal adults [M;0.13,F;0.15], and the mean QRS axis [93.1*] was deviated to rightward than normal [M;63.7*,F;64.4*], and 122 cases of all 159 patients [77.8%] were in RAD quadrant. The QRS morphology was classified into three groups; a] crista supraventricularis hypertrophy, 25 cases, b] right ventricular outflow tract hypertrophy, 89 cases, c] right ventricular hypertrophy, 44 cases, and normal rs pattern, 1 case. Comparing the QP/QS, Pp/Ps, Rp/Rs in these three groups, Qp/Qs increased a] 2.65 to b] 2.97 and decreased b] 2.97 to c] 2.55, Pp/Ps increased a] 0.27 to b] 0.35 to c] 0.44, and Rp/Rs increased a] 0.1 to b] 0.14 to c] 0.2. In comparing the atrial fibrillation with sinus rhythm, the patient`s mean age was increased [26.4 to 45.7], the mean Qp/Qs was decreased [2.97 to 2.7], the mean Pp/Ps was increased [0.35 to 0.46], the mean Rp/Rs increased [0.14 to 0.2], and the QRS morphology was RVOT hypertrophy;7 cases, RVH;2 cases in all 11 cases. Therefore, the atrial fibrillation was appeared in progressed status. Increasing the mean pulmonary arterial pressure, size of the R` wave in Vl lead increased, and the QRS morphology tended to become severe patterns. Postoperatively, the PR interval shortened and QRS axis tended to normal axis quadrant, and size of R` wave decreased sequentially, atrial fibrillation disappeared in 4 cases. Conclusively, by use of the conventional surface electrocardiography, we could anticipate the hemodynamic changes and the prognosis at outpatient department.

  • PDF

급성 우심 부전의 집중 치료 (Intensive management of acute right heart failure)

  • 김기범;노정일
    • Clinical and Experimental Pediatrics
    • /
    • 제50권11호
    • /
    • pp.1041-1048
    • /
    • 2007
  • Not a few patients in children and adolescents are suffering from right ventricular (RV) dysfunction resulting from various conditions such as chronic lung disease, left ventricular dysfunction, pulmonary hypertension, or congenital heart defect. The RV is different from the left ventricle in terms of ventricular morphology, myocardial contractile pattern and special vulnerability to the pressure overload. Right ventricular failure (RVF) can be evaluated in terms of decreased RV contractility, RV volume overload, and/or RV pressure overload. The management for RVF starts from clear understanding of the pathophysiology of RVF. In addition to correction of the underlying disease, management of RVF per se is very important. Meticulous control of volume status, inotropic agents, vasopressors, and pulmonary selective vasodilators are the main tools in the management of RVF. The relative importance of each tool depends on the individual clinical status. Medical assist device and surgery can be considered selectively in case of refractory RVF to optimal medical treatment.

Effect of ultra - violet laser treatment on multi - wall carbon nanotube surface

  • Kim, Jun-Sik;Ahn, Kyoung-Soo;Lee, Chang-Hyo;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.689-691
    • /
    • 2002
  • Well-aligned multi-wall carbon nanotubes (MWCNTs) have been grown on both Coming glass and silicon substrates at about 400 $^{\circ}C$ by a modified plasma - enhanced chemical vapor deposition system. We have investigated laser irradiation effect on carbon nanotube surface by using an ultra - violet laser. The laser operated to modify structural defect of was carbon nanotube and to ablate possible contamination of carbon nanotube surface. The morphology and surface transformation of MWCNTs as analyzed by a SEM. In addition, the field emission measurement was also carried out in a vacuum chamber with a $10^{-7}$ Torr base pressure by applying bias voltages up to 1000V.

  • PDF

New Retention System Using Branched Polymer

  • Son, Dong-Jin;Kim, Bong-Yong
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.251-256
    • /
    • 2006
  • The purpose of this study was to confirm multiple retention system of C-PAM, A-PAM and Inorganic micro particles vs. traditional micro particle system and dual polymer system by measuring retention, drainage and formation using RDA HSF and Techpap 2D -F Sensor The benefits of dual polymer system were easy to use, low chemical consumption and good retention property but defect was worse drainage property than inorganic microparticle systems. On the other hand, Inorganic microparticle system had benefit of good drainage effect but defects were difficult to use, high chemical consumption. Therefore, we tried to find optimal morphology of polyacrylamide and applied to multiple retention system of C-PAM, A-PAM and inorganic microparticles to compensate defects of both of retention systems. As a result, we found the performance of branched C-PAM, branched A-PAM and inorganic micro particle triple system was more appropriate than traditional inorganic mircoparticle systems or dual polymer systems by comparing retention, drainage and formation.

  • PDF

A Review of Wet Chemical Etching of Glasses in Hydrofluoric Acid based Solution for Thin Film Silicon Solar Cell Application

  • Park, Hyeongsik;Cho, Jae Hyun;Jung, Jun Hee;Duy, Pham Phong;Le, Anh Huy Tuan;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제5권3호
    • /
    • pp.75-82
    • /
    • 2017
  • High efficiency thin film solar cells require an absorber layer with high absorption and low defect, a transparent conductive oxide (TCO) film with high transmittance of over 80% and a high conductivity. Furthermore, light can be captured through the glass substrate and sent to the light absorbing layer to improve the efficiency. In this paper, morphology formation on the surface of glass substrate was investigated by using HF, mainly classified as random etching and periodic etching. We discussed about the etch mechanism, etch rate and hard mask materials, and periodic light trapping structure.

Comparative study on structural and luminescence properties of solution processed ZnO thin films

  • Park, Byung-Yoon;Choi, Sung-Ho;Hong, Chang-Seop;Ryu, Beyong-Hwan;Jung, Ha-Kyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1433-1436
    • /
    • 2009
  • Film morphology, crystallinity, and luminescence property of solution processed ZnO films have been studied. Fluorine addition and annealing ambient significantly change the defect-related emission band as well as the structural property. Using the overall emission behaviors, we can predict an optimized process condition for solution-based ZnO thin film.

  • PDF

MDF 시멘트-SiC 위스커 복합재료의 미세구조적 특성 (Microstructural Characterization of MDF Cement-SiC Whisker Composites)

  • 김태현;최상흘
    • 한국세라믹학회지
    • /
    • 제29권8호
    • /
    • pp.617-622
    • /
    • 1992
  • In order to study on the effect of SiC whisker in flexural strength characterization of macro defect-free (MDF) cement composites, which composed of high alumina cement and polyvinyl alcohol, microstructural characterization of the composite specimens fabricated by the addition of SiC whiskers was investigated. Microproes are created around the SiC whisker, MDF cement didn't react with the SiC whisker. However, flexural strength of the composites have been improved. Fracture morphology of the composites, presents mainly intergranular type fracture passing around the unhydrated particles and siC whiskers, and partially transgranular type fracture. The main strengthening mechanisms of the MDF cement composites reinforced with SiC whiskers are characterized by crack deflection, microcracking, and bridging of cracks.

  • PDF

LPCVD에 의한 다결정 3C-SiC 결정성장에 관한 연구 (Study for polycrystalline 3C-SiC thin films growth by LPCVD)

  • 김강산;정귀상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1313-1314
    • /
    • 2006
  • The polycrystalline 3C-SiC thin films heteroepitaxially grown by LPCVD method using single precursor 1,3-disilabutane at $850^{\circ}C$. The crystallinity of the 3C-SiC thin film was analyzed by XRD and FT-IR. Residual strain was investigated by Raman scattering. The surface morphology was also observed by AFM and voids or dislocations between SiC and $SiO_2$ were measured by SEM. The grown poly 3C-SiC thin film is very good crystalline quality, surface like mirror, and low defect and strain. Therefore, the polycrystalline 3C-SiC is suitable for harsh environment MEMS applications.

  • PDF