• Title/Summary/Keyword: deep inferior

Search Result 115, Processing Time 0.028 seconds

The Occurence of Deep Vein Thrombosis in Abdominal Compartment Patient (복부구획증후군 환자에서 발생한 심부정맥혈전증)

  • Kim, Seong Yup;Jin, Sung Chan
    • Journal of Trauma and Injury
    • /
    • v.26 no.4
    • /
    • pp.312-315
    • /
    • 2013
  • Abdominal compartment syndrome is one cause of deep vein thrombosis of lower extremity. Although prophylactic dose of anticoagulation agent is safely started after 24~48 hours without the evidence of active bleeding, there may be bleeding complication related to invasive procedure which trauma victims undergo. Inferior vena cava filter should be considered in the treatment plan of this complex situation.

Atypical Patterns of Deep Inferior Epigastric Artery: Clinical Implication of Preoperative CT Angiography (비전형적인 심하복벽동맥의 주행을 파악하기 위한 수술 전 CT Angiography의 유용성)

  • Lee, Taek-Jong;Kim, Sung-Chan;Eom, Jin-Sup;Kim, Eun-Key
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Purpose: Purpose: The free deep inferior epigastric artery perforator (DIEP) flap is a popular option for autologous breast reconstruction. However, the anatomy of the deep inferior epigastric artery(DIEA) may vary from one individual to another. Unexpected vascular anomaly can confuse the surgeon and affects on the safety of the free DIEP flap. Materials and Methods: Thirty five consecutive patients who underwent free DIEP/TRAM flap for immediate breast reconstruction between Mar. 2010 and Oct. 2010 were enrolled in this study. Computed tomography angiography (CT angiography) of abdomen was evaluated part of our standard preoperative assessment: atypical patterns of DIEA/DIEP were evaluated by preoperative CT angiography and compared with intraoperative finding. Results: Atypical patterns of DIEA/DIEP which may affect preoperative planning were noted as the following: Circummusclar/subfascial DIEA (n=1), DIEA running underneath rectus muscle (n=8), septocutaneous perforator (n=3), peritoneo-cutaneous perforator (n=1), a large branch going into peritoneum (n=1), and very early division and muscle penetration of DIEA (n=1). Conclusion: Atypical DIEA/DIEP that might change the operation plan is not rare, so the individualized planning based on the preoperative CT angiography is recommended. Preoperative CT angiography could help to select reliable and easy-to-dissect perforator in free DIEP/TRAM breast reconstruction.

  • PDF

Comparison of the second and third intercostal spaces regarding the use of internal mammary vessels as recipient vessels in DIEP flap breast reconstruction: An anatomical and clinical study

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.333-339
    • /
    • 2020
  • Background The purpose of this study was to compare the anatomical features of the internal mammary vessels (IMVs) at the second and third intercostal spaces (ICSs) with regard to their use as recipient vessels in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods A total of 38 consecutive DIEP breast reconstructions in 36 patients were performed using IMVs as recipient vessels between March 2017 and August 2018. The intraoperative findings and postoperative complications were analyzed. Anatomical analyses were performed using intraoperative measurements and computed tomography (CT) angiographic images. Results CT angiographic analysis revealed the mean diameter of the deep inferior epigastric artery to be 2.42±0.27 mm, while that of the deep inferior epigastric vein was 2.91±0.30 mm. A larger mean vessel diameter was observed at the second than at the third ICS for both the internal mammary artery (2.26±0.32 mm vs. 1.99±0.33 mm, respectively; P=0.001) and the internal mammary vein (IMv) (2.52±0.46 mm vs. 2.05±0.42 mm, respectively; P<0.001). Similarly, the second ICS was wider than the third (18.08±3.72 mm vs. 12.32±2.96 mm, respectively; P<0.001) and the distance from the medial sternal border to the medial IMv was greater (9.49±2.28 mm vs. 7.18±2.13 mm, respectively; P<0.001). Bifurcations of the IMv were found in 18.4% of cases at the second ICS and in 63.2% of cases at the third ICS. Conclusions The IMVs at the second ICS had more favorable anatomic features for use as recipient vessels in DIEP flap breast reconstruction than those at the third ICS.

Topography of Deep Inferior Epigastric Perforator Flap (심부하복벽천공지의 국소해부학적 고찰)

  • Kim, Chang-Yeon;Oh, Jung-Keun;Hwang, Weon-Jung;Kim, Jeong-Tae;Ahn, Hee-Chang
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.2
    • /
    • pp.141-145
    • /
    • 2002
  • Rectus abdominis muscle free flap is widely used for breast reconstruction and soft tissue defect in lower leg but donor-site morbidities such as abdominal wall weakness, hernia, bulging are troublesome. Recently, to minimize donor-site morbidity, there has been a surge in interest in deep inferior epigastric perforator(DIEP) free flap preserving the anatomy of rectus abdominis muscle, fascia, and motor nerve. Between August of 1995 and September of 2002, topographic investigation of DIEP was performed during the elevation of 97 cases of TRAM free flap and 5 cases of DIEP free flap. There were 84 cases of breast reconstructions, 12 cases of lower leg reconstructions, and 6 cases of head and neck reconstruction. We could observe total 10 to 12 perforators on each rectus abdominis muscle below umbilicus. Among these, the numbers of large perforators(>1.5mm of diameter) were mean 2.1 in lateral half of rectus abdominis muscle, mean 1.2 in medial half, and mean 0.5 in linea alba and paramedian. DIEP free flap provides ample amount of well vascularized soft tissue without inclusion of any rectus abdominis muscle and fascia and minimizes donor-site morbidity. One perforator with significant flow can perfuse the whole flap. For large flap, a perforator of the medial row provides better perfusion to zone-4 than one of lateral row and, if diameter of perforator is small, $2{\sim}3$ perforators can be used. According to the condition of recipient-site, thin flap can be harvested. As DIEP free flap has many advantage, perforator topography will be useful in increasing clinical usage of DIEP free flap.

  • PDF

Surgical Considerations of One-Stage Reconstruction of Large Extremity Defects Using a Thin Deep Inferior Epigastric Perforator Flap

  • Seung Yeol Lee;Moon Chul Seok;Bo Young Park
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.586-592
    • /
    • 2023
  • Background One-stage reconstruction with "thin perforator flaps" has been attempted to salvage limbs and restore function. The deep inferior epigastric perforator (DIEP) flap is a commonly utilized flap in breast reconstruction (BR). The purpose of this study is to present the versatility of DIEP flaps for the reconstruction of large defects of the extremities. Methods Patients with large tissue defects on extremities who were treated with thin DIEP flaps from January 2016 to January 2018 were included. They were minimally followed up for 36 months. We analyzed the etiology and location of the soft tissue defect, flap design, anastomosis type, outcome, and complications. We also considered the technical differences in the DIEP flap between breast and extremity reconstruction. Results Overall, six free DIEP flaps were included in the study. The flap size ranged from 15 × 12 to 30 × 16 cm2. All flaps were transversely designed similar to a traditional BR design. Three flaps were elevated with two perforators. Primary closure of the donor site was possible in all cases. Five flaps survived with no complications. However, partial necrosis occurred in one flap. Conclusion A DIEP flap is not the first choice for soft tissue defects, but it should be considered for one-stage reconstruction of large defects when the circulation zone of the DIEP flap is considered. In addition, this flap has many advantages over other flaps such as provision of the largest skin paddle, low donor site morbidity with a concealed scar, versatile supercharging technique, and a long pedicle.

Orienting the superficial inferior epigastric artery (SIEA) pedicle in a stacked SIEA-deep inferior epigastric perforator free flap configuration for unilateral tertiary breast reconstruction

  • Yu, Ya-han;Ghorra, Dina;Bojanic, Christine;Aria, Oti N.;MacLennan, Louise;Malata, Charles M.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.473-477
    • /
    • 2020
  • Superficial inferior epigastric artery (SIEA) flaps represent a useful option in autologous breast reconstruction. However, the short-fixed pedicle can limit flap inset options. We present a challenging flap inset successfully addressed by de-epithelialization, turnover, and counterintuitive rotation. A 47-year-old woman underwent left tertiary breast reconstruction with stacked free flaps using right deep inferior epigastric perforator and left SIEA vessels. Antegrade and retrograde anastomoses to the internal mammary (IM) vessels were preferred; additionally, the thoracodorsal vessels were unavailable due to previous latissimus dorsi breast reconstruction. Optimal shaping required repositioning of the lateral ends of the flaps superiorly, which would position the ipsilateral SIEA hemi-flap pedicle lateral to and out of reach of the IM vessels. This problem was overcome by turning the SIEA flap on its long axis, allowing the pedicle to sit medially with the lateral end of the flap positioned superiorly. The de-epithelialized SIEA flap dermis was in direct contact with the chest wall, enabling its fixation. This method of flap inset provides a valuable solution for medializing the SIEA pedicle while maintaining an aesthetically satisfactory orientation. This technique could be used in ipsilateral SIEA flap breast reconstructions that do not require a skin paddle, as with stacked flaps or following nipple-sparing mastectomy.

Successful endovascular embolization for traumatic subcutaneous abdominal wall hematoma via the superficial inferior epigastric artery: a case report

  • Moon, Sung Nam;Seo, Sang Hyun;Jung, Hyun Seok
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.128-130
    • /
    • 2022
  • Abdominal wall hematoma (AWH) after blunt trauma is common, and most cases can be treated conservatively. More invasive treatment is required in patients with traumatic AWH if active bleeding is identified or there is no response to medical treatment. Herein, we report a case of endovascular embolization for traumatic subcutaneous AWH. Almost endovascular treatment for AWH is done through the deep inferior epigastric artery. However, in this case, the superficial inferior epigastric artery was the bleeding focus and embolization target. After understanding the vascular system of the abdominal wall, an endovascular approach and embolization is a safe and effective treatment option for AWH.

Benchmark for Deep Learning based Visual Odometry and Monocular Depth Estimation (딥러닝 기반 영상 주행기록계와 단안 깊이 추정 및 기술을 위한 벤치마크)

  • Choi, Hyukdoo
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.2
    • /
    • pp.114-121
    • /
    • 2019
  • This paper presents a new benchmark system for visual odometry (VO) and monocular depth estimation (MDE). As deep learning has become a key technology in computer vision, many researchers are trying to apply deep learning to VO and MDE. Just a couple of years ago, they were independently studied in a supervised way, but now they are coupled and trained together in an unsupervised way. However, before designing fancy models and losses, we have to customize datasets to use them for training and testing. After training, the model has to be compared with the existing models, which is also a huge burden. The benchmark provides input dataset ready-to-use for VO and MDE research in 'tfrecords' format and output dataset that includes model checkpoints and inference results of the existing models. It also provides various tools for data formatting, training, and evaluation. In the experiments, the exsiting models were evaluated to verify their performances presented in the corresponding papers and we found that the evaluation result is inferior to the presented performances.