• Title/Summary/Keyword: dedicated test

Search Result 191, Processing Time 0.021 seconds

Thermal Behavior of Spacecraft Liquid-Monopropellant Hydrazine($N_2$$H_4$) Propulsion System (인공위성 단기액체 하이드라진($N_2$$H_4$) 추진시스템의 열적 거동)

  • Kim, Jeong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.1-11
    • /
    • 1999
  • Thermal behavior of spacecraft propulsion system utilizing monopropellant hydrazine ($N_2$$H_4$) is addressed in this paper. Thermal control performance to prevent propellant freezing in spacecraft-operational orbit was test-verified under simulated on-orbit environment. The on-orbit environment was thermally achieved in space-simulation chamber and by the absorbed-heat flux method that implements an artificial heating through to the spacecraft bus panels enclosing the propulsion system. Test results obtained in terms of temperature history of propulsion components are presented and reduced into duty cycles of the avionics heaters which are dedicated to thermal control of those components. The duty cycles are subsequently converted into the electrical power required in the operational orbit. Additionally, cyclic temperature of each component, which was made under thermal-balanced condition of spacecraft, is compared to the acceptable design range and justified from the viewpoint of system verification.

  • PDF

Energy analysis-based core drilling method for the prediction of rock uniaxial compressive strength

  • Qi, Wang;Shuo, Xu;Ke, Gao Hong;Peng, Zhang;Bei, Jiang;Hong, Liu Bo
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • The uniaxial compressive strength (UCS) of rock is a basic parameter in underground engineering design. The disadvantages of this commonly employed laboratory testing method are untimely testing, difficulty in performing core testing of broken rock mass and long and complicated onsite testing processes. Therefore, the development of a fast and simple in situ rock UCS testing method for field use is urgent. In this study, a multi-function digital rock drilling and testing system and a digital core bit dedicated to the system are independently developed and employed in digital drilling tests on rock specimens with different strengths. The energy analysis is performed during rock cutting to estimate the energy consumed by the drill bit to remove a unit volume of rock. Two quantitative relationship models of energy analysis-based core drilling parameters (ECD) and rock UCS (ECD-UCS models) are established in this manuscript by the methods of regression analysis and support vector machine (SVM). The predictive abilities of the two models are comparatively analysed. The results show that the mean value of relative difference between the predicted rock UCS values and the UCS values measured by the laboratory uniaxial compression test in the prediction set are 3.76 MPa and 4.30 MPa, respectively, and the standard deviations are 2.08 MPa and 4.14 MPa, respectively. The regression analysis-based ECD-UCS model has a more stable predictive ability. The energy analysis-based rock drilling method for the prediction of UCS is proposed. This method realized the quick and convenient in situ test of rock UCS.

Individual and School Factors Affecting Critical Thinking Ability among Nursing Students (간호대학생의 비판적 사고능력에 영향을 미치는 개인요인과 학교요인)

  • Shin, Sujin;Park, Inhee;Hwang, Eunhee;Jung, Dukyoo;Kim, Kon Hee
    • Korean Medical Education Review
    • /
    • v.20 no.1
    • /
    • pp.44-50
    • /
    • 2018
  • The purpose of this study was to investigate factors associated with the critical thinking ability of nursing students at the individual and school levels. The study adopted a descriptive design and recruited 465 nursing students from four nursing schools from November 2014 to September 2015 through convenience sampling. The Clinical Critical Thinking Skill Test was used to measure critical thinking ability, and the data were analyzed with the SAS ver. 9.4 program (SAS Institute Inc., Cary, NC, USA) for descriptive statistics, t-test, analysis of variance, and multi-level model. The results showed that clinical practicum experience (${\beta}=-0.72$, p=0.025), taking critical thinking courses (${\beta}=0.63$, p=0.010), and taking simulation courses (${\beta}=0.56$, p=0.035) improved critical thinking ability in the individual level model. In the school level model, the interaction effect between the years of clinical practice done by the student and the presence of full-time clinical instructors was significant (${\beta}=1.29$, p=0.011). These results suggest that critical thinking ability improves with the more years of clinical practice individual nursing students have, and this improvement is greater with the presence of full-time clinical instructors in the school. Therefore, it is recommended that nursing students undergo critical thinking and simulation courses to develop their critical thinking ability, and dedicated clinical instructors in nursing schools should play a vital role.

Development of Lithium-Ion based Onboard Battery for Space Launch Vehicle (우주발사체 탑재용 리튬이온 배터리 개발)

  • Kim, Myung-Hwan;Ma, Keun-Su;Lim, You-Chol;Lee, Jae-Deuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.363-368
    • /
    • 2007
  • Lithium-ion batteries providing high gravimetric energy density are rapidly replacing Ni-Cd and Ni-H2 in aerospace applications. The main advantage is the weight reduction of the battery system. Weight is a major concern in aerospace applications. Also, lithium-ion offer low thermal dissipation, high energy efficiency, and low cell cost. The Onboard battery module for KSLV-I(Korea Space Launch Vehicle) contains 80 Sony US18650 cells configured as 10 strings in parallel, with each string containing 8 series connected cells. This allows to meet voltage and capacity requirements specified for the mission. In this paper design description and specifications of lithium-ion battery developed are presented. Qualification test flow is also shown to make sure the performance in the predicted space environment. Electrical performance was simulated by dedicated program, and verified with electronic load. Lastly, the capacity was proven on real equipment load assembly.

Study on Implementation of a Digital Frequency Discriminator using 4 channel Delay line (4채널 지연선로를 이용한 디지털 주파수 판별기 구현에 관한 연구)

  • Kook, Chan-Ho;Kwon, Ik-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.512-515
    • /
    • 2010
  • SIGINT(SIGnal INTelligence) includes several parameters intercepted by measurement and analysis of the RF(Radio frequency) signal from free space. One of the important parameters is frequency information. Expecially, in order to perform instantaneous frequency measurement of Radar and Missile seeker's RF signals, we use dedicated RF modules as a DFD(Digital Frequency Discriminator) to provide frequency information by measurement of the relative phase difference between signals via intended RF delay lines. It must measure and provide realtime based frequency information on short pulsed RF signal up to 100 nSec or less. This document proposes Ultra wideband DFD consisted of a RF input section of Wideband 4 channel RF delay line and correlator, a digital processing section to measure and provide frequency information from I/Q signal, and a frequency calibration section. Also, it will show design suitability based on test results measured under test condition of very short input pulse signals.

  • PDF

Micro-shear bond strengths of resin-matrix ceramics subjected to different surface conditioning strategies with or without coupling agent application

  • Gunal-Abduljalil, Burcu;Onoral, Ozay;Ongun, Salim
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.180-190
    • /
    • 2021
  • Purpose. This study aimed to assess the influence of various micromechanical surface conditioning (MSC) strategies with or without coupling agent (silane) application on the micro-shear bond strength (µSBS) of resin- matrix ceramics (RMCs). Materials and Methods. GC Cerasmart (GC), Lava Ultimate (LU), Vita Enamic (VE), Voco Grandio (VG), and Brilliant Crios (BC) were cut into 1.0-mm-thick slices (n = 32 per RMC) and separated into four groups according to the MSC strategy applied: control-no conditioning (C), air-borne particle abrasion with aluminum oxide particles (APA), 2W- and 3W-Er,Cr:YSGG group coding is missing. The specimens in each group were further separated into silane-applied and silane-free subgroups. Each specimen received two resin cement microtubules (n = 8 per subgroup). A shear force was applied to the adhesive interface through a universal test machine and µSBS values were measured. Data were statistically analyzed by using 3-way ANOVA and Tukey HSD test. Failure patterns were scrutinized under stereomicroscope. Results. RMC material type, MSC strategy, and silanization influenced the µSBS values (P<.05). In comparison to the control group, µSBS values increased after all other MSC strategies (P<.05) while the differences among these strategies were insignificant (P>.05). For control and APA, there were insignificant differences between RMCs (P>.05). The silanization decreased µSBS values of RMCs except for VE. Considerable declines were observed in GC and BC (P<.05). Conclusion. MSC strategies can enhance bond strength values at the RMC - cement interface. However, the choice of MSC strategy is dependent on RMC material type and each RMC can require a dedicated way of conditioning.

Study of the Validity Test on the Self-monitoring Scale for Primi-Gravida (초임부를 대상으로 한 자가검색도 척도의 타당도 비교)

  • Lee, Seon-Ah
    • Women's Health Nursing
    • /
    • v.4 no.2
    • /
    • pp.173-186
    • /
    • 1998
  • In this study, both the literary survey as well as empirical research has been executed to test the validity of the scales that measure the construct of self-monitoring scale could not be classified into five factors as Snyder suggested. Many other scholars (Briggs, Cheek and Buss, 1980) suggested 3 different classifications which was accepted by Snyder and Gangestad (1986). John, Cheek and Klohnen (1996) claimed a two-factor classification. As has been discussed, factor analysis is used to prove convergent validity within the factor and discriminant validity between the factors. However, depending on the researchers, many variations in classification of the factors were found and a lack of content and discriminant validity was found in the previous research findings. It is also important to note that Snyder's self-monitoring scale, did not factor-load at over 30 for all 25 items, regardless of how many factors could be classified. According to findings of this study, the self-monitoring scale neither classified as five, three or two factors nor factor loaded as hypothesized. It is also clear that Snyder's self-monitoring scale lack convergent validity as the sub-factors of the scale fail to prove its uni-dimensionality. The A self-monitoring scale not only fail to overcome the problems of Snyder's self-monitoring scale but even lost the attractiveness of the self-monitoring scale. In this study, it was also found that the A self-monitoring scale was not classified as hypothesized in either in a two or three-factor classification. It is, of course, not desirable to use any scale that lacks convergent and discriminant validity even though it has been widely used but also has held a great deal of influence on the field of social psychology. To overcome the shortcomings of Snyder's self-monitoring scale, Lennox and Wolfe(1984) suggested 13 items. This study 1. was dedicated to test the validity and reliability of the scale, in which we found that the data presented in validity as the two factors were classified and loaded as expected. Reliability was also proven by checking Cronbach's alpha for each factor and for the total items. In addition, a confirmatory factor analysis was executed for the 13 items using LISREL 8.12 program to confirm convergent validity in a two-factor classification. The model was fitting and sound ; however, the self-monitoring scale was unfitted and not validated. Thus, it is recommended to use not the original or the abbreviated self-monitoring scale but the 13 items in future studies. It should also be noted that items 7 and 13 should be removed to obtain better uni-dimensionality for the 13 items. These items loaded at over .30, too high for the two factors in the test results of factor analysis. In addition, it is necessary to double-check the cause of two-hold loading at over .30 for the two factors. It could be a problem caused by data or by the scale itself. Therefore, additional studies should follow to better clarify this matter.

  • PDF

Fatigue Durability Evaluation of Refraction Expansion Joints (굴절형 신축이음장치의 피로내구성 평가)

  • Na, Jun-Su;Lee, Ta;Han, Eui-Seok;Sung, Won-Kyu;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.10-15
    • /
    • 2017
  • The refraction expansion joints have been newly developed by complementing the problems of shock, noise, replaceability, displacement in the direction perpendicular to bridge, vertical difference, which are problems of existing expansion joints. The Refraction expansion joints are characterized by continuous surfaces with small impact and low noise. The behavior of the Refraction expansion joints performs the bridge expansion behavior by rotation of the link. In the rotational behavior of the link, the bolt is the central axis of the behavior. Therefore, it can be said that the durability of the bolt is very important. However, the theoretical and experimental verification of the bolt durability of the Refraction expansion joint is lacking. In this paper, to verify the fatigue durability of the bolt, test specimens with a 300 mm Refraction expansion joint were fabricated. A strain gauge dedicated to the bolt was installed inside the manufactured test specimen bolt. The test method was applied in accordance with KS F 4425. The fatigue durability of the bolts assembled inside the diaphragm expansion joint was confirmed by the repeated fatigue test of 2,000,000 cycles.

Identification of Patients with Microscopic Hematuria who are at Greater Risk for the Presence of Bladder Tumors Using a Dedicated Questionnaire and Point of Care Urine Test - A Study by the Members of Association of Urooncology, Turkey

  • Turkeri, Levent;Mangir, Naside;Gunlusoy, Bulent;Yildirim, Asif;Baltaci, Sumer;Kaplan, Mustafa;Bozlu, Murat;Mungan, Aydin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6283-6286
    • /
    • 2014
  • In patients with microscopic hematuria there is a need for better identification of those who are at greater risk of harbouring bladder tumors. The RisikoCheck(C) questionnaire has a strong correlation with the presence of urothelial carcinoma (UC) of the bladder and in combination with other available tests may help identify patients who require detailed clinical investigations due to increased risk of presence of bladder tumors. This study aimed to evaluate the efficacy of RisikoCheck(C) questionnaire together with NMP-22(R) (BladderChek(R)) as a point-of-care urine test in predicting the presence of bladder tumors in patients presenting with microscopic hematuria as the sole finding. In this multi-institutional prospective evaluation of 303 consecutive patients without a history of urothelial carcinoma (UC), RisikoCheck(C) risk group assessment, urinary tract imaging and cystourethroscopy as well as urine cytology and Nuclear Matrix Protein-22 (NMP-22 BladderChek) testing were performed where available. The sensitivity, specificity, negative predictive value (NPV), and positive predictive values (PPV) for the risk adapted approach were calculated. All patients underwent cystoscopy, and tumors were detected in 18 (5.9%). Urine cytology and NMP-22 was positive for malignancy in 9 (3.2%) and 12 (7.5%) of patients, respectively. A total of 43 (14%) patients were in the high risk group according to the RisikoCheck(C) questionnaire. The sensitivity and specificity of the questionnaire in detecting a bladder tumor was 61.5 % and 84.0 % in the high risk group. In patients with either a positive NMP-22 test or high risk category RisikoCheck(C), 23.6% had bladder tumors with a corresponding sensitivity of 54.2% and specificity of 88.6%. If both tests were negative only 3.3% of the patients had bladder tumors. The results of our study suggest that the efficacy of diagnostic evaluation of patients with microscopic hematuria may be further enhanced by combining RisikoCheck(C) questionnaire with NMP-22.

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.