• 제목/요약/키워드: decking material

검색결과 6건 처리시간 0.02초

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • 제37권5호
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

초음파 비파괴시험법을 이용한 데크재의 현장평가 (Ultrasonic Nondestructive On-Site Evaluation of Decks in-Service)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권4호
    • /
    • pp.486-493
    • /
    • 2015
  • 설치된 데크재에 대한 성능을 평가하기 위하여 초음파 비파괴시험법을 사용하였다. 먼저 3종류의 데크재에 대해 트랜스듀서의 배치에 따른 직접법과 간접법간의 측정방법간의 차이를 검증하였으며 두 번째로 설치된 데크재의 사용시간의 경과에 따른 초음파속도를 측정 비교하였다. 마지막으로 데크재의 사용수명을 파악하기 위하여 사용시간의 경과에 따른 초음파속도의 변화를 조사하였다. 시험결과 직접법과 간접법간의 측정방법간의 차이는 없는 것으로 나타났으며 직접법에 대한 간접법의 비율은 1.02와 1.05로 각각 나타났다. 설치된 데크재에서 시간의 경과에 따라 초음파 속도는 감소하였으며 이들 간의 관계는 선형으로 나타났다. 시험결과로부터 초음파 비파괴시험법은 설치된 데크재의 유지보수에 관한 효율적인 수단이 될 수 있을 것으로 생각된다.

수종별 목재 데크재의 내구성에 관한 연구 (Study on Durability of Wood Deck according to Species)

  • 김경중;이원재;최철;김희진;강석구
    • 한국가구학회지
    • /
    • 제28권2호
    • /
    • pp.111-117
    • /
    • 2017
  • Recently, as people's interest in wood has increased, the use of wood as household and landscape decking materials has increased. As the deck material, imported wood such as synthetic wood, Ipe, and Malas was used in addition to the existing preserved wood, but recently deck use has been activated as part of the activation of domestic materials. As an important quality factor in the selection of such decking materials, various durability along with weatherability for long - term use is required for maintenance. Generally used tropical hardwoods have excellent weatherability and durability without additional preservative treatment. However, the domestic larch is a wood species with a higher specific gravity and durability than ordinary conifers. However, it has not yet been used as a deck material due to lack of comparative studies on its characteristics. Therefore, hardness and durability of wood were measured using six specimens of Ipe, Massaranduba, Malas, Douglas-fir, Larch and Torrefied-Larch. Density Profile was used to measure the density, and Brinell hardness test and resistance test against momentary impact were carried out for the test of resistance to static load. Also, The hardness and durability of wood were measured by castor test with resistance test against dynamic load, as well as, nail down test by experiment on surface hardness and durability. As a result of the experiment, the hardness was increased in proportion to the density, and it was confirmed that the imported lumber was harder and durable than the domestic larch.

뉴 미디어 건축의 설계방법에 관한 고찰 - 伊東豊雄의 센다이 미디어테크를 中心으로 - (A Research on the design method of New Media Architecture in Sendai mediatheque - Based on the Sendai Mediatheque by Toyo Ito -)

  • 김기수;조용수
    • 한국실내디자인학회논문집
    • /
    • 제36호
    • /
    • pp.14-21
    • /
    • 2003
  • The Propose of this research was to consider how the New Media Architecture was applied to contemporary architecture according to the analysis of the design method process of Toyo Ito. Sendai Mediatheque by Toyo Ito stands as one of the most symbolic statement In New Media architecture. The four principal architectural elements of the Mediatheque are the digital image, the continuous space, the tube, and the skin facade. The digital image express forms of communication, person-to-person and person-to-thing, and they vary according to the media utilized on each level. The three skin elements of the Mediatheque are a double skin of MPG, skin of louvers, skin of fine-floor decking. The tubes act as columns while enveloping light, air, water, electricity the passage of people, as well as the means of transferring material. The thirteen tubes of different sizes prevent the erection of wall and suggest places instead of rooms. Instead of being limited to certain specified actions in clearly defined rooms, people are free to choose places for their actions in the continuous space.

목재 데크재의 초음파 비파괴시험에 의한 인위적인 결함의 영향평가 (Evaluation of Influences of Artificial Defect of Wood Deck Using Non-destructive Ultrasonic Testing)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.1-8
    • /
    • 2016
  • 목재 데크재에 인위적인 결함인 구멍을 부여하고 이들의 성능평가를 위해 초음파 비파괴 시험법을 적용하였다. 구멍의 크기와 개수를 달리하여 각각에 대한 초음파 전달속도를 측정하고 탄성계수를 산정하여 그 영향을 비교분석하였다. 시험결과 구멍의 크기가 커짐에 따라 초음파 전달속도와 탄성계수는 감소하였으며 이들 상호간에는 직선상관관계를 보였다. 구멍의 크기가 증가하면 초음파의 전달 길이는 증가하며 이에 따라 초음파속도는 감소하였지만 구멍의 크기가 15 mm 이하로 작은 경우에는 구멍이 없는 부재에 비해 그 차이가 작게 나타났다. 구멍의 개수가 많아짐에 따라 초음파 전달속도와 탄성계수는 감소하였으며 이들 상호간에는 높은 직선상관관계를 보였다. 구멍의 개수가 3개인 경우 초음파속도는 약 3.5% 정도 감소한데 비하여 탄성계수는 27% 정도로 현저히 감소하여 더 큰 감소경향을 나타내었다. 이들의 결과로부터 구멍의 크기와 개수는 초음파 전달속도와 탄성계수에 영향을 미치며 구멍의 크기가 크고 개수가 많아질수록 그 영향은 더욱 커질 것으로 여겨진다. 또한 작은 결함의 탐지를 위해서는 초음파 전달속도에만 의지할 것이 아니라 여러 초음파 변수를 고려하여 적용하는 방법을 고려하여야 할 것으로 생각된다.

AUTODYN을 이용한 하프장전 발파공법의 에어데크 효과에 대한 수치해석적 연구 (Numerical Study on the Effects of Air Decking in Half Charge Blasting Using AUTODYN)

  • ;김정규;김승준;;정승원;양형식;김남수;김종관
    • 화약ㆍ발파
    • /
    • 제36권4호
    • /
    • pp.1-8
    • /
    • 2018
  • 본 수치해석 연구는 하프장전 발파법의 채광발파 및 터널발파에의 적용성을 평가하기 위해 수행되었다. 하프장전 발파란 한 차례의 천공공정 중에 설계된 공깊이보다 2배로 깊은 발파공을 미리 천공한 다음, 연속적인 두 차례의 발파공정을 통해 굴착하는 방법을 말한다. 이 방법의 목표는 발파효율의 향상뿐만 아니라 광산발파나 터널굴착 프로젝트에서 공사비용과 공기를 단축시키는 데 있다. 본 연구에서는 ANSYS AUTODYN 프로그램 상의 Euler-Lagrange 해석기를 사용하여 몇 차례의 해석을 실시함으로써 제안된 방법이 지하굴착에서의 발파결과에 어떠한 영향을 미치는지를 확인하였다. 해석모델은 오일러 모델(폭약, 공기 및 전색 재료)과 라그랑쥬 모델(암석 재료)로 구성되어 있다. 해석 결과, 제안된 발파방법의 경우에는 긴 발파공의 바닥부에 형성되는 에어데크로 인하여 통상의 발파방법에 비해 발파공 부근에서 더 높은 충격압력과 입자속도를 발휘하는 것으로 나타났다.