• 제목/요약/키워드: deck slab

검색결과 254건 처리시간 0.028초

VES-LMC로 보수.보강된 구조물의부착강도에 미치는 Hydrodemolition의 영향 (Effect of Hydrodemolition on Bonding Strengthof Structures Repaired or Rehabilitated with VES-LMC)

  • 김성권;심도식;이봉학;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.397-400
    • /
    • 2006
  • Most of the civil structures in Korea and abroad have many kinds of damages when they are facing over-loaded traffics, long-term serviceability, and severe environmental conditions. Repair, rehabilitation, and retrofit are important for maintaining the serviceability of structures. In recent year, VES-LMC has been widely used as repair material for bridge deck repair and rehabilitation, because the VES-LMC has a various benefits such as traffic opening after 3 hours of curing, higher durability and bond strength. In case of any structure repaired or rehabilitated with VES-LMC, those were influenced capacity of bond between the base layer of slab and VES-LMC as well as physical properties of each other materials. The capacity of bond depended on purity of interface, micro cracks, curing of VES-LMC and so like. A kind of popular concrete repair technique, High pressure water jetting equipment is extremely efficient at removing damaged concrete. Removing damaged or poor quality concrete from sensitive structures such as bridge, tunnels, multi-story car parking decks and runways, using the high pressure water jetting could remove damaged or poor quality concrete remaining healthy and sound concrete. Accordingly, the purpose of this study is that it was to evaluate effect of hydrodemolition on the bond strength of VES-LMC overlay compared with effects of other method such as breaker, untreated. Also, it was evaluated the effect of surface moisture.

  • PDF

철골 프리캐스트 콘크리트 합성보 성능 분석 연구 (Load carrying capacity of Structural Composite Hybrid System (Green Frame))

  • 홍원기;김선국;김승일
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2010
  • An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. The composite beams tested in this study were designed to reduce the depth of the slab and beam. The slabs are constructed on top of the edges of the Structural Composite Hybrid System, instead of on top of the steel flange, decreasing the depth of the beams. When concrete is cast on the metal deck plate located on the edges of the precast concrete, the weight of the concrete slabs and other construction loads must be supported by the contacts between the steel and the precast concrete. This interface must not exhibit bearing failures, shear failures, and failures caused by torque due to the loading of the precast concrete. When the contact area between the concrete and the bottom flange of the steel beam is small, these failures of the concrete are likely and must be prevented. The premature failure of precast concrete must not also be present when the weight of the concrete slabs and other construction loads is loaded. This paper presents a load carrying capacity of Structural Composite Hybrid System in order to observe the failure mode. The symmetrically distributed loading that caused the failure of the composite beam was found. The paper also provides design recommendations of such type of composite structure.

Numerical simulation approach for structural capacity of corroded reinforced concrete bridge

  • Zhou, Xuhong;Tu, Xi;Chen, Airong;Wang, Yuqian
    • Advances in concrete construction
    • /
    • 제7권1호
    • /
    • pp.11-22
    • /
    • 2019
  • A comprehensive assessing approach for durability of reinforced concrete structures dealing with the corrosion process of rebar subjected to the attack of aggressive agent from environment was proposed in this paper. Corrosion of rebar was suggested in the form of combination of global corrosion and pitting. Firstly, for the purposed of considering the influence of rebar's radius, a type of Plane Corrosion Model (PCM) based on uniform corrosion of rebar was introduced. By means of FE simulation approach, global corrosion process of rebar regarding PCM and LCM (Linear Corrosion Model) was regressed and compared according to the data from Laboratoire $Mat{\acute{e}}riaux$ et $Durabilit{\acute{e}}$ des Constructions (LMDC). Secondly, pitting factor model of rebar in general descend law with corrosion degree was introduced in terms of existing experimental data. Finally, with the comprehensive numerical simulation, the durability of an existing arch bridge was studied in depth in deterministic way, including diffusion process and sectional strength of typical cross section of arch, crossbeam and deck slab. Evolution of structural capacity considering life-cycle rehabilitation strategy indicated the degradation law of durability of reinforced arch bridges.

Acoustic emission localization in concrete using a wireless air-coupled monitoring system

  • Yunshan Bai;Yuanxue Liu;Guangjian Gao;Shuang Su
    • Smart Structures and Systems
    • /
    • 제32권4호
    • /
    • pp.195-205
    • /
    • 2023
  • The contact acoustic emission (AE) monitoring system is time-consuming and costly for monitoring concrete structures in large scope, in addition, the great difference in acoustic impedance between air and concrete makes the detection process inconvenient. In this work, we broaden the conventional AE source localization method for concrete to the non-contact (air-coupled) micro-electromechanical system (MEMS) microphones array, which collects the energy-rich leaky Rayleigh waves, instead of the relatively weak P-wave. Finite element method was used for the numerical simulations, it is shown that the propagation velocity of leaky Rayleigh waves traveling along the air-concrete interface agrees with the corresponding theoretical properties of Lamb wave modes in an infinite concrete slab. This structures the basis for implementing a non-contact AE source location approach. Based on the experience gained from numerical studies, experimental studies on the proposed air-coupled AE source location in concrete slabs are carried out. Finally, it is shown that the locating map of AE source can be determined using the proposed system, and the accuracy is sufficient for most field monitoring applications on large plate-like concrete structures, such as tunnel lining and bridge deck.

복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구 (Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel)

  • 박진욱;유용호;김양균;박병직;김휘성;박상헌
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.167-175
    • /
    • 2019
  • 차량화재가 대부분인 터널 화재 사고에 효과적으로 대응하기 위해서는 초기에 화재를 진압하는 것이 가장 효율적이다. 그러나 도심지 터널의 경우 화재 사고시 차량 정체로 인해 소방대 투입이 어려워 신속한 소화 활동에 제약을 받으며, 이러한 문제는 최근 장대화 및 대심도화 되고 있는 지하도로(복층터널)의 경우 더욱더 심하게 나타날 것으로 판단된다. 국내의 경우 터널에서 발생되는 재난 재해에 대비하여 터널연장과 터널 조건별로 정해지는 위험도 지수를 토대로 연장등급과 방재등급을 산정하여 방재시설 설치 범위를 규정하고 있으며, 특히 터널 화재에 직접적으로 대응하기 위한 설비로 소화기구, 옥내소화전설비, 물분무설비 등을 등급에 따라 기본시설로 지정하고 있다. 그러나 이런 소화설비는 현실적으로 기능적이고 기술적인 측면에서 많은 약점이 발생되어 개선방안이 필요한 실정이다. 특히, 하나의 단면을 중간 슬래브로 나눠 상하행선으로 사용하는 형태인 복층터널의 경우 일반 소화설비보다 더 신속하고 효과적으로 화재 진압이 가능한 설비가 필요할 것으로 판단된다. 따라서 본 연구에서는 기존 터널 방재시설(소화설비)이 가지는 문제점을 보완하고, 복층터널의 구조적 특수성에 최적화된 원격 자동소화 시스템을 개발하였다. 그 결과로 낮은 층고를 고려한 장거리용 설비와 보급성을 확대한 옥내소화전용 설비 등 두 가지 형태의 시스템 개발을 완료하여 성능을 검증하였으며, 실제 터널에 보급되어 널리 활용될 수 있도록 현재 실용화를 추진 중에 있다.

전기로(電氣爐) 산화(酸化)슬래그 잔골재를 이용한 교면포장(橋面鋪裝) 시 단위질량(單位質量) 증대(增大)에 따른 슬래브 단면력(斷面力) 검토(檢討) (Investigation of Sectional Force on Increasing of Dead Load with Bridge Deck Overlay using Electric Arc Furnace Slag Sand)

  • 정원경;전범준;길용수
    • 자원리싸이클링
    • /
    • 제22권2호
    • /
    • pp.62-70
    • /
    • 2013
  • 전기로 산화슬래그를 콘크리트용 잔골재로 사용하기 위해서는 제철소에서 제강과정에서 불안정한 용융상태의 제강슬래그를 에이징처리하여 안정된 구조로 변환시켜 이온이나 전자의 이동을 억제, 슬래그의 화학적 물리적 저항성을 증대시켜 사용하여야 한다. 우리나라에서는 전기로 산화슬래그 잔골재를 콘크리트용 잔골재로 활용하기 위한 제도적 기반으로서 KS F 4571이 제정되어 부산물의 자원화 시스템 기반이 마련되었다. 본 연구에서는, 전기로 산화슬래그 잔골재를 PMC(Polymer Modified Concrete) 포장공법에 잔골재로 치환하였을 경우, 콘크리트의 고정하중 증가에 따른 교량 상부에 미치는 영향에 대하여 연구하고자 하였다. 본 연구에서는 선정된 4가지 형식의 교량(RC 슬래브교, RC 라멘교, PSC Beam교, Steel Box girder교) 포장의 단위질량이 상향 적용시, 포장하중 증가에 따른 전체 고정하중은 약 1~2% 이내로 증가하고, 하중조합에 의한 부재력(설계모멘트)은 약 2% 이내로 증가하였다. 그리고 포장하중 증가에 따른 대상 구조물의 단면검토를 수행한 결과, 단면 안전율이 약 3% 이내로 감소하였다. 따라서, 포장의 단위질량 증가로 인해 구조물의 구조적 안전성에는 영향을 미치지 않을 것으로 판단된다.

HI-FORM DECK를 이용한 부분 PC 계단 접합부의 접합방식에 따른 실험적 연구 (A study on experiment from the Stair Joints Constructed with PC system part of it using the HI-FORM DECK)

  • 장극관;이은진;진병창;강우주;한태경
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.9-12
    • /
    • 2008
  • 반강접합은 핀접합의 단점을 보완하고 강접합의 장점을 수용할 수 있는 중간 형태이다. 현재 국내에서 핀접합에 대한 연구는 활성화 되어있으나 반강접합에 대한 연구는 많지 않기 때문에 본 연구에서는 3가지 형태의 실험체를 제작하여 성능을 입증하려 했다. 실험체는 강접합 HI-R, 반강접합 HI-S, 핀접합 HI-P등 총 3개이다. 실험결과 HI-R은 접합부 전단파괴, HI-S는 고정단 상부 휨파괴, HI-P는 경사계단 슬래브 하부 휨파괴로 나타났고 최대내력은 각각 51.74, 51.4, 24.63kN으로 측정되었고, 강성은 1.58, 1.19, 0.37을 나타냈다. 항복강도는 각각 44.5, 47.3, 24kN을 보유하고, 연성비는 3.31, 2.32, 1.54로 나타냈고, 사용하중 작용 시의 처짐은 KBC기준에 의거하여 HI-P실험체가 기준을 초과하는 것으로 나타났다. 철근 변형률분포로 보아 HI-S는 초기에 HI-R과 유사한 거동을 보이나 항복이후 접합부 내부요소들의 응력분담으로 핀접합보다는 우수한 성능을 보유한 반강접 접합부로 판단할 수 있었다.

  • PDF

UHPC 바닥판 슬래브의 뚫림전단강도 (Punching Shear Strength of Deck Slabs Made of Ultra High Performance Concrete)

  • 조창빈;김병석;황훈희;최경규;최석환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.221-231
    • /
    • 2011
  • 강섬유보강 초고성능 콘크리트(UHPC)는 압축강도가 200MPa에 이르고, 강성 및 인성이 크기 때문에 이를 이용하면 구조 부재를 얇고 가볍게 설계하는 것이 가능하다. 본 논문은 UHPC를 교량의 바닥판 슬래브에 적용하기 위해서 뚫림전단(punching shear)에 대한 저항능력을 평가한 것이다. 6개의 정사각형 슬래브를 제작하여 4변 완전고정 상태에서 뚫림전단 실험을 수행하였다. 슬래브의 두께는 40mm와 70mm였고, 재하판의 형상비는 1.0~2.5 범위였다. 40mm 실험체는 최대하중 이후에 연성적인 변형률 연화구간이 길고, 70mm 실험체는 상대적으로 더 취성적인 뚫림파괴를 보였다. 기존의 여러 뚫림전단강도 평가식을 이용하여 실험결과를 분석하였는데, 두께가 작은 40mm 실험체에서는 Ductal$^{(R)}$ 및 JSCE의 식이, 그리고 70mm 실험체에서는 Harajli et al. 및 ACI-Ductal$^{(R)}$의 제안식이 상대적으로 실험에 근접한 값을 예측하였다. 그러나 전반적으로 실험결과를 잘 예측하지 못하였으므로 실제 파괴메커니즘에 근거한 새로운 식을 제안하였다. 새로 제안한 식은 실험결과를 비교적 잘 예측하는 것으로 나타났다.

교량 상 자갈궤도의 종저항력 측정을 위한 실험 연구 (An Experimental Study for Longitudinal Resistance of Ballast Track on Bridge)

  • 민경환;윤경민
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.173-178
    • /
    • 2016
  • 콘크리트 교량 상에 고속철도의 자갈 궤도가 시공될 경우 장대 레일의 종방향 변위가 고정된 반면 교량 바닥판 슬래브의 종방향 변위가 고정되지 않고, 온도 하중과 외부 하중에 의해 교량과 레일의 상대 변위가 발생한다. 현재 장대 레일 자갈 궤도에 대한 종방향 저항력(KR C-08080, UIC code 774-3)은 교량의 종방향 변위와 자갈 궤도와 콘크리트 슬래브 사이의 마찰력을 고려하고 있지 않다. 또한 종방향 저항력 값은 다소 보수적이어서 철도교의 장경간 및 연속화에 불리한 요소로 작용하고 있다. 따라서 실제의 거동을 보다 효과적으로 반영하기 위해 장대 레일의 종저항력은 콘크리트 슬래브와 궤도 사이의 추가적인 강성을 고려해야 한다. 본 연구에서는 콘크리트 바닥판과 도상 궤도를 모사한 실대형 실험체(mock-up test specimen)를 제작하여, 교량 상에 설치된 도상 궤도의 종저항력을 측정하였고, 또한 차륜 하중의 재하 유무에 대해서도 그 거동을 평가하였다. 실험 결과, 최대 종저항력은 현재의 코드와 유사한 경향을 보였으나, 한계 변위까지의 강성은 현재의 코드보다 실험 결과가 작게 측정되는 것으로 나타났다.

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가 (Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges)

  • 김현호;심창수;윤광중;이필구
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.549-559
    • /
    • 2005
  • 철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.