• Title/Summary/Keyword: deck slab

Search Result 254, Processing Time 0.023 seconds

Design thermal loading for composite bridges in tropical region

  • Au, F.T.K.;Cheung, S.K.;Tham, L.G.
    • Steel and Composite Structures
    • /
    • v.2 no.6
    • /
    • pp.441-460
    • /
    • 2002
  • In the design of bridges, it is important to consider the thermal stresses induced by the non-linear temperature distribution as well as the variation of effective temperature in the bridge deck. To cope with this, design temperature profiles are provided by design codes, which are normally based on extensive research work. This paper presents the results of a comprehensive investigation on the thermal behaviour of bridges in Hong Kong with special emphasis on composite bridges. The temperature distribution in bridges depends primarily on the solar radiation, ambient air temperature and wind speed in the vicinity. Apart from data of the meteorological factors, good estimates of the thermal properties of material and the film coefficients are necessary for the prediction of temperature distribution. The design temperature profiles for various types of composite bridge deck with bituminous surfacing and concrete slab of different thicknesses are proposed. The factors affecting the design effective temperature are also reviewed and suitable values for Hong Kong are proposed. Results are compared with recommendations of the current local code. The method facilitates the development of site-specific temperature profiles for code documents, and it can also be applied to create zoning maps for temperature loading for large countries where there are great climatic differences.

Effects of Composite Floor Slab on Seismic Performance of Welded Steel Moment Connections (철골모멘트 용접접합부의 내진성능에 미치는 합성슬래브의 영향)

  • Lee, Cheol Ho;Jung, Jong Hyun;Kim, Jeong Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.385-396
    • /
    • 2014
  • Traditionally, domestic steel design and construction practice has provided extra shear studs to moment frame beams even when they are designed as non-composite beams. In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange side was prevalent. The upward moving of the neutral axis due to the composite action between steel beam and floor deck was speculated to be one of the critical causes. In this study, full-scale seismic testing was conducted to investigate the side effects of the composite action in steel seismic moment frames. The specimen PN700-C, designed following the domestic connection and floor deck details, exhibited significant upward shift of the neutral axis under sagging (or positive) moment, thus producing high strain demand on the bottom flange, and showed a poor seismic performance because of brittle fracture of the beam bottom flange at 3% story drift. The specimen DB700-C, designed by using RBS connection and with the details of minimized floor composite action, exhibited superior seismic performance, without experiencing any fracture or concrete crushing, almost identical to the bare steel counterpart (specimen DB700-NC). The results of this study clearly indicate that the beams and connections in seismic steel moment frames should be constructed to minimize the composite action of a floor deck if possible.

A Study on Strength of Shear Connectors in Composite Beams of Steel and Lightweight Concrete Slabs (경량콘크리트 슬래브와 철골보의 합성보에서 쉬어 코넥터의 강도에 관한 연구)

  • 주기수;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.356-361
    • /
    • 1994
  • From the previous experimental test results, it has shown that shear that shear strength in lightweight concrete beams was about 85% on that in normal concrete beams. It is speculated that shear connectors in composite beams of steel and lightweight concrete associated with the longitudinal shear strength decrease more in strength than those in normal concrete. So this paper, as a study on strength of shear connectors in composite beams of steel and lightweight concrete slabs, has a purpose to compare the strength formula resulted from the push-out test of thirteen solid slab and four deck Plate slab with the established ones, and then to suggest a proper strength formula of the shear connectors. The established strength formula of the shear connectors is prescribed for $P_ps = 0.50A_s . \sqrt{f_C . E_C}$by AISC coed, but from the experimental test results the strength values of the shear connectors in lightweignt concrete slabs shows about 70% on those of the shear connectors in normal concrete slabs by AISC code. Therefore, as a strength formula this paper suggests to multiply the established strength formula by reduction factor$(\varphi=0.7)$.

  • PDF

A Simple and Accurate Analysis of Two Dimensional Concrete Slab for a Railroad Bridge by the Composite Laminates Plate Theory (복합적층판 이론에 의한 2차원 콘크리트 슬래브 철도교량의 정확하고 간단한 해석)

  • Han, Bong-Koo;Bang, Bae-San
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.2
    • /
    • pp.20-25
    • /
    • 2011
  • In this paper, two dimensional concrete slabs for a railroad bridge were analyzed by the specially orthotropic laminates theory. Both the geometrical and material property of the cross section of the slab was considered symmetrically with respect to the neutral surface so that the bending extension coupling stiffness, $B_{ij}$ = 0, and $D_{16}=D_{26}=0$ Bridge deck behaves as specially orthotropic plates. In general, the analytical solution for such complex systems is very difficult to obtain. Thus, finite difference method was used for analysis of the problem. In this paper, the finite difference method and the beam theory were used for analysis.

Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea (한국고속철도 천안역사에 대한 소음 및 진동영향 연구)

  • Kweon Young-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

Test research of Structural Safety for Steel Wire-Integrated Deck Plate System (철선일체형 데크 플레이트 구조성능평가를 위한 실험적 연구)

  • Lee, Yong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.220-228
    • /
    • 2010
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of a slab or formwork such as shores and supports, and it is already widely applied in many construction fields. This study selected upper and lower steel wires, lattice steel wires, span, and cutting methods of ends as variables, and conducted an experimental test by manufacturing a total of 32 full scale test bodies. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test bodies, and for a 3.2m-span test body, there was no big problems in using ${\Phi}4.5$ of lattice steel wires.

Development of Steel Wire-Integrated Deck Plate Applicable to Slab with 180mm Thickness (두께 180mm 슬래브에 적용 가능한 철선일체형 데크 플레이트 개발)

  • Lee, Yong Jae;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.89-98
    • /
    • 2012
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of slabs or formworks such as shores and supports, and it is already widely applied in many construction fields. In this research, experimental tests for 14 full scale specimens, which are in the same field conditions, are conducted on several parameters such as the diameter of top, bottom and lattice steel wire, cutting methods of ends. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test specimens, and for a 4.0m-span test specimen, there was no big problems in using bottom bar D7 or D8.

Fatigue Durability of Cramp Joint at Precast Highway Deck Slabs (프리캐스트 바닥판용 클램프 조인트의 피로내구성)

  • Kim, Yoon Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.156-162
    • /
    • 2008
  • The fatigue durability test using the actual size beam was performed with a cramp joint in order to apply to the highway bridge deck slab. Three types of beam were investigated for durability performance by considering stress conditions in real bridge deck slabs, 1) A beam with major shear force applied at the joint (RC Type) 2) A beam with major bending moments applied at the joint (PSC Type) 3) A beam with the pure shear applied at the joint. The experiment for beams with cramp joints showed that the cramp joint had enough durability for fatigue regardless of the overlaid length of the looped distribution bars under the current design strength level. Moreover, it was clarified that the enough durability for fatigue under the load repetition was achieved by increasing the joint span grater than 1.5D with the consideration of the deformation due to reduction in joint stiffness.

Experimental Study of Low-Frictional Behavior for Sliding Slab Track (슬라이딩 궤도의 저마찰 거동에 대한 실험적 연구)

  • Kim, Tae-Gu;Jung, Dong-Ki;Lee, Kyoung-Chan
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.241-247
    • /
    • 2017
  • Railway bridges with continuously welded rail have a limitation of span length due to track-bridge interaction. In order to overcome this, a sliding slab track system has been developed that comprises with a low-frictional sliding layer between the bridge deck and the track slab to isolate the longitudinal behavior between the bridge and the track. In this study, a real scale track system is prepared to experimentally evaluate the longitudinal frictional behavior. Applied loading rates were 0.2, 1.0, 5.0 and 10mm/min; vertical mass on the track are track slab only, 5,000 and 10,000kg added mass, respectively. Test results showed that the resulting frictional coefficients varied from 0.22 to 0.33. In addition, 10,000 cycle loadings were applied to simulate repetitive sliding to represent 30 years of service life. The frictional coefficient increase was measured and found to be 7% of that of the initial loading stage, which means that the sliding layer is adequate to provide low-frictional behavior for the sliding slab track system. Effects of changes of the frictional coefficient of the sliding layer were analyzed by rail-structure interaction analysis.

The Experimental Study of Full-scale Centrifugal Formed High Strength Concrete Prismatic Beam(CFPB) Composited with Deck Slab (상부 슬래브와 합성된 원심성형으로 제작된 초고강도 각형보의 실험연구 )

  • Doo-Sung Lee;Sung-Jin Kim;Jeong-Hoi Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.19-29
    • /
    • 2023
  • An ultra-high strength prestressed prismatic beam of 100 MPa in compressive strength was developed by increasing the watertightness of concrete by utilizing centrifugal molding processes without adding expensive admixtures such as silica fume. The ultra-high strength centrifugal shaped square beam installed on the wall is composited with the upper slab concrete and then subjected to a service load. Horizontal shear stress is generated by bending between the centrifugal molding beam and the floor plate, which causes the beam and floor plate to perform composite behavior through shear connections such as studs and rebars. In this study, a flexural load test was performed on a mock-up specimen that was synthesized by fabricating an RC slab on top of a 100 MPa-class centrifugal shaped beam produced at the factory. proven reliability.