• Title/Summary/Keyword: decade

Search Result 2,779, Processing Time 0.029 seconds

Clinical Observation of Esophageal Cancer (식도암의 임상적 고찰)

  • 정영환
    • Journal of Chest Surgery
    • /
    • v.5 no.2
    • /
    • pp.159-164
    • /
    • 1972
  • Clinical observation is made in 29 cases of patients with esophageal cancer at Department of Chest Surgery in Chunnam University Hospital. 1] The prevalent age of male patient is fifth decade and of female is fourth and fifth decade. The average age of patient is 54 years old. 2] Duration of the disease before admission is relatively long, the duration within 7-9 months is 35% of all patients. 3] On the majority of patients, typical symptoms of esophageal cancer were manifested. 4] Operation was performed on 58% of all patients, in 23% curative and in 35% palliative resection was done.

  • PDF

InSnZnO 산화물 반도체 박막의 열처리 영향에 따른 박막 트랜지스터의 전기적 분석

  • Lee, Jun-Gi;Han, Chang-Hun;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.245-245
    • /
    • 2012
  • 차세대 디스플레이로 각광받고 있는 AMOLED에 대한 관심이 높아짐에 따라 구동 소자의 연구가 활발히 이루어지고 있다. 산화물 반도체 박막 트랜지스터는 비정질 실리콘 박막 트랜지스터에 비해 100 $cm^2$/Vs 이하의 높은 이동도와 우수한 전기적 특성으로 AMOLED 구동 소자로서 학계에서 입증되어왔고, 현재 여러 기업에서 산화물 반도체를 이용한 박막 트랜지스터 제작 연구가 활발히 이루어지고 있다. 본 연구는 열처리 조건을 가변하여 제작한 산화물 반도체 박막 트랜지스터의 전기적 특성 분석을 목적으로 한다. 실리콘 기판에 oxidation 공정을 이용하여 SiO2 100 nm, DC스퍼터링을 이용하여 ITZO (Indium-Tin-Zinc Oxide) 산화물 반도체 박막 50 nm, 증착된 산화물 반도체 박막의 열처리 후, evaporation을 이용하여 source/drain 전극 Ag 150 nm 증착하여 박막 트랜지스터를 제작하였다. 12 sccm의 산소유량, 1시간의 열처리 시간에서 열처리 온도 $400^{\circ}C$, $200^{\circ}C$의 샘플은 각각 이동도 $29.52cm^2/V{\cdot}s$, $16.15cm^2/V{\cdot}s$, 문턱전압 2.61 V, 6.14 V, $S{\cdot}S$ 0.37 V/decade, 0.85 V/decade, on-off ratio 5.21 E+07, 1.10 E+07이었다. 30 sccm의 산소유량, 열처리 온도 $200^{\circ}C$에서 열처리 시간 1시간, 1시간 30분 샘플은 각각 이동도 $12.27cm^2/V{\cdot}s$, $10.15cm^2/V{\cdot}s$, 문턱전압 8.07 V, 4.21 V, $S{\cdot}S$ 0.89 V/decade, 0.71 V/decade, on-off ratio 4.31 E+06, 1.05 E+07이었다. 산화물 반도체의 열처리 효과 분석을 통하여 높은 열처리 온도, 적은 산소의 유량, 열처리 시간이 길수록 이동도, 문턱전압, $S{\cdot}S$의 산화물 박막 트랜지스터 소자의 전기적 특성이 개선되었다.

  • PDF

RADIOLOGICAL EVALUATION OF TEMPOROMANDIBULAR JOINT DISORDERS FOLLOWED BY CLINICAL SYMPTOMS (임상증상에 따른 악관절이상의 방사선학적 소견에 대한 비교연구)

  • Park Tae-Won;You Dong-soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • The authors analyzed the clinical findings, radiological findings and their correlations in the temporomandibular joint disorders. The results were as follows: 1. The most prevalent age group was in the first decade, then the second decade and the third decade. Female were more common with a ratio of 3.4:1. 2. The most common clinical findings was the pain on open mouth position (42.3%), then came the clicking and limitation of mouth opening. 3. The most common bone change on the condyle side was the erosion, then came the flattening, the osteopyte and the sclerosis in that orders. 4. In the case of the crepitus, the coarse crepitus showed more radiological change than the fine crepitus. The 27% of the patients with crepitus showed the bone change and the patients with crepitus showed more bone change than any other clinical symptoms. 5. In the case of the mouth opening limitation, the evaluation of the translatory movement by transcranial projection was in accordance with the clinical evaluation. 6. The correlation between the clinical symptom and the condylar position within the mandibular fossa was not present and in the case of diagnosis of disc displacement, the transcranial projection seemed not to be able to substitute for the arthrography. Radiographically, the most prevalent age group which showed the bone change was in the first, the second and the third decade. And the bone change seemed to have no relationship with aging.

  • PDF

Preparation of a New $K^{+}-ISFET$ Modified with 4'-Aminobenzo-15-crown-5 and Its Response Characteristics (4'-Aminobenzo-15-crown-5를 수식한 새로운 $K^{+}-ISFET$의 제조와 감응특성)

  • Lee, H.L.;Yun, J.H.;Yang, S.T.;Jung, D.S.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A new potassium sensitive field effect transistor modified with 4'-aminobenzo-15-crown-5 was prepared and its response characteristics were evaluated. The response slope of $K^{+}-ISFET$ for pH was 30.0 mV/decade and the response time was mere than 3 minutes. And the response slope and time of the $K^{+}-ISFET$ for potassium ion as $19.5{\pm}0.2{\;}mV/decade$ and about 3 minutes, respectively. The linear response range of the sensor for potassium ion was $2.0{\times}10^{-4}{\sim}1.0{\times}10^{-2}M$. The selectivity coefficients of the $K^{+}-ISFET$ for the alkali and alkaline earth metal ions were also evaluated. Sodium, ammonium and calcium ions exhibited relatively significant interference. The long term stability of the sensor was remarkably improved and it could be used for more than 50 days.

  • PDF

Shifts in Kimchi Consumption between 2005 and 2015 by Region and Income Level in the Korean Population: Korea National Health and Nutrition Examination Survey (2005, 2015) (최근 10년간 한국인의 지역별·소득수준별 김치섭취 변화: 2005년, 2015년 국민건강영양조사 자료 이용)

  • Park, Junghyun;Lee, Hae-Jeung
    • Korean Journal of Community Nutrition
    • /
    • v.22 no.2
    • /
    • pp.145-158
    • /
    • 2017
  • Objectives: The importance of kimchi as a traditional food in Korean cuisine has gradually decreased due to rapid industrialization, economic growth and changes in dietary patterns in Korea. This study aimed to examine the shifts in kimchi consumption by region and by income level between 2005 and 2015 in Korea. Methods: Data from the Korea National Health and Nutrition Examination Surveys III (2005) and VI (2015) were used in the study (n=15,558). Intake of kimchi was estimated using a single 24-hour dietary recall. The sample weights were applied in all analyses to reflect population estimates. All statistical analyses were carried out by using SPSS IBM Statistics 20. Results: Kimchi intake has significantly decreased by 27.6 g/day per capita during the last decade in Korea; 25.0 g for males and 29.9 g for females, respectively. Over the past decade, the decline of kimchi intake has been particularly significant in Seoul, Busan, Incheon, Gyeonggi, and Gwangju, while there has been no significant change in males living in rural areas. The consumption of kimchi across all income levels has decreased, however, the decrease was higher in 'middle and low income level'. The amount of kimchi consumption in 2015 was the highest in 'low income level'. The results were similar after adjusting for gender and age. Conclusions: For the past decade, the overall intake of kimchi in Korea has decreased, however, it has been found that the decrease of kimchi intake for males living in the rural areas was not significant. Therefore, in order to keep our traditional kimchi culture and promote a balanced diet including kimchi for Korean, it is necessary to develop more efficient policies and approaches. A variety of dishes using kimchi should be developed, besides merely serving kimchi with rice as a side dish, to increase the consumption of kimchi.

Preparation and Comparison of Proteus mirabilis and Citrobacter freundii Bacterial Electrodes for the Determination of Cytosine (Cytosine 정량을 위한 Proteus mirabilis와 Citrobacter freundii 박테리아전극의 개발과 그 비교)

  • Gwon Shik Ihn;Bong Weon Kim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.333-341
    • /
    • 1988
  • The bio-electrode for cytosine has been constructed by immobilizing Proteus mirabilis and Citrobacter freundii on an ammonia gas-sensor. Bacteria containing cytosine deaminase convert one molecule of cytosine into one molecule of ammonia. The Proteus mirabilis bacterial electrode showed linear response to cytosine concentration in the $1.0{\times}10^{-3}\;-\;5.0{\times}10^{-2}$M with a slope of 45-48 mV/decade in 0.2 M phospbate buffer solution at pH 8.4. The Citrobacter freundii bacterial electrode showed linear response to cytosine concentration in the $7.0{\times}10^{-5}\;-\;7.0{\times}10^{-3}$M with a slope of 48 mV/decade in 0.05M phosphate buffer solution at pH 7.6. These electrode were investigated for the effects of pH, temperature, buffer solutions, amounts of bacteria, interferences, inorganic salts and lifetime.

  • PDF

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (III). Continuous-Automated Determination of Nitrite Ion Using a New Tubular PVC Membrane Type of Selective Electrode Nitrate (溶解氣體 分析用 氣體感應膜 이온選擇性 電極 (第 3 報). 새로운 管形 PVC膜 질산이온 選擇性 電極을 이용한 아질산이온의連續·自動化 定量)

  • Lee Heung Lark;Yun Jong-Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.51-58
    • /
    • 1991
  • A new tubular poly(vinyl chloride) membrane type of nitrate selective electrode was prepared and its characteristics were evaluated. The response slope, detection limit, and response time (t$_{99}$) under the optimum membrane composition (5${\%}$ aliquat-NO$_3$ solution + 32${\%}$ poly(vinyl chloride) + 63${\%}$ dibutyl sebecate) of the electrode were 58.5 ${\pm}$ 0.1 mV/decade, 2.0 ${\times}$ 10$^{-5}$ M, and 25 seconds, respectively. The nitrite ion was determined by the continuous-automated method using the new electrode. 10$^{-2}$ M phosphate buffer solution (pH 7.6) was used as a recipient solution. And also hydrogen peroxide (0.3${\%}$) was added to the recipient as an oxidant. The linear response range and response range and response slope for the standard nitrite solution under the optimum condition of this electrode system were 8.0 ${\times}$ 10$^{-5}$ M ∼ 5.0 ${\times}$ 10$^{-2}$ M and 56.8 ${\pm}$ 0.2 mV/decade, respectively.

  • PDF