• 제목/요약/키워드: dc offset

검색결과 277건 처리시간 0.034초

새로운 직류 옵셋 제거 필터에 의한 정확한 페이저 추출에 관한 연구 (A Study on Accurate Phasor Extraction Using a New DC Offset Elimination Filter)

  • 박철원;윤희환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.29-36
    • /
    • 2013
  • In this paper, a new DC offset elimination filter is proposed for an accurate phasor extraction of fundamental frequency component. The proposed method can eliminate a DC offset component which is decayed exponentially. The proposed method uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. Also, the other advantages of the proposed method is that gain compensation or phase compensation is not required after filtering. Simulations using ATP were performed to evaluate the performance of the proposed filter method, and the results were compared to the ones obtained by conventional methods.

계통사고시 지수함수 형태로 감소하는 DC-Offset 성분을 계전신호에서 제거하는 Digital Filter 디자인 (Digital Filter Design for Removing Exponentially Decaying DC-Offset Component from Relaying Signal)

  • 강상희;김남호;강용철;김일동;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.59-62
    • /
    • 1992
  • Power system fault transient signals are highly distorted due to the presence of high frequency components in the voltage and current signals and an exponentially decaying dc-offset component in the current signals. Modern protective relays have to make reliable fast decisions about the nature of a fault in the presence of such transients. To use a dc-offset removing filter makes relay algorithms much fast and reliable for detecting a fault. In this paper, several dc-offset removing filters are described, and characteristics of them are compared.

  • PDF

DC-Offset 제거 기능을 향상시킨 거리계전 알고리즘 (A Distance Relaying Algorithm Using an Improved Technique for Removing DC-offset)

  • 노재근;강상희;남순열;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.118-120
    • /
    • 2001
  • This paper presents a distance relaying algorithm based on the Discrete Fourier Transform(DFT) for elimination of DC-Offset. When the DFT is applied to current signal. the real and imaginary parts of fundamental component consist of fundamental component itself and DC-Offset. The DC-Offset is calculated by four consecutive values of the imaginary components, so that the fundamental component can be accurately estimated. Performance evaluation is presented for A-phase ground faults on 154kV 80km overhead transmission line. The proposed algorithm is inspected by software simulation and hardware simulation.

  • PDF

Design of Reader Baseband Receiver Structure for Demodulating Backscattered Tag Signal in a Passive RFID Environment

  • Bae, Ji-Hoon;Choi, Won-Kyu;Park, Chan-Won;Pyo, Cheol-Sig;Kim, Kyung-Tae
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.147-158
    • /
    • 2012
  • In this paper, we present a demodulation structure suitable for a reader baseband receiver in a passive radio frequency identification (RFID) environment. In a passive RFID configuration, an undesirable DC-offset phenomenon may appear in the baseband of the reader receiver, which can severely degrade the performance of the extraction of valid information from the received tag signal. To eliminate this DC-offset phenomenon, the primary feature of the proposed demodulation structures for the received FM0 and Miller subcarrier signals is to reconstruct the signal corrupted by the DC-offset phenomenon by creating peak signals from the corrupted signal. It is shown that the proposed method can successfully detect valid data, even when the received baseband signal is distorted by the DC-offset phenomenon.

병행 2회선 송전선로의 개선된 거리계전기법 (Advanced Distance Relaying of on a Double Circuit Transmission Line)

  • 박철원
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

직접 변환수신기 (direct conversion receiver)에 적합한 DC offset이 없는 주파수 변환기를 채용한 직접변환 수신기의 설계 (Direct Conversion receiver adapting DC offset free diode mixer)

  • 박필재;유현규;조한진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.361-364
    • /
    • 2000
  • One of the problems using DCR(Direct Conversion Receiver) are DC offset, poor channel selectivity. APDP(Anti Parallel Diode Pair) can be good candidate for DCR frequency mixer due to its inherent End harmonic suppression. APDP shows good IP2 and DC suppression. This paper describe single APDP LO power characteristics, IP2, and receiver structure utilizing APDP frequency mixer

  • PDF

DC제거용 FIR필터가 거리계전기에 미치는 영향 분석 (The Influence of a FIR Filter on Distance Relaying Algorithm)

  • 오예준;장준;박진규;김수환;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2195_2196
    • /
    • 2009
  • DC-offset is a very important subject in power systems protection, since DC-offset causes mal-operation of the distance relay. This paper deals with the influence of a FIR filter used for removing the DC-offset upon the convergence characteristics of distance relaying algorithm based on Fourier Transform.

  • PDF

A New-Half Bridge Converter without DC offset of magnetizing current

  • Cho, Kyu-Min;Oh, Won-Sik;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.147-149
    • /
    • 2007
  • A new half bridge converter without DC offset of magnetizing current is proposed. The proposed half bridge converter can realize no DC offset of magnetizing current as well as no circulating current, and guarantee ZVS operation. Therefore it has high efficiency and high power density, especially in wide input range. The operational principle, DC conversion ratio and ZVS analysis are presented. Experimental results demonstrate that the proposed converter can achieve a significant improvement in the efficiency.

  • PDF

AR모델을 이용한 직류 옵셋 성분 제거 알고리즘 (A DC-Offset Elimination Algorithm Based on an AR Model)

  • 장수영;이동규;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.289-291
    • /
    • 2004
  • ln this paper, A dc-offset elimination novel algorithm based on an An model is proposed. The algorithm can eliminate dc-offset rapidly than other algorithms. The signal of fault current can be presented as a linear equation combined sinusoidal with exponential signals. Then, the linear equation can be presented an auto-regressive(AR) model and do-offset can be calculated by the equation of AR model. So it is possible to be removed the dc-offset from the original current signal. Performance evaluation of the algorithm was tested on condition that A-phase ground fault on 154kV 25km overhead transmission line.

  • PDF

듀얼 센서를 이용한 무변압기형 태양광 인버터 전류 센서의 오프셋 보정 방법 (Current Sensor Offset Calibration Method using Dual Sensor for trans-less PV Inverter)

  • 홍기남;최익;최주엽;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.182-187
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. Therefore, output current sensor measures sensing value that includes offset again. In this paper we propose new algorithm where two identical forward and reverse sensors are used to calculate the offset in real time. As a result the offset is not correlated with temperature change. The proposed algorithm is verified through PSIM simulation for validity.

  • PDF