• Title/Summary/Keyword: daylighting source

Search Result 12, Processing Time 0.02 seconds

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

Assessment of The Luminance Distribution from Daylighting window by Using Image Processing Methodology (이미지 프로세싱 기법을 활용한 채광창의 휘도분포 평가)

  • Park, Jong Myung;Lim, Hong Soo;Kim, Jeong Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.12 no.5
    • /
    • pp.77-84
    • /
    • 2012
  • Daylighting is the controlled admission of natural light into a space, reducing electric lighting and saving energy. By providing a direct link to the dynamic and perpetually evolving patterns of outdoor illumination, daylighting helps create a visually stimulating and comfort environment for building occupants, while reducing energy costs. Especially, however, glare is the most important factor in daylighting, which is issued by incoming direct sunlight into windows. This study analyzed the discomfort glare on a daylighting window by using Image processing methodology and found a solution to problems with glare source of occupants. There are several ways to evaluate discomfort glare such as UGR (Unified Glare Rating) of CIE, DGI (Daylight Glare Index, Hopkinson, 1972) and VCP (Visual Comfort Probability) of IES. These are used to apply to the relatively little artificial light source and they cannot cover discomfort glare from a real daylighting window. In this regarding, this paper aimed to calculate DGI index of the real daylighting window in a experimental space by using image processing methodology. The variables and outcomes are luminance distribution of non-shading window, effect of venetian blind installed on the window and locations related to position index of DGI.

A case study on design and construction of daylighting system of office building (사무용 건축물의 자연채광 설계 및 시공사례 연구)

  • Kim, Ilho;Choi, Yongjun;Park, Kyoungwoo;Lee, Sungjin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • Throughout history, daylight has been a primary source of lighting in buildings, supplemented originally with burned fuels and more recently with electrical energy. Before daylight was supplemented or replaced with electric light in the late 19th-century, consideration of good daylight strategies was essential. As we entered the mid-20th-century, electric light supplanted daylight in buildings in many cases. Fortunately, during the last quarter of the 20th-century and early years of this century, architects and designers have recognized the importance and value of introducing natural light into buildings. There are many simple strategies that can enhance daylighting and reduce the need for electric lights. Good quality daylight is always welcome, but remember that the electric lights must be dimmed or shut off in order for daylighting to save energy. We designed and built mirror systems and vertical daylighting devices to improve daylight condition of office buildings in bad condition because urban density is getting higher. This case study aims to analysis the principles and characteristics of mirror systems and vertical daylighting devices and selected the method that can improve constructability. The results of this study are going to use the back data to set-up the design standards. Hereafter we're going to progress the performance test and product the design manual to improve applicability of daylighting systems at design phase.

  • PDF

Development of Optical Fiber-based Daylighting System with Uniform Illumination

  • Ullah, Irfan;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.247-255
    • /
    • 2012
  • Daylighting has a very effective role in reducing power consumption and improving indoor environments in office buildings. Previously, it was not under consideration as a major source of renewable energy due to poor reliability in the design. Optical fiber as a transmission medium in the daylighting system demands uniform distribution of light to solve cost, heat, and efficiency issues. Therefore, this study focuses on the uniform distribution of sunlight through the fiber bundle and to the interior of the building. To this end, two efficient approaches for the fiber-based daylighting system are presented. The first approach consists of a parabolic mirror, and the second approach contains a Fresnel lens. Sunlight is captured, guided, and distributed through the concentrator, optical fibers, and lenses, respectively. At the capturing stage, uniform illumination solves the heat problem, which has critical importance in making the system cost-effective by introducing plastic optical fibers. The efficiency of the system is increased by collimated light, which helps to insert maximum light into the optical fibers. Furthermore, we find that the hybrid system of combining sunlight and light emitting diode light gives better illumination levels than that of traditional lighting systems. Simulation and experimental results have shown that the efficiency of the system is better than previous fiber-based daylighting systems.

A Study on the Innovation of Course Contents and Instruction of Lighting Design in Interior Design(Architecture) Education (실내.건축 디자인 교육에서 조명설계과목의 교육내용 및 방법 개선에 관한 연구)

  • 신정진;김동영
    • Korean Institute of Interior Design Journal
    • /
    • no.20
    • /
    • pp.17-25
    • /
    • 1999
  • The curriculum analysis of lighting design course in the Interior architecture departments in American universities reveals they share a major concern in the basic lighting theories, the sorts of light source and lighting equipment, daylighting, and interior lighting plav. The curriculum is usually composed of two semesters, the first semester being about lighting theory and simple project, while the second one abut more professional fields of design studio. The curriculum of lighting design at the Interior architecture departments in Korean colleges and universities usually consists of introductory courses in the field. Almost every institution allocated only one semester for the courses, and as the courses should cover the broad range within a short time, they were lacked in the required depth and systematic approach. The analysis also reveals the curriculum in Korea puts emphasis on the interior lighting equipment design, while disregarding the importance of daylighting. In comparison, American institutions have their curriculum focused upon the use of daylighting. The curriculum of lighting design courses in Korea, a major part of space rendering methods in the field of Interior Architecture, should be improved without delay. The courses should be included in the required subjects and the educational aims should be changed from offering a general understanding of the concepts to providing professional knowledge and skills, which would contribute to the competitiveness of the departments.

  • PDF

Effect of Luminance Difference on Discomfort Glare from a Large Glare Source with Non-uniform Luminance (대광원의 상하부 휘도차가 불쾌글레어 평가에 미치는 영향)

  • Kim, Wonwoo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.29-34
    • /
    • 2007
  • Discomfort glare from windows is an important issue in window and daylighting design. This study aims to investigate the effect of luminance difference between the lower and the upper part of a large glare source. Experiments were conducted using a luminous body divided into two parts, the upper part and the lower part. The degree of discomfort glare from the luminous body was examined. The result shows that the part with lower luminance is perceived as a glare source when the part has higher luminance then the background luminance. The degree of discomfort glare was estimated for the experimental conditions, and compared to the observations. The estimation was made using two methods: one summed the glare sensation for each section, and the other used the average luminance of the whole luminous body. The result of the comparison shows that the method using the average luminance has approximate values to the observations. Consequently, the use of the average luminance was proposed for evaluation of discomfort glare from non-uniform large glare sources.

An Experiment of Discomfort Glare from Non-uniform Glare Source (불균일한 휘도를 갖는 창면의 불쾌글레어 평가실험)

  • Shin, Ju-Young;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • Impact of daylighting on the visual environment can improve occupant's well-being by providing visual comfort. Also, daylighting can save energy. However, glare from window can be a direct hazard to vision and can cause serious discomfort. Selecting glare source on a window plane is very important for evaluating discomfort glare from windows. But former glare indices can not identify the range of the glare source properly. In this study, difference in glare sensation with uniform and non-uniform glare sources are evaluated to identify the range of the glare source. The glare source was assumed as $120{\times}120[cm]$ window model. The window was divided into three parts with different luminance values. The experiment was conducted under 1[m], 1.5[m], 3[m] distance from the glare source. Two results were obtained from the experiments. First, the degree of discomfort glare increased as average window luminance increased. Second, the middle and lower part of the window plane can affect evaluation of discomfort glare as well as the upper part of the window plan. These results can be used for selecting the glare source in a window with non-uniform luminance.

The Role of Reflected Sunlight in Daylighted Office Environment (사무공간의 자연채광에 있어 반사광의 효용성에 관한 연구)

  • Kim, Gon
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.35-43
    • /
    • 1997
  • An increase in the design of commercial buildings with daylighting is beginning to receive more attention, claimed by some as a second revolution in architecture. The benefits of daylighting may vary significantly because a characteristic of daylight is the way in which it varies. Indirect sunlight, however, received in the interior of a building after reflection, can serve a useful purpose as the main source of illumination. In a cloudy climate it can serve as an occasional welcome addition to the available skylight. Also, site constraints or surrounding urban context may necessitate using reflected light sources, or such sources may be an integral part of the overall design objectives and aesthetics of the proposed projects. When reflected sunlight is introduced into a space, its role in general illumination is what is of interest in this study. Results show that reflected sunlight may help the general illumination in almost same level of significance as daylight from diffuse sky. It is also summarized that the contribution of reflected sunlight to general illumination through the year round may be even and uniform regardless of the season. Consequently, introduction of reflected sunlight should be regarded as one of the successful means to enhance the visual environment in quantitative and qualitative way.

  • PDF

A Study on the Daylighting Transmittance Efficacies of Skylights by Calculating the Effective Transmittance of Light Well (광정의 유효투과율에 의한 천창 형태별 주광의 투과효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • Daylight is one of the most critical factors that can be utilized for architectural spaces; compared to artificial light, it is a sustainable energy source without the cost of electric energy and offers a more natural feeling to the visitors in the building. To make the space quality better, many architects have tried to predict daylight performance during the design process. The aim of this study is to evaluate the daylight transmittance efficacies of the five shapes - Flat, Pyramid, Dome, Barrel Vault. Ridge - of skylights. The results of this study indicated that the differences of transmittance efficiency among various skylights were less than 4.6% except the flat shaped skylight. Therefore, this study shows that there were no big differences of the daylight transmittance efficacies among the shapes of skylights.

An Approach to the Theoretical Design Standard and Effective Practice of Museum Showcase Lighting (진열장 조명의 이론적 기준과 시설에 대한 고찰)

  • Kim, Hong-Bum
    • 보존과학연구
    • /
    • s.17
    • /
    • pp.123-160
    • /
    • 1996
  • There have been many studies and experiments regarding exhibition lighting. Many experiments on photochemical damaging effect and visibility resulted in a practice limited to assigning light levels and adjusting annual exposure time. The three damaging factors to the artifacts are intrinsicsusceptibility to absorb radiant energy, spectral distribution of light source and intensity of illumination and time of exposure. Dividing all the artfacts into three categories to suggest a recommended illuminance level causes some problems. Blue wool, for example, used as the reference material for susceptibility, is not a standard material representing museum artifacts. In the most light sensitive category, ISO class I or anything below have been excluded. The exposure time of one soure can be three times more than another sourece. The spectral distribution of the light source and the relative spectral responsibility of the artifact are not considered in the practice. So in case of very light sensitive material, the recommended illuminance is only the referring value and it is indispensable to check the characteristic of susceptibility of each artifacts. Daylighting is prevailing method to solve the psychological need of the visitors. However, it sould transparent, and should not diffused, and the green-house effect must be considered. llluminance uniformity should based on the maximum illuminance to handle the limitation of exposure for the conservation of a large sensitive object such as a painting. Damage index is not absolute reference for selecting the lighting source because it is experimented from the paper of low grade then calculated. Visibility should be increased by reducing the visual noiseand by planning of appropriate luminance contrast. This paper reviews the problems with the previous studies and experiment sand the current exhibition lighting design practice. The plan for museum showcase lighting is to check the susceptibility and to raise the visibility simultaneously.

  • PDF