• 제목/요약/키워드: daylighting analysis

검색결과 65건 처리시간 0.021초

최신 자연채광 디자인 사례들 분석 및 그 적용에 관한 연구 - 미국 LEED 인증 공동주택 사례분석을 바탕으로 - (Study on the Analysis and the Application of State-of-the-Art Daylighting Design Cases - Based on the Case Studies of LEED(Leadership in Energy and Environmental Design) Multi-Family housing -)

  • 윤혜경
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.265-273
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art daylighting design among LEED(Leadership in Energy and Environmental Design) multi-family housing cases and to explore the feasibilities for their applications in domestic housing design. Occupants in multi-family houses are reported to consume more electricity power than those in single houses. That may imply the problems of daylighting design in domestic housing design for multi-family houses have better insulation system and less windows and outside walls than single houses. Therefore two systems, daylight delivery system and daylight control system, are scrutinized for daylighting design with LEED cases. The findings show when windows as a daylight delivery system are combined with overhangs, fins, louvers, fenestration materials, speciality fenestration, or interior controls as a daylight control system, the outcome goes with more energy savings and better facade design. Beside those, lightshelves as a daylight delivery system seem to have potentials in domestic multi-family houses with deep plans and less outside walls. Daylighting designs in domestic multi-family houses need to pursue available options more to achieve the integration of energy and aesthetics values.

대학강의실 전면현휘 감소를 위한 주간채광유입 시뮬레이션에 관한 연구 (A Study on Simulation of Daylight for Reducing Glare of the Lecture Room's Front Side in University)

  • 정지석
    • 한국주거학회논문집
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2013
  • The University students learn their major or a general education in lecture rooms. In these days, lecturer use frequently various multimedia in lecture room. Appropriate control lighting environment in lecture room should be essential and related in efficient studying. Daylighting on front-side of lecture room will cause glare and students are hard to read contents on white-board at their seat. Therefore, in order to preventing glare we simulated daylighting of lecture room with using computer software in this study. Results from simulation and analysis as follows: The first, if students' left-side is east-oriented in lecture room, best daylighting condition about glare in lecture room. The second, architectural designers can use simulation data of daylighting or simulate data in designing university buildings with lecture rooms. Finally, if reducing size of windows (narrow and deep daylight: more closing vertically, from up to down daylighting: more closing horizontally) we will be able to reduce energy from lecture room.

Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험 (Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment)

  • 김정태;신화영
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

조명 소프트웨어를 이용한 추적식 디쉬형 집광기의 배광분포 분석 및 자연채광 성능 예측 (Analysis on Candela Distribution Curve of a Tracking Dish Concentrator and Daylighting Prediction using Lighting Programs)

  • 오승진;한현주;신상웅;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.457-462
    • /
    • 2012
  • Daylighting software is an important component to predict the performance of daylighting system in advance of a field demonstration study with installing them in buildings. PHOTOPIA is a powerful software to generate a candela distribution curve(CDC) of an active daylighting system like a tracking dish concentrator. With PHOTOPIA, a set of candela distribution curves was generated under clear sky conditions and different solar altitude angles. The candela distribution curves were then imported to RADIANCE for rendering and analysis on the daylighting performance of a tracking dish concentrator when it installed in a actual class room without windows. As a result, the daylight collection efficiency of the dish concentrator was 68.4% when we assumed that there was no tracking error. It was found that candela(cd) and total lumens(lm) increased with solar altitude rising, whereas the distribution angle was fixed. The illuminance uniformity on the work plane in the class room was relatively low, 0.12, while the illuminance uniformity on the area of $2.7m^2$ to which the light was illuminated was considerably high, 0.60. The maximum illuminance was 1,340lux with a solar altitude angle of 80 degrees.

  • PDF

집광채광시스템을 적용한 실내체육관의 신재생에너지 공급의무 분담률에 관한 연구 (A Study on the Supply obligations allotment rate of New Renewable Energy in Indoor Gymnasiums with the Application of a Daylighting System)

  • 박윤하;이용호;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.27-39
    • /
    • 2015
  • Under the goal of analyzing the compulsory supply share of new renewable energy according to the application of a daylighting system to indoor gymnasiums, this study conducted analysis of energy consumption and operation schedule at three indoor gymnasiums in the nation through a survey. The investigator did an Energy Plus simulation on Building A based on the analysis results and analyzed the supply share of new renewable energy in the saving effects of lighting energy according to the application of a daylighting system. As a result, When 92 prism daylighting system were installed in the upper ceiling of a stadium, they were able to meet the criteria for the minimum illumination for official games(Min : 600㏓) and optimum illumination for general games and recreations, thus saving lighting energy during the daytime(09:00~17:00). The resulting saving effects of lighting energy amounted to 44.4% for official games, 57.6% for general games, and 66.7% for recreations. In addition, the daylighting systems had a compulsory supply share of new renewable energy at 2.04% for official games, 2.75% for general games, and 2.62% for recreations, recording an average compulsory supply share of 2.5%.

자연광 분석을 통한 LED조명색채 개발 방향 (A Study on direction of LED Lighting Color development through analysis of the Daylighting)

  • 양정순;이미연
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.9-19
    • /
    • 2012
  • The purpose of this study is to present the direction of LED lighting development to give people a comfortable feeling. For about 2 years, the database of daylighting color has been built by daylighting measurement and analysing hourly, monthly and seasonal change in daylighting colors. Finally, changes of color coordinates were drawn as a graph and it presented as the LED lighting color development indicator through the relationship with Plankian locus. This methodology is expected to contribute to the development fields of the LED lighting color.

Lightscape를 이용한 광선반의 시뮬레이션 평가 연구 (A Study on the Computer Simulation Estimate of Light Shelf Using Lightscape)

  • 조일식;김기세;윤종호;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.93-102
    • /
    • 2003
  • One of the promising optical daylighting systems is light shelf type daylighting system, Two types of lighting performance analysis methods are 1) Ray-Tracing method and 2) Radiosity method. The purpose of this paper is to compare two methods in terms of advantages and disadvantages by further looking at the detail algorithm. Also. model verification with Lightscape simulations has been conducted. Effectiveness of light penetration factor in terms of daylighting factor has been investigated and quantified. In summer time. the performance of the light shelf was twice better than the case without it.

실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석 (Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model)

  • 백승헌;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

LCC 기법을 통한 자연채광의 경제성 분석에 대한 연구 (A Feasibility Study on the Benefit of Daylighting by LCC Analysis)

  • 김정태;김곤
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.3-10
    • /
    • 2006
  • As has been expected, economic factors are a major consideration in almost every decision in building design process. Assuming that improving a lighting system, existing or proposed, will reduce operating cost, what preliminary economic guidelines can be established to determine whether any proposed investment appears cost effective? In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. This paper aims to exemplify the benefit of daylighting in term of economic consideration. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The accumulated performance of electric and daylighting is figured out to declare the effective depth of daylight in the space. The analysis on the saving amount of lighting energy due to daylight has been undertaken in answer to the question, that is, several projects are being considered, which is the most desirable from the cost-effectiveness viewpoint. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control hardware.

공동주택의 공간별 채광실태에 관한 연구 (An Analysis of Daylighting in Each Space of Apartment Houses)

  • 황민구;신혜미
    • KIEAE Journal
    • /
    • 제8권4호
    • /
    • pp.43-48
    • /
    • 2008
  • One of the most important factors in determining the quality of living environment is daylighting. Especially its influence in the psychological and biological life of human beings cannot be underestimated. Therefore, lots of researches have been given to develop a more efficient daylighting system. The sunlighting system, one of many developed systems, has been developed and applied in various ways. However, the high cost of sunlighting system has been the most difficult stumbling-block in making it commercial. However, as domestic apartment houses tend to be more luxury, life environment becomes a very important factor more than cost in building apartment house. Therefore, it would be possible to adopt sunlighting system in the non-window areas such as a restroom in an apartment house. This research is a preliminary work in order to measure a possibility of applying sunlighting system in an apartment house. In order to do so, I measure Sunlight Illuminance Ratio in various areas of apartment house. As a result, in case of a residential-commercial building, areas such as kitchen, restroom, and entrance are relatively weak-lighting areas. In case of a traditional apartment house, restroom and entrance are relatively weak-lighting areas. For that reason, a special lighting support is needed in these areas.