베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구 (Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind)

  • 김철호;김강수
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

지구 저궤도 위성의 영상임무 자세에 따른 열적 영향 고찰 (Investigation on Thermal Effect for a Low Earth Orbit Satellite during Imaging Maneuvering)

  • 김희경;이장준;현범석
    • 한국항공우주학회지
    • /
    • 제36권12호
    • /
    • pp.1216-1221
    • /
    • 2008
  • 본 논문에서 고려된 저궤도 위성은 고정형 태양 전지판을 가지기 때문에 낮구간(daylight) 동안에 태양전지판이 태양지향(sun-pointing) 자세를 유지하고, 관측 임무 수행을 위해 태양 전지판 방향과 반대방향에 위치한 탑재체가 지구지향(nadir-pointing)이 되도록 자세를 변경한다. 이 때 낮기간의 대부분을 차지하는 태양지향 자세에서는 위성 패널(panel)로 입사하는 외부 열환경 요인이 지구 복사열과 알비도(Albedo)이기 때문에, 비교적 안정적인 열환경 조건을 가지고 있다. 이에 반하여, 관측 임무를 수행하는 궤도 10% 정도의 지구지향 자세에서는 위성의 열환경 조건에 가장 지배적인 영향을 주는 태양광이 위성 패널에 영향을 준다. 비록 위성이 비교적 짧은 시간 동안에 지구 지향의 자세를 유지하지만, 이러한 열한경 조건의 변화 때문에 위성의 열설계에서 지구지향의 임무 자세에 따른 열적 영향에 대한 검토가 필요하다. 본 연구에서는 열해석 모델에 관측 임무 구간 동안의 지구지향 자세를 반영한 열해석 결과를 통하여 그 영향을 알아보았다.

다색 광원에 대한 가우시안 진폭을 갖는 광학계의 결상 특성 (The Image-forming Property of Optical System having Gaussian Amplitude for Polychromatic Source)

  • 박성종;박혜정
    • 한국안광학회지
    • /
    • 제4권2호
    • /
    • pp.33-38
    • /
    • 1999
  • 다색 광원에 대한 가우시안 진폭을 갖는 광학계의 결상 특성을 조사하기 위하여 다색 광원에 대한 결상 광학계의 색도(chromaticity) 변화와 조도(illuminance) 분포를 계산하였다. 본 논문에서 고려된 다색 광원은 색온도 2,856K인 텅스텐 백열 램프(incandescent-tungsten lamp)를 나타내는 A광원, 대낮의 평균 햇빛(daylight)을 나타내는 C광원, 대낮의 평균 햇빛의 파장영역을 자외선 영역까지 확대하여 보강한 $D_{65}$광원이다. 다색 광원들의 종류에 따라 기하학적 상점에서의 색도 값이 다르게 나타났으며, 기존의 균일한 진폭을 갖는 광학계에 비해 색도 변화가 매우 작게 나타났다. 조도 분포는 다색 광원의 종류에 따라 거의 변화가 없었으며, 초점 심도는 기존의 균일한 진폭을 갖는 광학계에 비해 크게 나타났다. 이러한 결과로부터 결상 광학계에 입사하는 광의 진폭 형태를 균일한 진폭에서 가우시안 형태로 변조시켜줌으로써 초점 심도는 크게, 색도 변화는 작게 할 수 있다.

  • PDF

초등학교 채광 성능 실태조사에 따른 건축계획적 개선방안에 관한 연구 (Architectural Implementation for the Daylight-Performance in the Elementary School)

  • 이정철;임홍수;김곤;구재오
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.43-50
    • /
    • 2010
  • Natural lighting is directly connected with our mental and physical health. For working or learning effect, the proper natural lighting is required for improving our living conditions. School facilities, especially, are the place where includes students' ordinary activities with learning behaviors during the school years from elementary to high school. This study was carried out for the purpose introducing a basic database in that planning a school by researching on the actual in the natural lighting system of some schools' classroom, estimating, and analyzing through a simulation, which resulted in a method of improving the natural lighting system. As a result of measuring and analyzing Daylight Factor(DF) during the time from 9 am to 3 pm when students are activating in their classroom, generally DF range of the sides near to window and aisle seats zone are not distributed well. Besides, two out of four school which are researched would not reach the standards of the law for school sanitary while rest of the schools meet the standards; Average DF 5% and Minimum DF 2%. And the result of a simulation by RADIANCE program shows the most appropriate DF range when it is applied in variable numbers about an oriehows the- South-east 15, south-east 30, south-east 45, south-west 15, south-west 30, and south-west 45 degrees. When it is applied in the variable numbers about glass transmittance - 60%, 70%, and 80% in condition facing south of a classroom, the result shows that the DF range of 80% transmittance is relatively higher than other glasses in the classroom. Thus, when a school is built, plans for an orientation is necessary for improve of elementary schools' environment with the glass installation which is made for high transmittance and is regarded with the students' activities time.

주간 활용 별센서의 별 감지가능성 분석 (Star Detectability Analysis of Daytime Star Sensor)

  • 나자경;이유;김용하
    • 한국항공우주학회지
    • /
    • 제33권9호
    • /
    • pp.89-96
    • /
    • 2005
  • 이 논문에서는 주간 항법용 별센서의 실제 활용을 목적으로 주간 대기 조건과 주간 별 감지 가능성을 논한다. 주간동안의 대기 자료를 구하기 위해 표준 대기 모델(LOWTRAN 7)을 사용했으며 그 모델로부터 배경하늘에 대한 복사와 대기투과도를 구하였다. 대기 복사량을 감소시키기 위해 광학 필터를 장착한 별센서를 가정했으며 태양 복사 효과를 나타내기 위해 별센서와 태양 사이의 다양한 분리각을 설정하였다. 별센서의 FOV에 대한 고려로서, 하늘 배경 복사의 변화와 감지가능한 별의 개수 밀도를 분석하였다. 또한 요구되는 신호 대 잡음비를 얻기 위한 노출시간과 별센서의 주간 활용 한계로서 작용하는 CCD의 복사에 의한 전자 수를 계산하였다.

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석 (Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles)

  • 신화영;김곤;김정태
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.