• Title/Summary/Keyword: data-acquisition system

Search Result 2,083, Processing Time 0.032 seconds

Brake Noise Data Acquisition and Analysis System

  • Vadari, Vish;Niezgoski, John;Edgar, Dave;Elliot, Dan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.505-508
    • /
    • 2002
  • AN EMBEDDED PC-BASED HARDWARE AND SOFTWARE SYSTEM HAS BEEN DEVELOPED TO AUTOMATE THE DATA ACQUISITION AND ANALYSIS OF BRAKE SQUEAL. THE DEVELOPED SYSTEM INTEGRATES ADVANCED SIGNAL CONDITIONING HARDWARE AND SOFTWARE TO ACQUIRE BRAKE NOISE AND VIBRATION DATA RAPIDLY, CONSISTENTLY AND OBJECTIVELY. A SPECIAL PEAK-PICKING ALGORITHM IS USED TO DETERMINE WHEN BRAKE NOISE OCCURS DURING A STOP EVENT AND ACTUALLY DEFINE FROM WHICH CORNER OF THE VEHICLE IT ORIGINATES. A SPECIAL NOISE-RATING TABLE IS FEATURED TO ENABLE THE USER TO DEVELOP CORRELATIONS BETWEEN DRIVER RATINGS AND OBJECTIVE MEASUREMENTS.

  • PDF

A Study on Developing the Acquisition Unit Cost Estimating Model of the Guided Weapon System (유도무기 획득단가 추정 모델 개발에 관한 연구)

  • Kim, Yonghyun;Lee, Yongbok;Jung, Wonil;Kim, Dongkyu;Kang, Sungjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.565-576
    • /
    • 2012
  • Cost estimates are necessary for government acquisition program to support decisions about funding, to develop annual budget requests and to validate resource requirements at key decision points. Many researches have been done about cost estimating technique recently. Parametric cost estimating models based on CERs(Cost Estimating Relationships) have been mainly used using regression method with historical data. However, there are many restrictions in developing Korean version CERs because the number of data points are too small. Specially, data collection and data management system are unstable in Korean defense environment, when developing CERs. In this research, we analyzed the historical data, and found some cost drivers in guided weapon system area. We developed the Acquisition Unit Cost CER using the regression to remove multicollinearity in the historical data. So we could overcome the restriction of the insufficient sample number. This research as a first attempt is meaningful in terms of obtaining our own Acquisition Unit Cost CER using historical cost and physical characteristic in Korean development environment.

SE Case Study in Eagle Acquisition Program (독수리구매사업 시스템엔지니어링 적용사례)

  • Lee, Hi-Jang;Lee, Dong-Seok;Ham, Hyuck-Sang;Rho, Kyun-Hyup;Kwon, Young-Hoon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.9-16
    • /
    • 2007
  • To Manage the Defense Acquisition Process more efficiently, DAPA has looked over the applying SE process to the Eagle Acquisition Program. Based on comparing 'Requirement' with 'items suggested in the proposal' in RFP and analyzing the result by using Cradle, those items have been discovered with IPT, actualized and corrected. In addition, the computerized data base system makes easier to trace all changed and more efficiency to manage programs. Therefore, this study using SE in other acquisition program.

  • PDF

Composition of effective monitoring system using an interpolation (보간법을 이용한 효율적인 모니터링 시스템 구성)

  • Lee, Sang-Hyeok;Kang, Feel-Soon;Jung, Da-Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.235-238
    • /
    • 2007
  • This paper presents an efficient data storage and reconstruction method in data acquisition and processing of monitoring system. The proposed method extracts minimum data using an interpolation from raw data which are acquired from a target system. The algorithm for data acquisition and reconstruction is based on Cubic Hermite interpolation. To verify the validity of the proposed scheme, we presents simulation results and it is applied to a monitoring system for grid-connected photovoltaic power generation system to prove the high-performance of the proposed method.

  • PDF

Development and application of construction monitoring system for Shanghai Tower

  • Li, Han;Zhang, Qi-Lin;Yang, Bin;Lu, Jia;Hu, Jia
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1019-1039
    • /
    • 2015
  • Shanghai Tower is a composite structure building with a height of 632 m. In order to verify the structural properties and behaviors in construction and operation, a structural health monitoring project was conducted by Tongji University. The monitoring system includes sensor system, data acquisition system and a monitoring software system. Focusing on the health monitoring in construction, this paper introduced the monitoring parameters in construction, the data acquisition strategy and an integration structural health monitoring (SHM) software. The integration software - Structural Monitoring/ Analysis/ Evaluation System (SMAE) is designed based on integration and modular design idea, which includes on-line data acquisition, finite elements and dynamic property analysis functions. With the integration and modular design idea, this SHM system can realize the data exchange and results comparison from on-site monitoring and FEM effectively. The analysis of the monitoring data collected during the process of construction shows that the system works stably, realize data acquirement and analysis effectively, and also provides measured basis for understanding the structural state of the construction. Meanwhile, references are provided for the future automates construction monitoring and implementation of high-rise building structures.

Development of a Practical Field Data Acquisition Device for Civil and Environmental Engineering Applications (토목환경공학분야의 응용을 위한 실용적인 현장자료수집기의 개발)

  • 여운광;윤병만;이종국;허정호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.9 no.4
    • /
    • pp.176-181
    • /
    • 1997
  • A practical, easy-to-use data acquisition device has been developed for use in civil and envirionmental engineering applications. It uses the PC parallel port for the acquisition and data transfer and is simple enough to be setup and run in laboratory and field experiment conditions. The usual limitations of data storage capacity of several data loggers was solved by using PC resources. Also versatile programming capability using high level languages of the PC programming environment such as C and Visual Basic enables the data acquisition device to be configured as a general and practical data acquisition system. An example of effective uses of the device is. provided for the water environment measurement at the Bangwha bridge construction site. The in site. test proved the device to be practical in civil and environmental engineering applications.

  • PDF

Multi-Channel Data Acquisition System Design for Spiral CT Application

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yun Yi;Kwak, Sung-Woo;Cho, Kyu-Sung;Park, Jung-Byung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.468-470
    • /
    • 2002
  • We have designed X-ray detection system and multi-channel data acquisition system for Spiral CT application. X-ray detection system consists of scintillator and photodiode. Scintillator converts X-ray into visible light. Photodiode converts visible light into electrical signal. The multi-channel data acquisition system consists of analog, digital, master and backplane board. Analog board detects electrical signal and amplifies signal by 140dB. Digital board consists of MUX(Multiplex) which routes multi-channel analog signal to preamplifier, and ADC(Analog to Digital Converter) which converts analog signal into digital signal. Master board supplies the synchronized clock and transmits the digital data to image reconstructor. Backplane provides electrical power, analog output and clock signal. The system converts the projected X-ray signal over the detector array with large gain, samples the data in each channel sequentially, and the sampled data are transmitted to host computer in a given time frame. To meet the timing limitation, this system is very flexible since it is implemented by FPGA(Field Programmable Gate Array). This system must have a high-speed operation with low noise and high SNR(signal to noise ratio), wide dynamic range to get a high resolution image.

  • PDF