• 제목/요약/키워드: data-acquisition system

검색결과 2,078건 처리시간 0.032초

엔진 성능(性能) 시험용(試験用) 데이터 수집(蒐集) 시스템에 관한 연구(硏究) (Microcomputer-Based Data Acquisition System for Engine Performance Test)

  • 임순재;류관희;박보순
    • Journal of Biosystems Engineering
    • /
    • 제11권1호
    • /
    • pp.8-16
    • /
    • 1986
  • This study was carried out to develop a microcomputer-based data acquisition system for engine performance test. A low-cost data acquisition system was developed utilizing an "APPLE II PLUS" microcomputer. The developed system consists of microcomputer, RPM counter included frequency-to-voltage converter, preamplifier for two load cells and 8-bit analog-to-digital converter with 16 chnnels. The system simultaneously measures engine speed by means of photointerrupter, torque and fuel consumption by means of load cells with variable sample numbers, sampling intervals and repetitions. The system collects, processes and provides data for storing on the $4{\frac{1}{4}}$ inch floppy disk as well as for writing out on the printer.

  • PDF

광대역 낙뢰신호 탐지 및 획득 시스템 개발 (Development of a Detect-and-Acquisition System for Broadband Lightning Signals)

  • 송승헌;김동혁;이성호;우정욱;성태경
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1503-1510
    • /
    • 2007
  • To implement a high-precision lightning tracking system utilizing TDOA measurements, high-speed data acquisition and precise timing synchronization between ground sensors should be achieved. At the same time, considering the size of digitizer's memory, the data memory needs to be managed so that only the sampled data around the occurrence of stepped leader pulse is stored. This paper presents a detection-and-acquisition system for lightning signals that is the main equipment of ground sensor in lightning tracking system. GPS clock module is used to get precise timing synchronization and the 500MHz high speed digitizer is employed. In order to detect the leading edge of the lightning pulse and save the sampled data and its timing, lightning detection module is implemented and multi-record method is employed in the proposed system. Field experiment results show that the proposed system can detect and save the lightning signal efficiently.

3차원 모션 데이터 획득의 성능 향상을 위한 연구 (The study of improving the accuracy in the 3D data acquisition)

  • 한창호;오춘석;유영기
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권5호
    • /
    • pp.205-210
    • /
    • 2008
  • 기존 논문에서 CCD 카메라를 이용해 3차원 데이터를 획득하는 시스템을 소개했었다. 하지만, 정확도에서는 기존에 개발한 다른 PSD 카메라를 이용한 시스템과 큰 차이를 보이지 않았다. 본 논문에서는 2대의 카메라로 스테레오 기법을 이용하여 3차원 데이터를 획득하는 시스템을 소개하며, 두 카메라의 캘리브레이션에 대해 살펴보며, 3차원 데이터를 획득하는 방법을 소개한다. 3차원 획득의 정확도를 개선하기 위해 여러 가지 방법을 제안과 설험을 했으며, 결과를 통해 상당히 향상되었음을 알 수 있다. 제안된 방법은 왜곡제거, z축 보정 등이며, 각 방법의 비교실험을 통해 얼마나 개선되었는지 살펴본다.

  • PDF

효율적인 실시간 데이터 수집시스템의 설계 (Design of an effective real-time data acquisition system)

  • 김동욱;염재명;김대원;박용식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1036-1039
    • /
    • 1996
  • The performance of real-time systems depends upon how well the tasks are scheduled within a cycle time and how fastly the response is made according to the occurrence of an external event. This paper presents the design of an effective real-time data acquisition system in order to gather the data from an automobile engine. This paper investigates an estimation and a restriction method of execution for aperiodic data. Also, the guarantee problem of real-time constraint is presented for periodic data. Through the experiments, the hard real-time guarantee problem of periodic data is studied and the damage problem of periodic data according to the increase of aperiodic tasks is analyzed.

  • PDF

3kW급 계통연계형 태양광발전시스템의 성능 비교분석 (Performance Analysis of 3kW Grid-Connected PV System)

  • 소정훈;정영석;유권종;이기옥;최주엽;안현식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.707-710
    • /
    • 2003
  • 3kW grid-connected photovoltaic (PV) system and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV system have simulated and evaluated using simulation tool in comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of total PV system e.g. electric power and loss factor at the site are reviewed.

  • PDF

비 강압적 3차원 얼굴 데이터 획득 시스템 연구 (Non-intrusive 3D Face Data Acquisition System)

  • 김중락;유선진;임경민;김수연;이상윤
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.929-930
    • /
    • 2008
  • To develop reliable 3D face recognition system, many researchers also have focused on 3D face data acquisition system. Previous many 3D face acquisition systems use visible patterns to solve corresponding problem, and this pattern made anyone who wants to be verified uncomfortable. In this paper, we propose a new invisible infrared line-laser pattern for 3D face data acquisition.

  • PDF

2.4M X-BAND ACQUISITION TESTS WITH KOMPSAT-2

  • Koo, In-Hoi;Park, Chun-Woo;Yang, Hyung-Mo;Ahn, Sang-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.512-514
    • /
    • 2007
  • Even though official G/T for KOMPSAT-2 X-Band downlink acquisition was 32dB/K, KARI performed the data acquisition experiment using 2Am X-Band antenna to check if popular 2Am MODIS receiving antenna can receive KOMPSAT-2 MSC data within acceptable quality level. Through several acquisition tests, it was shown that G/T value of 24dB/K can provide the reliable data BER quality, 10-6 for the above the elevation angle of 10 degree. Some plots for Eb/No versus elevation angle are provided.

  • PDF

인터넷 기반 실시간 원격 고속가공 모니터링 (Internet-based Real-Time Remote Monitoring System for High-Speed Machining Process)

  • 이우영;최성주;김흥배
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.952-955
    • /
    • 2000
  • Nowadays, Internet is so popular that we can easily access the remote site to search information and to communicate remote site and users. People who want to make a collaborate working environment can use JAVA, CORBA, and other internet programming tools like a Perl/XML. The mechanist are try to make the environment fur collaboration within design/manufacturing, simulation, remote sensing through TCP/IP And many industries and research institutions are working towards the agile manufacturing. This paper describes an internet-based real-Time remote monitoring system. The system consists of a hardware setup and a software interface. The hardware setup consists of a machine and its data acquisition hardware, while the software interface incorporates the data acquisition software, the server program, and the client program. The server program acts as the main interface between the data acquisition system and the internet technology. The client program is to be distributed to the remote users who want to monitor the machining status. The system has been demonstrated and verified for an industrial High-Speed Machine (HSM) especially measuring cutting force and acoustic emission. To share the signal, we make the WWW server and display its value. The system has been found to be highly efficient, reliable and accurate.

  • PDF

AMI 적용 스마트 미터 기능향상을 위한 개별부하 상세 데이터 무선 취득장치 개발 (Development of Wireless Data Acquisition Device for Individual Load to Improve Function of Smart Meter Applied to AMI)

  • 성병철;배선호;박우재;전승욱;박정욱
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1795-1803
    • /
    • 2011
  • Advanced Metering Infrastructure (AMI) is one of the important components to form a smart-gird, which is an advanced power system by combining the power system with the communication systems. This AMI makes it possible to exchange information between operators and consumers for the efficient and reliable operation of the power system through a smart meter or a In-Home Display. However, according to the increase of the demanded information such as the power quality, the accurate load-profile, and the billing data to help customers manage their power consumption, it is necessary to gather more accurate analytical data from each house appliances and transfer it to the smart meter for synthesizing the information and controlling each loads. In this paper, the development of the wireless data acquisition device for the individual load data metering, which is connected with the smart meter for advanced functions, is proposed. AVR, a kind of microcontroller, and Bluetooth are used and integrated into the proposed the wireless data acquisition device to transmit the detailed power data (voltage and current) to the smart meter. To verify the effectiveness of the proposed system, a hardware experiment is carried out including the confirmation of the possibility for providing the more various information by applying analysis algorithms to the obtained data. Also, the application structure of the wireless data acquisition device to gather the data from the various house appliances is presented.

유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안 (The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data)

  • 김윤하;최현주
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.