• Title/Summary/Keyword: data analysis-solar system

Search Result 376, Processing Time 0.027 seconds

Calculating the Sunlight Amount for Buildings Using SAS: A Case Study of Gyeongsan City (그림자 분석 시뮬레이션을 활용한 건축물별 일조량 산정 - 경산시를 사례로)

  • Kim, Do-Ryeong;Kim, Sung-Jae;Han, Soo-Hee;Jo, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.1
    • /
    • pp.159-172
    • /
    • 2014
  • As greenhouse gas emissions have been increasing in the world, global warming is being recognized as a cause of the global problems like climate change. This is closely associated the fossil fuels. Thus renewable energy has been brought to the attention of many people as the upcoming alternative energy source to cope with the fossil drain and increased environmental regulations. Especially, the solar energy among renewable energy has drastically increased. In this study, we calculate on daylight ratio about the solar energy for buildings based on digital surface model. The digital surface model was made using the spatial information data. And it was simulated the shadow analysis using SAS. Therefore, it was suitable places to utilize the solar energy in the Gyeongsan city. Consequently, the daylight ratio was considered important factor to select region of the industry of the solar light power generation.

Analysis of Surplus Solar Energy in Greenhouse Based on Setting Temperature (설정온도별 온실내 잉여 태양에너지 분석)

  • Yoon, Yong-Cheol;Kown, Sun-Ju;Kim, Hyeon-Tae;kim, Young-Joo;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.195-206
    • /
    • 2012
  • This study is about an analysis of surplus solar energy by important greenhouse types as well as setting temperature different by using Typical Meteorological Year data which was secured in order to provide basic data for designing an optimum thermal storage system to accumulate surplus solar energy generating in greenhouses during the daytime. Depending on the setting temperatures of $15{\sim}19^{\circ}C$ for greenhouse heating during day and night, surplus heat amounts were varied at the rate of about $0.2{\sim}6.9%/4^{\circ}C$ with some variations according to the greenhouse types and regions. On the other hand, the variations of supplemental heat requirements were about $29.7{\sim}50.0%/4^{\circ}C$. Depending on the setting temperatures for greenhouse ventilations(low $25{\sim}29^{\circ}C$ and high $27{\sim}31^{\circ}C$), surplus heat amounts were varied at the rate of about $-9.9{\sim}-35.6%/4^{\circ}C$ in auto-type greenhouse. But in single-type greenhouses, they were about $-5.1{\sim}-13.4%/4^{\circ}C$. There were not significant changes in supplemental heat amounts depending on setting temperatures of ventilation for both greenhouse types and regions.

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Analysis of the Status of Safety Management of Photovoltaic Power Generation Facilities (태양광발전설비 안전관리 현황 분석)

  • Kim, Wan-su;Park, Sang-June;An, Seong-ryeol
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.38-45
    • /
    • 2019
  • In this paper, we analyzed the present status of the safety manager and safety assurance aspects through a complex analysis on the operational aspects, marketability and electrical safety aspects of photovoltaic power generation facilities. In the analysis of the equipment status, we analyzed the status and operated status of the installed PV system in Korea and the correlation between the safety manager and the accident. In addition, we analyzed the direction of the ESS through the analysis of the installation status of the ESS, and applied it to the interpretation part of the ESS associated with the solar power generation. The status of the electric safety manager can be used to analyze the data for selecting the electric safety manager by capacity by analyzing the accident status, the electric safety manager operation status, the safety management time by capacity, and the electric safety manager market.

Simulated Radiances of the OSMI over the Oceans

  • Lim, Hyo-Suk;Kim, Yong-Seung;Lee, Dong-Han
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.43-48
    • /
    • 1998
  • Prior to launch, simulated radiances of the Ocean Scanning Multispectral Imager (OSMI) will be very useful to guess the real imagery of OSMI and to check the data processing system for OSMI. The data processing system for OSMI which is one sensor of Korea Mult i - Purpose Satellite (KOMPSAT) scheduled for launch in 1999 is being developed based on the SeaWiFS Data Analysis System (SeaDAS). Such a simulation should include the spectral bands, orbital and scanning characteristics of the OSMI and KOMPSAT spacecraft. The simulation is also very helpful for finding and preparing for problem areas before launch. This paper describes a method to create simulated radiances of the OSMI over the oceans. Our method for constructing a simulated OSMI imagery is to propagate a KOMPSAT orbit over a field of Coastal Zone Color Scanner (CZCS) pigment values and to use the values and atmospheric components to calculate total radiances. A modified Brouwer - Lyddane model with drag was used for the realistic orbit prediction, the CZCS pigment data were used to compute water - leaving radiances, and a variety of radiative transfer models were used to calculate atmospheric contributions to total radiances detected by OSMI. Imagery of the simulated OSMI total radiances for 6 nominal bands was obtained. As expected, water - leaving radiances were only a small fraction of total radiances and sun glint contaminations were observed near the solar declination. Therefore, atmospheric correction is very important in the calculation of pigment concentration from total radiances. Because the imagery near the sun's glitter pattern is virtually useless and must be discarded, more advanced mission planning will be required.

  • PDF

Toward Next Generation Solar Coronagraph: Diagnostic Coronagraph Experiment

  • Cho, Kyung-Suk;Yang, Heesu;Lee, Jaeok;Bong, Suchan;Choi, Seonghwan;Kim, Jihun;Park, JongYup;Park, YoungDeuk;Kim, Yeon-Han
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.42.2-42.2
    • /
    • 2019
  • Korea Astronomy and Space Science Institute (KASI) has been developing a next-generation coronagraph (NGC) in cooperation with NASA to measure the coronal electron density, temperature, and speed using four different filters around 400 nm. To demonstrate technology for the measurement through the 2017 total solar eclipse across the USA, KASI organized an expedition team to demonstrate the coronagraph measurement scheme and the instrumental technology. The observation site was in Jackson Hole, Wyoming, USA. We built an eclipse observation system, so-called Diagnostic Coronal Experiment (DICE), which is composed of two identical telescopes to improve a signal to noise ratio. The observation was conducted with 4 wavelengths and 3 linear polarization directions according to the planned schedule in a limited total eclipse time of about 140 seconds.Polarization information of corona from the data was successfully obtained but we failed to get the coronal electron temperature and speed information due to a low signal-to-noise ratio of the optical system. In this study, we report the development of DICE and observation results. TSE observation and analysis by using our own developed instrument gave an important lesson that a coronagraph should be carefully designed to archive the scientific purpose. This experience through TSE observation will be very useful for a success of NASA-KASI joint missions called the Balloon-borne Investigation of the Temperature and Speed of Electrons in the Corona (BITSE) and COronal Diagnostic EXperiment (CODEX).

  • PDF

Landsat 8-based High Resolution Surface Broadband Albedo Retrieval (Landsat 8 위성 기반 고해상도 지표면 광대역 알베도 산출)

  • Lee, Darae;Seo, Minji;Lee, Kyeong-sang;Choi, Sungwon;sung, Noh-hun;Kim, Honghee;Jin, Donghyun;Kwon, Chaeyoung;Huh, Morang;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.741-746
    • /
    • 2016
  • Albedo is one of the climate variables that modulate absorption of solar energy, and its retrieval is important process for climate change study. High spatial resolution and long-term consistent periods are important considerations in order to efficiently use the retrieved albedo data. This study retrieved surface broadband albedo based on Landsat 8 as high resolution which is consistent with Landsat 7. First of all, we analyzed consistency of Landsat 7 channel and Landsat 8 channel. As a result, correlation coefficient(R) on all channels is average 0.96. Based on this analysis, we used multiple linear regression model using Landsat 7 albedo, which is being used in many studies, and Landsat 8 reflectance channel data. The regression coefficients of each channel calculated by regression analysis were used to derive a formula for converting the Landsat 8 reflectance channel data to broadband albedo. After Landsat 8 albedo calculated using the derived formula is compared with Landsat 7 albedo data, we confirmed consistency of two satellite using Root Mean Square Error (RMSE), R-square ($R^2$) and bias. As a result, $R^2$ is 0.89 and RMSE is 0.003 between Landsat 7 albedo and Landsat 8 albedo.

Development of Analysis Model for High-Performance Heat Pump (고성능 히트펌프 해석모델 개발 연구)

  • Yim, Sang-Sik;Kim, Ki-Bum;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6053-6059
    • /
    • 2013
  • Heat pumps have attracted considerable attention as a green energy system because they use renewable energy, such as geothermal, solar energy and waste heat, and can have a low electricity consumption rate compared to other conventional electric heating system. Many studies of high efficient heat pump system design was performed previously,but it is not easy to find any an analytical model that consists of components (e.g. compressor, heat exchangers, and expansion valve), not only having an interrelation and interconnection each other but also being flexible to any change in geometry and operating parameters. In this study, a computational model was developed for a heat pump with warm air as a heat source using the one-dimensional modeling software, AMESim. In combination with an independently-developed analytical model for a scroll compressor, the heat pump model can simulate the physical characteristics and actual behavior of the heat pump precisely. In addition, the reliability of the model was improved by verifying the simulation results using experimental data. The simulation data fell into the 10% error range compared with the experimental data. The heat pump model can be used for system optimization studies of product development and applied to other applications in a range of industrial field.

Factors Affecting Earth Science Problem-Solving Performances of Elementary School Pre-service Teachers: A Study on the Motions of the Moon and the Planets

  • Myeong, Jeon-Ok
    • Journal of the Korean earth science society
    • /
    • v.23 no.2
    • /
    • pp.180-187
    • /
    • 2002
  • The aim of this study was to investigate the factors affecting earth science problem-solving performances of elementary school pre-service teachers. The participants of the study were 81 students attending an elementary school teacher education university. The instruments of the study were paper-and-pencil tests, questionnaires, and interviews. The tests mainly measured the participants' problem solving abilities in the motions of the moon and the planets. Correlation and multiple regression techniques were used for data analysis. The results demonstrated that the pre-service teachers' problem solving abilities were low. Problem-solving performances were affected by the procedural knowledge, the participants' perception of the past earth science performance, self-efficacy, and the prerequisite declarative knowledge. Contrary to our expectation, the spatial visualization ability was not found to be related to the problem-solving performances. Implications of the study are drawn, and suggestions are made for further research.

A comparative analysis study of Green Building Certification Criteria - Focusing on the site and environment (친환경건축물인증제도의 외부환경요소적용에 관한 연구 - Site/environment를 중심으로)

  • Park, Chan-Hyuk;Oh, Myung-Won;Kim, Byung-Sun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.324-329
    • /
    • 2009
  • This paper is to provide problems and changes to be don Korean Green Building Certification Criteria, which are similar to American Leed certification and Japanese CASBBE, reorganizing and comparing those systems with domestic system. Normally, those certification program is very similar, but have some differences in the view to the site and environment chapter. That difference will be change to the right way that protect the nature states of the environment. Therefore, this study is going to base data to first step of the process for modify the differency problem.

  • PDF