Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

  • Park, Seung-Hee;Yun, Chung-Bang;Inman, Daniel J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.217-223
    • /
    • 2007
  • This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure.

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

The study on performance test of a city railroad power facilities detection device (도시철도 전력설비 이상검출용 장치 공장시험에 대한 고찰)

  • Im, Hyeong-Gil;Ryu, Ki-Seon;Jung, Ho-Sung;Choi, Kwang-Bum;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1930-1936
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF

Microfluidic Image Cytometry (μFIC) Assessments of Silver Nanoparticle Cytotoxicity

  • Park, Jonghoon;Yoon, Tae Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.4023-4027
    • /
    • 2012
  • Cytotoxicity assessment of silver nanoparticles (AgNPs) was performed using MTT-based microfluidic image cytometry (${\mu}FIC$). The $LC_{50}$ value of HeLa cells exposed to AgNPs in the microfluidic device was estimated as 46.7 mg/L, which is similar to that estimated by MTT-based IC for cells cultured in a 96 well plate (49.9 mg/L). These results confirm that the ${\mu}FIC$ approach can produce cytotoxicity data that is reasonably well-matched with that of the conventional 96 well plate system with much higher efficiency. This ${\mu}FIC$ method provides many benefits including ease of use and low cost, and is a more rapid in vitro cell based assay for AgNPs. This may aid in speeding up data acquisition in the field of nanosafety and make a significant contribution to the quantitative understanding of nanoproperty-toxicity relationships.

The Development of Power System Automation based on the CAN Communication Protocol (CAN 통신을 기반으로한 전력 시스템 자동화 구축)

  • Park, Jong-Chan;Kim, Beung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.3
    • /
    • pp.95-99
    • /
    • 2003
  • In this paper, the power system automation based on CAN communication protocol is introduced. Along with digitalization of electrical device, the various on-line services such as remote control, remote monitoring, remote parameter setting, fault data recording and remote diagnostic have been realized and become available. Therefore, it is necessary for those electrical devices to have real-time and reliable communication protocols. Author proposes DNPC(Distributed Network Protocol with CAN) which is proper to the power system SCADA (Supervisory Control And Data Acquisition) and DCS (Distributed Control System). The physical and datalink layer of DNPC protocol consists of the CAN2.0B which has the real-time characteristics and powerful error control scheme. As the transport and application layer, DNP3.0 is adopted because of its flexibility and compatible feature. Using the DNPC protocol, the power system automation is realized.

Development of RAW Data Storage Equipment for Operation Algorithm research of the Millimeter Wave Tracking Radar (밀리미터파 추적레이더 운용 알고리듬 연구를 위한 RAW 데이터 저장 장비 개발)

  • Choi, Jinkyu;Na, Kyoung-Il;Shin, Youngcheol;Hong, Soonil;Kim, Younjin;Kim, Hongrak;Joo, Jihan;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.57-62
    • /
    • 2022
  • Recently, the tracking radar continues research to develop a new operation algorithm that can acquire and track a target in various environments. In general, modeling similar to the real target and environment is used to develop a new operation algorithm, but there is a limit to modeling the real environment. In this paper, a RAW data storage device was developed to efficiently develop a new operation algorithm required for the tracking radar using millimeter wave to acquire and track the target. The RAW data storage equipment is designed so that the signal processing device of the tracking radar using millimeter wave can save the RAW data output from 8 channels to OOOMSPS. RAW data storage equipment consists of data acquisition equipment and data storage equipment. The data acquisition equipment was implemented using a commercial Xilinx KCU 105 Evaluation KIT capable of high-speed data communication interface, and the data storage equipment was implemented by applying a computer compatible with the commercial Xilinx KCU 105 Evaluation KIT. In this paper, the performance of the implemented RAW data storage equipment was verified through repeated interlocking tests with the signal processing device of the millimeter wave tracking radar.

A Study on Development and Application of Noise Estimation System for Floor Noise in Apartment Buildings (공동주택 층간소음의 소음 발생 위치 추정 시스템 개발 및 적용에 관한 연구)

  • Yun, Gee-Hyei;Kim, Sang-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.203-204
    • /
    • 2019
  • Recently, the number of conflicts and complaints related to noise between floors is increasing every year. It is essential to acquisition objective noise data in order to resolve legal disputes over floor noise. However, specialized equipment for noise acquisition is difficult for ordinary apartment dwellers to use. In addition, in order to solve the problem of inter-layer noise, it is most effective to locate and remove the noise. Therefore, this study proposes a floor noise monitoring system for the measurement of floor noise and estimation of the noise source that can be measured without a professional device.

  • PDF

Development of IoT-based data acquisition device (Gateway) for context-awareness of hospital facilities (병원 시설물의 상황 인지형 Light Things 제어를 위한 IoT기반 데이터 수집장치(Gateway) 개발)

  • Lee, Kack-Hee;Lee, Min-Woo;Cha, Jae-Sang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.4
    • /
    • pp.181-184
    • /
    • 2017
  • Korea is the world's top ten energy consumer, relying on foreign imports for 97% of its total energy. In 2007, energy imports amounted to US $ 95 billion, accounting for 26.6% of total imports. Thus, fundamental and long-term countermeasures against the same energy crisis It is a fact that is required. Despite the fact that the world is moving rapidly around the world in response to energy saving and low-carbon economic era, domestic movements are relatively slow. In this paper, we developed an IoT data collection device (Gateway) to control Light Things (lighting, signage, display, etc.) built in medium and large facilities under the assumption of hospital facilities, We propose the Light Things control algorithm and data acquisition (Gateway) development technology.

Field Application of Ultrasonic Inspection System for Stay Welds at Steam Generator of KSNP (한국표준형 원전 증기발생기 Stay 용접부 자동검사시스템 및 현장 검증)

  • Lim, Sa Hoe;Park, Chi Seung;Park, Chul Hoon;Joo, Keum Chong;Noh, Hee Chung;Yoon, Kwang Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • The stay cylinder weld at the steam generator of Korean Standard Nuclear Power Plants is safety class I component and is subjected to be inspected by the volumetric examination such as ultrasonic method. As accessibility of this area is limited due to the narrow space and high radiation, the existing manual inspection method involves various difficulties. Moreover operators may be exposed to internal contamination by contaminated dust during the surface buffing process to improve the inspection reliability of this area. Recently the new automatic inspection system for stay cylinder welds has been developed. The inspection system basically consists of a driving assembly, data acquisition device and signal processing units. The driving assembly is classified by 1) the scanner for inspecting and buffing the weld, 2) pillars for guiding the scanner and 3) the base frame for loading and supporting pillars. The scanner has 4 sensor modules to inspect in 4 refracted angles and 4 incident directions. These components can be inserted into the skirt of the stay cylinder through the manway hole and assembled easily by one-touch in the skirt. Data acquisition device and signal processing units developed in previous works are also newly upgraded for better processing of data analysis and evaluation. The system has been successfully demonstrated not only in the mock-up but also in the field. In this paper, newly developed inspection system for the stay cylinder weld of the steam generator is introduced and their field applications are discussed.

  • PDF

EPICS Based Vacuum Chamber Temperature Control System for PAL Storage Ring (가속기 저장링 진공 챔버 온도측정용 제어시스템 개발 및 EPICS 적용)

  • Yoon, J.C.;Choi, J.Y.;Kang, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2652-2654
    • /
    • 2005
  • A vacuum chamber temperature control system of Pohang Accelerator Laboratory (PAL) storage ring is a subsystem upgraded PAL control system, which is based upon Experimental Physics and Industrial Control System (EPICS) [1]. There are two control components, data acquisition system (SA120 data logger), development control system IOC (Input/Output Controller) at the storage ring of PAL. There are 240 vacuum chamber at the storage ring. It was a very important problem to solve how to monitor such a large number of vacuum chamber temperature distributed around the ring. The IOC connect MODBUS/JBUS field network to asynchronous serial ports for communication with serial device. It can simultaneously control up to 4 data acquisition systems. Upon receiving a command from a IOC running under Windows2k through the network, the IOC communicate through the slave serial interface ports to SA120. We added some software components on the top of EPICS toolkit. The design of the vacuum control system is discussed. This paper describes the development vacuum chamber temperature control system and how the design of this system.

  • PDF