• Title/Summary/Keyword: damped vibration

Search Result 202, Processing Time 0.02 seconds

Control of the along-wind response of steel framed buildings by using viscoelastic or friction dampers

  • Mazza, Fabio;Vulcano, Alfonso
    • Wind and Structures
    • /
    • v.10 no.3
    • /
    • pp.233-247
    • /
    • 2007
  • The insertion of steel braces has become a common technique to limit the deformability of steel framed buildings subjected to wind loads. However, when this technique is inadequate to keep floor accelerations within acceptable levels of human comfort, dampers placed in series with the steel braces can be adopted. To check the effectiveness of braces equipped with viscoelastic (VEDs) or friction dampers (FRDs), a numerical investigation is carried out focusing attention on a three-bay fifteen-storey steel framed building with K-braces. More precisely, three alternative structural solutions are examined for the purpose of controlling wind-induced vibrations: the insertion of additional diagonal braces; the insertion of additional diagonal braces equipped with dampers; the insertion of both additional diagonal braces and dampers supported by the existing K-braces. Additional braces and dampers are designed according to a simplified procedure based on a proportional stiffness criterion. A dynamic analysis is carried out in the time domain using a step-by-step initial-stress-like iterative procedure. Along-wind loads are considered at each storey assuming the time histories of the wind velocity, for a return period $T_r=5$ years, according to an equivalent wind spectrum technique. The behaviour of the structural members, except dampers, is assumed linear elastic. A VED and an FRD are idealized by a six-element generalized model and a bilinear (rigid-plastic) model, respectively. The results show that the structure with damped additional braces can be considered, among those examined, the most effective to control vibrations due to wind, particularly the floor accelerations. Moreover, once the stiffness of the additional braces is selected, the VEDs are slightly more efficient than the FRDs, because they, unlike the FRDs, dissipate energy also for small amplitude vibrations.

APPLICATION OF VISCOELASTIC DAMPING FOR PASSIVE VIBRATION CONTROL IN AUTOMOTIVE ROOF USING EQUIVALENT PROPERTIES

  • LEE K. H.;KIM C. M.
    • International Journal of Automotive Technology
    • /
    • v.6 no.6
    • /
    • pp.607-613
    • /
    • 2005
  • In this study, a simplified approach to modeling the dynamic characteristics of passive constrained layer damping treatments in finite element models is presented. The basic concept is to represent multi-layered composite structures using an equivalent single layer. The equivalent properties are obtained by using the RKU (Ross, Kerwin and Ungar) equations. Comparisons are given between results obtained by the dynamic analysis of the simple models implemented in MSC/NASTRAN and by test measurements. Surface damping treatments are applied to automotive panels as well as simple structures. Using the proposed equivalent modeling technique, higher computational efficiency for the damped composite structures has been obtained.

Vibration Characteristics of Boxthorn(Lycium chinense Mill) (구기자 가지의 진동 특성)

  • 서정덕
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.105-114
    • /
    • 2001
  • Modulus of elasticity, modulus of rigidity, damping ratio, and natural frequency of three varieties of boxthorn (Lycium chinense Mill) (Cheongyang #2, Cheongyang gugija, and Cheongyang native) branches were analyzed. Modulus of elasticity and modulus of elasticity and modulus of rigidity of the boxthorn branch was determined using standard formula after simple beam bending and torsion test, respectively, using an universal testing machine. Damping ratio and natural frequency of branches were determined using a system consisted of an accelerometer, a PC equipped with A/D converter, and a software for data analysis. Relationship between the elastic modulus and branch diameter in overall varieties and branch types showed a good correlation (r -0.81). There was, however, no correlation between torsional rigidity and branch diameter. The internal damping results were highly variable and the overall range of the damping ratio of the boxthorn branch was 0.014-0.087, which indicated that the branch was a lightly damped structure. The natural frequency of the boxthorn branch was in the range of 89-363 rad/s for the overall varieties and branch types. A good correlation (r 0.82) existed between the natural frequency and branch diameter in overall varieties and branch type.

  • PDF

The Improvement of Leakage Error in Digital courier Transform (디지털 푸리에 변환에서 누설오차의 개선)

  • 정의봉;안세진;장호엽;장진혁
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.455-460
    • /
    • 2001
  • An exact spectrum wish no leakage error could be obtained when the period of the signal coincides perfectly with the record length. However, the record length will be determined regardless of the period of signal. The Leakage error due to this problem will gibe a distorted spectrum. In the conventional research, the method was proposed to estimate the three parameters, frequency, amplitude and phase angle, from the spectrum data for anundamped sinusoidal signal. In this paper, some techniques are proposed to estimate frequency, amplitude and damping ratios from the frequency response functions for damped signals. The validation of the proposed techniques is verified by several numerical examples.

  • PDF

Input Shaping for Servo Control of Machine Tools (공작기계의 서보제어와 입력성형기법)

  • Kim, Byung-Sub
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1011-1017
    • /
    • 2011
  • Servo control loops are a core part in the control architecture of machine tools. Servo control loops manage acceleration, velocity and position of all the axes in a machine tool based on commands. The performance of servo control loops sets the basis for quality of production paris and cycle time reduction. First, this paper presents a general control architecture of machine tools and several control schemes in literature, which can be applicable to machine tools control; including Zero Phase Error Tracking Control (ZPETC) and Cross Coupling Control (CCC). After that, modem control strategies to mitigate the problem of high speed machining are reviewed. In high speed machining, high accelerations excite the machine structure up to high frequencies, thereby exciting the structure's modes of vibration. These structural vibrations need to be damped if accurate positioning or trajectory following is required. Input shaping is an attractive option in dealing with structural vibrations. The advantages and drawbacks of using input shaping technique for machine tools are discussed in detail.

SUBOPTIMAL VIBRATION CONTROL OF FLEXIBLE ROBOT BEARING SYSTEM BY USING A MAGNETIC BEARING

  • Lee, Chong-Won;Kim, Jong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.255-259
    • /
    • 1989
  • A suboptimal output feedback controller is designed and applied to a flexible rotor bearing system in order to control the unstable or lilghtly damped vibrations. The reduced order model is the truncated modal equation of the distributed parameter system obtained through the singular perturbation. The instability problem arising from the spillover effects caused by the uncontrolled high frequency modes is prevented through the constrained optimization by incorporating the spillover term into the performance index. The efficiency of the proposed method is demonstrated experimentally with a flexible rotor by using a magnetic bearing.

  • PDF

Spectral Analysis Method for the Discrete Systems with Initial Conditions (초기조건을 갖는 이산계의 과도응답에 대한 스펙트럴해석법)

  • Kim Sunghwan;Cho Jooyong;Lee Usik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.578-583
    • /
    • 2005
  • This paper introduces a fast Fourier transform (FFT)-based spectral dynamic analysis method for the transient responses as well as the steady-state responses of the linear discrete systems subject to non-zero initial conditions. The forced vibration of a viscously damped three-DOF system is considered as the illustrative numerical example. The proposed spectral analysis method is evaluated by comparing its results with the exact analytical solutions and the numerical solutions obtained by the Runge-Kutta method.

Aerodynamic Methods for Mitigating the Wind-Induced Motions on the Tall Buildings (고층건축물의 풍진동 저감을 위한 공기역학적 방법)

  • Ha Young-Cheol;Kim Dong-Woo
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.431-434
    • /
    • 2002
  • The excessive wind-induced motion of tall buildings most frequently result from vortex shedding induced across-wind oscillations. This form of excitation is most pronounced far relatively flexible, lightweight and lightly damped structure, e.g. tall building. This paper discusses aerodynamic means for mitigating the across-wind vortex shedding induced in such situations. Emphasis is on the change of the building cross section to design the building with openings from side to side which provide pressure equalization and tend to reduced the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. Wind tunnel test have been carried out on the Kumoh National University of Technology using rigid models with twenty-four kinds of opening shapes. Form these results, the effective opening shape, size and location for building to reducing wind-induced vortex shedding and responses are pointed out.

  • PDF

Development of High Speed Digital Signal Processing Unit for Active Control of Noise Fields in Passenger Car (자동차 실내소음의 능동제어를 위한 고속 이산 신호처리 장치 개발)

  • 김인수;이강모;허현무;홍석윤
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.205-214
    • /
    • 1996
  • Active noise control(ANC) requires the full capability of a modern digital signal processing module. This paper describes the digital signal processing unit which is designed for ANC of noise fields in passenger car. System hardware is designed to allow software controlled versatility as well as fully qutomatic operation. The developed system is provided with the ability to be self-operated except the case of upload/download of data and program between the personal computer and the system memory. Experimental results are presented to demonstrate ANC performance of noise fields in lightly damped enclosure and passenger car.

  • PDF

Steady State Respknse of a Rotor Supported on Cavitated Squeeze Film Dampers (공동 스퀴즈 필름 댐퍼에 지지된 회전체의 정상상태 응답 해석)

  • 정시영;정재천;심상규
    • Journal of KSNVE
    • /
    • v.2 no.3
    • /
    • pp.213-222
    • /
    • 1992
  • The effect of cavitation on the synchronous steady state response of a single rotor supported on cavitated squeeze film dampers executing a circular orbit is investigated theoretically. The Swift-Stieber boundary conditions and a long bearing approximation are utillized to evaluate the direct and the cross coupled damping coefficients of a cavitated squeeze film damper. For typical design parameters, frequency response curves are presented here to exhibit the effect of cavitation on the imbalance response and transmissibilities for both a flexible rotor and a rigid rotor. Investigations show that cavitation occured in a squeeze film damper produces bistable jump phenomena and deteriorates the performance of a squeeze film damper. This arises from that the large cavity causes substantial increment of the cross coupled damping which has radial stiffening effect. Furthermore, the large cavity causes the decrement of the direct damping which has pure damping effect. It is also observed that in the absence of cavitation, both rotor excursion amplitude and imbalance transmissibilities are very well damped.

  • PDF