Effect of introducing RC infill on seismic performance of damaged RC frames

  • Turk, Ahmet Murat;Ersoy, Ugur;Ozcebe, Guney
    • Structural Engineering and Mechanics
    • /
    • v.23 no.5
    • /
    • pp.469-486
    • /
    • 2006
  • The main objective of this study was to investigate the seismic behavior of damaged reinforced concrete frames rehabilitated by introducing cast in place reinforced concrete infills. Four bare and five infilled frames were constructed and tested. Each specimen consisted of two (twin) 1/3-scale, one-bay and two-story reinforced concrete frames. Test specimens were tested under reversed-cyclic lateral loading until considerable damage occurred. RC infills were then introduced to the damaged specimens. One bare specimen was infilled without being subjected to any damage. All infilled frames were then tested under reversed-cyclic lateral loading until failure. While some of the test frames were detailed properly according to the current Turkish seismic code, others were built with the common deficiencies observed in existing residential buildings. The variables investigated were the effects of the damage level and deficiencies in the bare frame on the seismic behavior of the infilled frame. The deficiencies in the frame were; low concrete strength, inadequate confinement at member ends, 90 degree hooks in column and beam ties and inadequate length of lapped splices in column longitudinal bars made above the floor levels. Test results revealed that both the lateral strength and lateral stiffness increased significantly with the introduction of reinforced concrete infills even when the frame had the deficiencies mentioned above. The deficiency which affected the behavior of infilled frames most adversely was the presence of lap splices in column longitudinal reinforcement.

Behaviour of Concrete Building with High Temperature (콘크리트의 고온에서의 거동)

  • 이병곤;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.140-145
    • /
    • 1997
  • The main purpose of this study is to establish the reliable method for evaluating fire damage of reinforced concrete building, by using the rational procedure, and to develope the rehabilitation methods of fire damaged concrete structures. Especially, this proposed evaluation method is applied to the fire damaged concrete buildings of domestic, and the rehabilitation methods on the basis of these applied results are proposed and those example are shown. The proposed rational evaluation method for fire damaged concrete building proceeds is estimating the reduction of the mechanical properties of concrete of fire damaged structural members in comparison with the experimental results which are obtained from the compression tests of heated concrete specimens under various temperatures.

  • PDF

Application of ultra-high performance fiber reinforced concrete for retrofitting the damaged exterior reinforced concrete beam-column joints

  • Al-Osta, Mohammed A.;Khan, Muhammad I.;Bahraq, Ashraf A.;Xu, Shi-Yu
    • Earthquakes and Structures
    • /
    • v.19 no.5
    • /
    • pp.361-377
    • /
    • 2020
  • In the present research work, the effectiveness and the efficiency of a retrofitting approach using a layer of ultra-high performance fiber reinforced concrete (UHPFRC) jacket for damaged substandard exterior beam-column joints (BCJs) is experimentally investigated. The main objective of this study is to rehabilitate the already damaged BCJs to meet the serviceability requirements without compromising safety. According to the proposed strengthening technique, a chipped surface, lightly brushed with a dry condition was selected for making a successful bond between normal concrete substrate surface (NCSS) and UHPFRC. Then a fresh UHPFRC jacket with a thickness of 30 mm was cast around the damaged specimens. The entire test matrix was comprised of three 1/3 scale damaged exterior BCJs with a different column axial load (CAL). These specimens were repaired with UHPFRC and retested under monotonic loading. Based on the experimental results, repaired specimens showed an excellent performance in terms of their load-displacement response, maximum strength, displacement ductility, initial stiffness, secant stiffness and energy dissipation capacity when compared with the corresponding values registered when these specimens were tested in their virgin state. This rehabilitative intervention not only restored the strength, stiffness, ductility and energy dissipation capacity of severely damaged specimens but also improved their performance.

Fire Resistant Performance after Application of Repaired Materials for Fire-Damaged Reinforced Concrete Column (화재피해를 입은 철근콘크리트 단주시험체의 보수재료 적용 후 내화성능 평가)

  • Sim, Sang-Rak;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.147-154
    • /
    • 2020
  • Currently, there are no specific repair methods for RC structures damaged by fire, and repair methods are applied when durability deteriorates due to aging. In addition, a number of recent studies have been reported that have conducted fire resistance assessment of the repair materials themselves, assuming exposure to high-temperature environments such as fires. However, researches that evaluate the fire resistance performance of the repair materials by applying existing repair materials to the actual fire damaged reinforced concrete structures are very rare. Therefore, in this study, a number of existing repair materials were applied to fire-damaged concrete column to compare and evaluate the fire resistance performance with the original cover concrete.

Numerical Modeling of Residual Behavior of Fire-Damaged Reinforced Concrete Interior Columns (화해를 입은 철근콘크리트 내부기둥의 잔존거동 수치해석 모델)

  • Lee Chadon;Shin Yeong-Soo;Lee Seung-Whan;Lee Chang-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.893-902
    • /
    • 2005
  • Reasonable prediction of residual capacity of fire-damaged reinforced columns is important for both the safety measurement and the rehabilitation of the reinforced concrete structures suffered from exposure to extensive fire. In order to predict the residual behavior of fire-damaged reinforced concrete columns, its predictive model must be able to take into account the amount of heat transferred into the column, the level of deterioration of constituent materials and various column geometries. The numerical model presented in this research includes all these factors. The model has been shown to reasonably predict the residual behavior of fire-damaged columns. Parametric studies were performed using this model for the effects of cover thickness, exposure time to fire and column geometries on the residual behavior of reinforced concrete columns. It was found that serious damage on the residual capacity of column resulted from a longer exposure time to fire but only marginal differences from other factors.

Numerical Study on the Fire Damaged Reinforced Concrete Building Structures Considering Influencing Fire Case and Parameters of Columns (화재피해를 받은 철근콘크리트 건축물의 기둥의 영향인자를 고려한 해석적 연구)

  • Suh, Yeonwoo;Son, Hee Ju
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.101-112
    • /
    • 2022
  • Expanding urbanization practices result in high numbers of buildings being developed in city centers. This high building concentration leads to an increased fire risk, resulting in higher casualty rates and increased economic damages compared to fires in the past. The purpose of this study was to analyze the structural behavior of fire-damaged reinforced concrete buildings using analytical methods and to suggest methods of improving fire resistance in the event of a fire. Damage levels were measured using commercial software to apply the finite element method, ABAQUS, and MIDAS GEN to the dataset. Load-deflection curves were calculated using the effective area and moment of inertia of the fire-damaged columns provided by ABAQUS. The results of this analysis indicate that fire-damaged beams with experience greater deflection from indoor fires than they will from outdoor fires. Fires that occurred on the middle floors were more dangerous than those occurring on higher floors, and eccentrically loaded columns experienced more damage than axially loaded columns. The results indicate that these methods accurately predict structural behaviors of fire damaged concrete columns by considering fire exposure area and eccentric loading.

Strengthening of concrete damaged by mechanical loading and elevated temperature

  • Ahmad, Hammad;Hameed, Rashid;Riaz, Muhammad Rizwan;Gillani, Asad Ali
    • Advances in concrete construction
    • /
    • v.6 no.6
    • /
    • pp.645-658
    • /
    • 2018
  • Despite being one of the most abundantly used construction materials because of its exceptional properties, concrete is susceptible to deterioration and damage due to various factors particularly corrosion, improper loading, poor workmanship and design discrepancies, and as a result concrete structures require retrofitting and strengthening. In recent times, Fiber Reinforced Polymer (FRP) composites have substituted the conventional techniques of retrofitting and strengthening of damaged concrete. Most of the research studies related to concrete strengthening using FRP have been performed on undamaged test specimens. This contribution presents the results of an experimental study in which concrete specimens were damaged by mechanical loading and elevated temperature in laboratory prior to application of Carbon Fiber Reinforced Polymer (CFRP) sheets for strengthening. The test specimens prepared using concrete of target compressive strength of 28 MPa at 28 days were subjected to compressive and splitting tensile testing up to failure and the intact pieces of the failed specimens were collected for the purpose of repair. In order to induce damage as a result of elevated temperature, the concrete cylinders were subjected to $400^{\circ}C$ and $800^{\circ}C$ temperature for two hours duration. Concrete cylinders damaged under compressive and split tensile loads were re-cast using concrete and rich cement-sand mortar, respectively and then strengthened using CFRP wrap. Concrete cylinders damaged due to elevated temperature were also strengthened using CFRP wrap. Re-cast and strengthened concrete cylinders were tested in compression and splitting tension. The obtained results revealed that re-casting of specimens damaged by mechanical loadings using concrete & mortar, and then strengthened by single layer CFRP wrap exhibited strength even higher than their original values. In case of specimens damaged by elevated temperature, the results indicated that concrete strength is significantly dropped and strengthening using CFRP wrap made it possible to not only recover the lost strength but also resulted in concrete strength greater than the original value.

CFS Strengthening Effect of Reinforced Concrete Beams under Loading States (재하상태에 따른 철근콘크리트 보의 탄소섬유쉬트 보강효과)

  • 김민수;오용복;권영웅
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.757-762
    • /
    • 2000
  • The target of this study is to compare and analyze the strengthening effect of damaged reinforced concrete beams under unloading and loading conditions through the simulation of strengthening condition in real structures. The conclusion of test results are as follows : For the concrete beam wrapped at the side in addition to be strengthened at the bottom, the strength and stiffness increase. although the flexural capacity depends on the strengthening method, it generally shows that the strength improve in the range of 22% to 39% in comparison with the specimen without strengthening. In case of applying th equation suggested by CangaRao & Vijay for the wraped concrete beam, it must be modified because it is likely to overestimate the flexural capacity considering the height of wrapping as the width of concrete. The strength an stiffness of reinforced concrete beams in proportion to the percentage of damage decrease. Damaged beams, which are strengthened by CFS, is structurally efficient and show reduction of strength comparing with the specimen without strengthening but stiffness is increasing.

  • PDF

Effect of cover cracking on reliability of corroded reinforced concrete structures

  • Chen, Hua-Peng;Nepal, Jaya
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.511-519
    • /
    • 2017
  • The reliability of reinforced concrete structures is frequently compromised by the deterioration caused by reinforcement corrosion. Evaluating the effect caused by reinforcement corrosion on structural behaviour of corrosion damaged concrete structures is essential for effective and reliable infrastructure management. In lifecycle management of corrosion affected reinforced concrete structures, it is difficult to correctly assess the lifecycle performance due to the uncertainties associated with structural resistance deterioration. This paper presents a stochastic deterioration modelling approach to evaluate the performance deterioration of corroded concrete structures during their service life. The flexural strength deterioration is analytically predicted on the basis of bond strength evolution caused by reinforcement corrosion, which is examined by the experimental and field data available. An assessment criterion is defined to evaluate the flexural strength deterioration for the time-dependent reliability analysis. The results from the worked examples show that the proposed approach is capable of evaluating the structural reliability of corrosion damaged concrete structures.

Non destructive test of Fire-damaged reinforced concreted beams with high strength concrete (화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 비파괴 검사)

  • 신미경;신영수;이차돈;홍성걸;김희선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.651-654
    • /
    • 2003
  • Non-destructive testing is essential in the inspection of alteration, repair and new construction in construction industry. This paper is to evaluate the strength variation of fire damaged concrete by non-destructive testing. Furthermore, It is to infer the recovery degree of residual strength of fire-damaged concrete. For this purpose, researchers are exploring the performance of non-destructive testing method using ultrasonic testing and Schmidt hammer in concrete specimens. Testing is performed four-times: before fire test, directly after fire test, after 20 days and after 60 days.