• Title/Summary/Keyword: damage level

Search Result 2,989, Processing Time 0.029 seconds

Experimental Verifications of Fatigue Crack Identification Method Using Excitation Force Level Control for a Cantilever Beam (외팔보에 대한 가진력수준제어를 통한 피로균열규명기법의 실험적 검증)

  • Kim Do-Gyoon;Lee Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.10
    • /
    • pp.1467-1474
    • /
    • 2004
  • In this study, a new damage identification method for beam-like structures with a fatigue crack is proposed. which does not require comparative measurement on an intact structure but require several measurements at different level of excitation forces on the cracked structure. The idea comes from the fact that dynamic behavior of a structure with a fatigue crack changes with the level of the excitation force. The 2$^{nd}$ spatial derivatives of frequency response functions along the longitudinal direction of a beam are used as the sensitive indicator of crack existence. Then, weighting function is employed in the averaging process in frequency domain to account for the modal participation of the differences between the dynamic behavior of a beam with a fatigue crack at the low excitation and one at the high excitation. Subsequently, a damage index is defined such that the location and level of the crack may be identified. It is shown from the analysis of vibration measurements in this study that comparison of frequency response characteristics of a beam with a single fatigue crack at different level of excitation forces enables an effective detection of the crack.

Studies on Varietal Resistance to Sheath Blight Disease in Rice II. Varietal Difference of Resistance (벼 품종의 잎집무늬마름병 저항성 연구 II. 품종간 저항성의 차이)

  • Kim, Kwang-Ho;Yang, Kae-Jin;Lee, Sang-Bok
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.32 no.3
    • /
    • pp.302-309
    • /
    • 1987
  • One hundred rice varieties were tested for their level of resistance to sheath blight disease at adult plant stage in field condition through 1984 to 1986. Rice plants were grown under ordinary seasonal culture and inoculated by k-2 fungus isolate during three years. k -1 isolate was also inoculated separately in 1984 and test under late seasonal culture was conducted in separate field in 1985. Degree of damage by the disease observed at 25 days after heading was used to identify the level of resistance of the rice varieties tested. Varietal differences of degree of damage were significant in five tests during three years, and the genotypic variance of degree of damage was always higher than environmental variance among varieties tested. Positive correlations between testing years, between cultural seasons, and between isolates inoculated were found in degree of damage of varieties tested for two or three years continuously. Degree of damage by the disease was correlated negatively with heading date of rice varieties except 1984 tests. Thus, the level of resistance should be compared among the variety group having almost same heading date in field condition, and late and extremely late variety groups should be tested for their level of resistance under appropriate environmental condition. Gayabyo, an early heading variety, and SR9713-54-3, a medium heading breeding line, showed consistent lower value of degree of damage during two or three years. These two varieties were selected as moderate resistant germplasm.

  • PDF

The impact of successive earthquakes on the seismic damage of multistorey 3D R/C buildings

  • Kostinakis, Konstantinos;Morfidis, Konstantinos
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Historical earthquakes have shown that successive seismic events may occur in regions of high seismicity. Such a sequence of earthquakes has the potential to increase the damage level of the structures, since any rehabilitation between the successive ground motions is practically impossible due to lack of time. Few studies about this issue can be found in literature, most of which focused their attention on the seismic response of SDOF systems or planar frame structures. The aim of the present study is to examine the impact of seismic sequences on the damage level of 3D multistorey R/C buildings with various structural systems. For the purposes of the above investigation a comprehensive assessment is conducted using three double-symmetric and three asymmetric in plan medium-rise R/C buildings, which are designed on the basis of the current seismic codes. The buildings are analyzed by nonlinear time response analysis using 80 bidirectional seismic sequences. In order to account for the variable orientation of the seismic motion, the two horizontal accelerograms of each earthquake record are applied along horizontal orthogonal axes forming 12 different angles with the structural axes. The assessment of the results revealed that successive ground motions can lead to significant increase of the structural damage compared to the damage caused by the corresponding single seismic events. Furthermore, the incident angle can radically alter the successive earthquake phenomenon depending on the special characteristics of the structure, the number of the sequential earthquakes, as well as the distance of the record from the fault.

Protective Effect of Buplueri Radix (BR) Against 1,2,4-benzentriol Induced DNA Damage in Human Lymphocytes (Buplueri Radix 의 1,2,4-benzentriol에 의해 유발된 DNA Damage에 대한 보호효과에 대한 연구)

  • Lee, Young-Joon;Kang, Su-Jin
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.12 no.2
    • /
    • pp.51-59
    • /
    • 2008
  • Objectives : Buplueri Radix (BR), used medical plant in Korea traditional medicine, contains various compounds, including a series of triterpene saponins known as saikosaponins. We performed this study for the protective effect of BR against oxidative damage induced by 1,2,4-benzentriol(BT) in human lymphocytes. Methods : In order to investigate the protective effect of BR against carcinogens, genotoxicity induced by benzene metabolite, BT were performed using cytokinesis-block micronucleus(CBMN) assay and comet assay. Results : The frequency of micronucleus at 25, 50 and $100{\mu}M$ concentration of BT were $8{\pm}2.36$, $23{\pm}2.31$, $35{\pm}4.17$ respectively. In addition of BR with concentration of 25 and $50{\mu}g/mL$, MN frequencies were significantly decreased. According to comet assay, BT induced DNA damage in a dose-dependent manner at concentration of 10 and 50 while BT with BR treatment decreased DNA breakage. No genotoxicity was observed by BR($25{\sim}50{\mu}g/mL$) treatment alone on DNA breakage. Since BT can induce DNA damage through the generation of reactive oxygen species(ROS), we examined the level of ROS in human lymphocytes treated with BT and/or BR using DCF-DA, ROS-sensitive probe. The generation of ROS in BT-treated cells was also observed, and BR addition inhibited the level of BT-induced DNA damage. Conclusions : From above results it is suggested that BR could protect the cell and DNA from pro-oxidant effect by ROS by BT

  • PDF

Recent Occurrence Status of Two Major Fruit Moths, Oriental Fruit Moth and Peach Fruit Moth in Apple Orchards (사과 주산지 사과원에서 2종 심식나방류의 발생동향)

  • Choi, Kyung-Hee;Lee, Soon-Won;Lee, Dong-Hyuk;Kim, Dong-A;Kim, Soon-Kyung
    • Korean journal of applied entomology
    • /
    • v.47 no.1
    • /
    • pp.17-22
    • /
    • 2008
  • This survey was conducted from 1992 to 2005 in the major apple producing districts in southern part of South Korea including $4{\sim}8$ cities, to know the occurrence and damage level of two major pests, Carposina sasakii and Grapholita molesta that attack apple fruit. The fruit damage by G. molesta during the harvest period ranged from 0.02 to 1.64%. A tendency of higher damage of G. molesta was observed after 1997 compared with the previous years. The other hand, the fruit damage by C. sasakii was 0.02 to 1.30%, and the damage level was very low with fruit damage of < 0.3% except 1998. The orchard infested with G. molesta was 13 to 71 %, while 12 to 57% with C. sasakii. The rates of orchards where fruit damage by G. molesta was found were higher than those by C. sasakii after 1997. The tendency of fruit damage rates in the orchard where the most fruit damage was found was same with the trend of orchard rates infested with the pests. The maximum damage rate by G. molesta was 20.0% in 2005, while 4.5% by C. sasakii in 1998. The damaged shoot rates by the first generation G. molesta was $0.1{\sim}8.1%$, and it had a positive correlation with the rates of fruit damage during the harvest period. Consequently, it is concluded that G. molesta is dominant species compared with C. sasakii in commercial apple orchards recently.

Tensile Strength Change of Circular Structural member with Artificial Sectional Surface Damage (인위적 표면 단면손상 수준에 따른 원형 부재의 인장성능 변화)

  • Ha, Min-Gyun;Kwon, Tae-Yun;Lee, Won-Hong;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.100-109
    • /
    • 2021
  • This study was examined the tensile strength change of a circular tubular member with artificial sectional damage on its surface to consider surface sectional damage by corrosion. The tensile strength tests were conducted using circular tubular specimens with artificial sectional damage considering sectional damaged height and width on its surface according to the corrosion level. From the tensile strength test results, it is confirmed that tensile strength of the circular tubular specimens was affected by the damaged circumference (damaged width), not damaged length (damaged height) and their tensile failures were appeared at the minimum section of the artificial sectional damage part. Nonlinear finite-element analyses were conducted considering equivalent sectional damage effect on sectional damaged part in tensile specimens to examine the change in the tensile strength of tubular specimens with artificial sectional damage since it is difficult to estimate the sectional damaged surface condition of the specimens clearly. From the nonlinear finite element analysis results for the tensile test specimens, tensile strengths of test specimens with irregular sectional damaged surface were relatively evaluated to be highly decreased than these of FE analysis model with equivalent sectional damage. Therefore, residual tensile strengths of tensile members with irregular sectional damage as local corrosion can be evaluated and predicted using correlation coefficient between tensile test results and FE analysis results with equivalent sectional damage.

Damage detection in truss bridges using transmissibility and machine learning algorithm: Application to Nam O bridge

  • Nguyen, Duong Huong;Tran-Ngoc, H.;Bui-Tien, T.;De Roeck, Guido;Wahab, Magd Abdel
    • Smart Structures and Systems
    • /
    • v.26 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • This paper proposes the use of transmissibility functions combined with a machine learning algorithm, Artificial Neural Networks (ANNs), to assess damage in a truss bridge. A new approach method, which makes use of the input parameters calculated from the transmissibility function, is proposed. The network not only can predict the existence of damage, but also can classify the damage types and identity the location of the damage. Sensors are installed in the truss joints in order to measure the bridge vibration responses under train and ambient excitations. A finite element (FE) model is constructed for the bridge and updated using FE software and experimental data. Both single damage and multiple damage cases are simulated in the bridge model with different scenarios. In each scenario, the vibration responses at the considered nodes are recorded and then used to calculate the transmissibility functions. The transmissibility damage indicators are calculated and stored as ANNs inputs. The outputs of the ANNs are the damage type, location and severity. Two machine learning algorithms are used; one for classifying the type and location of damage, whereas the other for finding the severity of damage. The measurements of the Nam O bridge, a truss railway bridge in Vietnam, is used to illustrate the method. The proposed method not only can distinguish the damage type, but also it can accurately identify damage level.

Estimation of the Maximum Wind to Surface Using Wind Profile in Typhoon and Gust Factor (태풍 연직프로파일과 gust factor를 이용한 지상의 최대풍속 추정)

  • Jung, Woo-Sik;Park, Jong-Kil;Choi, Hyo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.290-292
    • /
    • 2008
  • we applied Wind Field Module of PHRLM so that disaster prevention agency concerned can effectively estimate the possible strong wind damages by typhoon. In this study, therefore, we estimated wind speed at 300m level using 700hPa wind according to the research method by Franklin(2003), PHRLM(2003), and Vickery and Skerlj(2005). Then we calculated wind speed at 10m level using the estimated wind speed at 300m level, and finally, peak 3.second gust on surface. The case period is from 18LST August 31 to 03LST September 1, 2002, when the typhoon Rusa in 2002 was the most intense. Among disaster prediction models in the US, Wind Field Module of PHRLM in Florida was used for the 2002 typhoon Rusa case. As a result, peak 3.second gust on the surface increased $10\sim20%$ in the typhoon's 700hPa wind speed.

  • PDF

A two-level parallel algorithm for material nonlinearity problems

  • Lee, Jeeho;Kim, Min Seok
    • Structural Engineering and Mechanics
    • /
    • v.38 no.4
    • /
    • pp.405-416
    • /
    • 2011
  • An efficient two-level domain decomposition parallel algorithm is suggested to solve large-DOF structural problems with nonlinear material models generating unsymmetric tangent matrices, such as a group of plastic-damage material models. The parallel version of the stabilized bi-conjugate gradient method is developed to solve unsymmetric coarse problems iteratively. In the present approach the coarse DOF system is solved parallelly on each processor rather than the whole system equation to minimize the data communication between processors, which is appropriate to maintain the computing performance on a non-supercomputer level cluster system. The performance test results show that the suggested algorithm provides scalability on computing performance and an efficient approach to solve large-DOF nonlinear structural problems on a cluster system.

Ultraviolet Radiation-Induced Apoptosis is Inversely Correlated with the Expression Level of Poly(ADP-ribose) Polymerase

  • Oh, Kyu Seon;Lee, Dong Wook;Chang, Jeong Hyun;Moon, Yong Suk;Um, Kyung ll
    • Animal cells and systems
    • /
    • v.5 no.1
    • /
    • pp.77-83
    • /
    • 2001
  • The present study was conducted to elucidate whether the expression level of poly(ADP-ribose) polymerase (PARP) is related to the ultraviolet radiation (UV)-induced apoptosis. After treatment of the mammalian cell lines HeLa S3 and Chinese hamster ovary (CHO) with 50 J/m2 UV, induction of apoptosis was determined by several means during 24 h post-incubation. Incidence of apoptosis was much lower in CHO than HeLa S3 cells based on the percentage of apoptotic cells in terms of morphological changes in nucleus or direct counting of viable cells and qualitative or quantitative DNA fragmentation. Interestingly, when the expression level of PARP was measured by western blotting, the amounts of PARP that was retained at each time point inversely correlated with the incidences of apoptosis in these cells. Concomitant with generation of the 85 kDa fragment, 116 kDa PARP disappeared in HeLa S3 within 6 h after UV treatment, whereas a fair amounts of 116 kDa band was still retained in CHO cells at 36 h post-incubation. This inverse relationship was also observed in the adaptive response system, in which cells weve treated with a high dose of UV after pretreatment with a low dose. As expected, typical adaptive responses appeared in CHO cells but not in HeLa cells, showing greater cell viability and lesser DNA fragmentation. During the adaptive response in CHO cells, PARP was expressed at much higher level compared to the single, high dose-treated cells. Interestingly, even though PARP was induced at 6 h post-incubation In both cell types, its expression was more prominent in CHO cells. Thus, our data indicate that the retained level of intact PARP against UV damage inversely correlates with incidence of apoptosis in mammalian cells, and also suggest that a machinery to protect the PARP degradation against UV damage exists in CHO but not in HeLa S3 cells.

  • PDF