• Title/Summary/Keyword: damage diagnosis

Search Result 584, Processing Time 0.022 seconds

Survey of Damage Cases for Surge Protective Devices Installed Electrical Communication Systems and Analysis of Degradation Diagnosis Method (전자통신설비의 SPD 소손사례 및 열화진단기법 분석)

  • Lim, Jong-Wook;Lee, Jae-Young;Kwon, June-Hyuk
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.15-18
    • /
    • 2009
  • In recent years electric devices and telecommunication facilities were often damaged by surge generated lightning discharge. When the service was interrupted by failure of electrical devices due to surge the social loss is very enormous. Therefore in order to protect electrical systems against lightning, SPDs(Surge protective device) have been used But damaged SPDs often make some troubles like fire and interrupt of service. In this work, 3rd harmonic leakage current defection method was applied as the diagnosis of SPD degradation and the effectiveness of this method was verified by field survey.

  • PDF

Development of Intelligent System for Moving Condition Diagnosis of the Machine Driving System (기계구동계의 작동상태 진단을 위한 지능형 시스템의 개발)

  • 박흥식
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.42-49
    • /
    • 1998
  • This wear debris can be harvested from the lubricants of operating machinery and its morphology is directly related to the damage to the interacting surface from which the particles originated. The morphological identification of wear debris can therefore provide very early detection of a fault and can also often facilitate a diagnosis. The purpose of this study is to attempt the developement of intelligent system for moving condition diagnosis of the machine driving system. The four shape parameter(50% volumetric diameter, aspect, roundness and reflectivity) of war debris are used as inputs to the neural network and learned the moving condition of five values(material3, applied load 1, sliding distance 1). It is shown that identification results depend on the ranges of these shape parameter learned. The three kinds of the wear debris had a different pattern characteristics and recognized the moving condition and materials very well by neural network.

Operating Condition Diagnosis of the Lubricated Machine Moving Surface by Image Analysis (화상해석에 의한 기계윤할 운동면의 작동상태 진단)

  • 박흥식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.79-87
    • /
    • 1999
  • The most part of the faculty drop a trouble and damage of machine equipment even if whatever cause they break out take place at local and trifling place and the factor dominating their trouble is due to wear debris occurred in the lubricated machine moving surface. This study has been car-ried out to identify morphology of wear debris on the lubricated machine moving system by means of computer image analysis. Namely the wear debris contained in lubricating oil extracted from movable machine equipment will be filtered through membrane filter(void diameter 0.45${\mu}m$) and will be analyzed with its data information such as 50% volume diameter aspect roundness and reflectivity. Morphological characteristic of wear debris is easily distinguished by four shape parameters it is necessary to divide small class of every 100 wear debris in total wear particles in order to distinguish morphological characteristic of wear debris more easily by computer image analysis. We are sure that operation condition diagnosis of the lubricated machine moving surfaces is possible by computer image analysis.

  • PDF

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION (열화 진단 평가를 위한 직류 누설법의 활용)

  • Lee, Kwan-Woo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

A Hybrid Knowledge Model for Structural Monitoring and Diagnosis (구조물 모니터링 및 진단을 위한 지식모델의 개발)

  • 김성곤
    • Computational Structural Engineering
    • /
    • v.9 no.2
    • /
    • pp.163-171
    • /
    • 1996
  • A hybrid knowledge model which amalgamates an object-oriented modeling approach and logic programming implementation is presented for structural health monitoring and diagnosis of instrumented structures. Domain knowledge in structural monitoring and diagnosis is formalized and represented in a logic-based object-oriented modeling environment. The model and environment have been implemented and illustrated in the context of a laboratory case study of damage detection in a successively damaged steel structure.

  • PDF

Acquired Adult Flatfoot: Pathophysiology, Diagnosis, and Nonoperative Treatment (후천적 성인 편평족: 병태생리, 진단과 비수술적 치료)

  • Sung, Ki-Sun;Yu, In-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.3
    • /
    • pp.87-92
    • /
    • 2014
  • Acquired adult flatfoot is a deformity characterized by a decreased medial longitudinal arch and a hindfoot valgus with or without forefoot abduction. The etiologies of this deformity include posterior tibial tendon dysfunction, rheumatoid arthritis, trauma, Charcot's joint, neurologic deficit, and damage to the medial spring ligament complex or plantar fascia. Among these, posterior tibial tendon dysfunction is the most well-known cause. Although posterior tibial tendon dysfunction has been regarded as a synonym of acquired adult acquired flatfoot, failure of the ligaments supporting the arch can also result in progressive deformity even without a posterior tibial tendon problem. The authors describe the pathophysiology, diagnosis, and nonoperative treatment of acquired adult flatfoot, focusing on posterior tibial tendon dysfunction.

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N (열화 진단 평가를 위한 직류 누설법의 활용)

  • 이관우;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

Analysis of Magnetic Flux Leakage based Local Damage Detection Sensitivity According to Thickness of Steel Plate (누설자속 기반 강판 두께별 국부 손상 진단 감도 분석)

  • Kim, Ju-Won;Yu, Byoungjoon;Park, Sehwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.53-60
    • /
    • 2018
  • To diagnosis the local damages of the steel plates, magnetic flux leakage (MFL) method that is known as a adaptable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied in this study. To analysis the sensitivity according to thickness of steel plate in MFL method based damage diagnosis, several steel plate specimens that have different thickness were prepared and three depths of artificial damage were formed to the each specimens. To measured the MFL signals, a MFL sensor head that have a constant magnetization intensity were fabricated using a hall sensor and a magnetization yoke using permanent magnets. The magnetic flux signals obtained by using MFL sensor head were improved through a series of signal processing methods. The capability of local damage detection was verified from the measured MFL signals from each damage points. And, the peak to peak values (P-P value) extracted from the detected MFL signals from each thickness specimen were compared each other to analysis the MFL based local damage detection sensitivity according to the thickness of steel plate.

Rapid Diagnosis Systems Using Accelerometers in Seismic Damage of Tall Buildings

  • Tsuchihashi, Toru;Yasuda, Masaharu
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.207-216
    • /
    • 2017
  • Installing accelerometers in a building is an effective way to know how the building shakes when an earthquake happens. In this paper, we will introduce an example of an analysis that captures the acceleration reduction effect of the vibration damping device using data observed by the accelerometer at Roppongi Hills Mori Tower in Minato-ku, Tokyo, during the Great East Japan Earthquake on March 11, 2011. Moreover, as the latest effort, from the standpoint of a developer who builds and operates a number of high-rise buildings in Japan, where frequent earthquakes are experienced, a system for real-time processing of accelerometer data was developed to instantly diagnose the degree of damage to high-rise buildings, and the actual system of earthquake damage health monitoring is discussed. This system is currently in operation in twelve high-rise buildings including Roppongi Hills Mori Tower.