• Title/Summary/Keyword: d-split

Search Result 427, Processing Time 0.023 seconds

The Study of Effects of Variable Parameters on Flame Structure and NOx Emission in Methane/Air Laminar Partially Premixed Flames (메탄/공기 층류 부분 예혼합화염에서 예혼합 정도에 따른 화염구조와 질소산화물의 배출에 미치는 영향에 관한 연구)

  • Oh, Jeong-Seog;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.362-367
    • /
    • 2003
  • It is shown that the effect of variable parameters on flame structures and NOx emissions in the laminar partially premixed methane-air flames with a co-axial Bunsen burner. Objectives of this paper is to understand the effects of flow variables on NOx emissions and the flame structure with OH chemiluminescence, including reconstructed image by abel inversion processing at each conditions. A fuel flowrate of 200 [cc/min] was fixed and the amount of air was varied from 400 to 1200 [cc/min]. The experimental variables were equivalence ratio(${\Phi}$ fuel split percentage(${\sigma}$ and inner tube recess(x/D). Flow conditions were ranged from $1.36{\sim}4.76$(equivalence ratio), $50{\sim}100$(fuel split percentage) and $0{\sim}20$(inner tube recess). NOx analyzer and ICCD camera with a OH filter were used as a main experimental apparatus. In addition, Abel inversion, which is a kind of tomography and valuable to estimate a two-dimensional structure of co-axial flames from cubical information, was employed for combustion diagnostics. Results from this study indicate that the main effects depend on equivalence ratio and next sigma, x/D for NOx production and OH formation. Throughout Abel inversion, we could affirm the maximum position and the tendency of OH radical intensity by variants at five axial heights above the burner exit.

  • PDF

Impact Tensile Properties and Intergranular Fracture Behavior with Strain Rate Variations of Al-M g-X (X = Cr,Si) Alloy

  • Chang-Suk Han;Min-Gyu Chun;Sung-Soon Park;Seung-In Lim
    • Korean Journal of Materials Research
    • /
    • v.34 no.7
    • /
    • pp.330-340
    • /
    • 2024
  • Al-Mg-Si alloys are light weight and have excellent corrosion resistance, and are attracting attention as a liner material for high-pressure hydrogen containers in hydrogen fuel cell vehicles. Because it has excellent plastic hardening properties, it is also applied to car body panel materials, but it is moderate in strength, so research to improve the strength by adding Si-rich or Cu is in progress. So far, the authors have conducted research on the intergranular fracture of alloys with excessive Si addition from the macroscopic mechanical point of view, such as specimen shape. To evaluate their impact tensile properties, the split-Hopkinson bar impact test was performed using thin plate specimens of coarse and fine grain alloys of Al-Mg-X (X = Cr,Si) alloy. The effect of the shape of the specimen on the characteristics was studied through finite element method (FEM) analysis. As a result, it was found that the intergranular fracture of the alloy with excessive Si depended on the specimen width (W)/grain size (d), which can be expressed by the specimen size and grain size. As W/d decreases, the intergranular fracture transforms into a transgranular fracture. As the strain rate increases, the fracture elongation decreases, and the fracture surface of the intergranular fracture becomes more brittle. It was confirmed that intergranular fracture occurred in the high strain rate region even in materials with small grain sizes.

Strain Rate and Temperature Effects on TPO and PP for Enhanced Airbag Deployment Simulation (열가소성 올레핀과 폴리프로필렌 소재의 변형률 속도와 온도에 따른 기계적 특성을 고려한 에어백 전개 시뮬레이션의 정확도 향상)

  • Se-Min Lee;Gyu-Won Kim;Jae-Hyun Ahn;In-Soo Han;Hak-Sung Kim
    • Composites Research
    • /
    • v.37 no.4
    • /
    • pp.325-329
    • /
    • 2024
  • To accurately predict airbag deployment during a collision, the mechanical properties of polymer materials at high strain rates according to temperature should be considered. In this study, the mechanical properties of TPO and polypropylene were measured at high strain rates via split-Hopkinson pressure bar tests under various environmental temperatures ranging from -35 to 85℃. Through this, tensile strength and failure strain were derived for each strain rate. As the polymer phase moves toward the high strain rate region, the β-transition becomes dominant, resulting in a non-linear increase in tensile strength in the Eyring plot. Additionally, an airbag module impact simulation was conducted to verify the effects of strain rate on airbag deployment using the LS-DYNA software. It was found that the TPO and polypropylene airbag deployment could be accurately predicted using the strain-rate-dependent mechanical behavior rather than quasi-static properties alone.

A Study on the Fabrication of the 4 Port In-Phase High Power Combiner (4포트 동위상 고출력 전력결합기의 구현에 관한 연구)

  • Lee, Young-Sub;Jeon, Joong-Sung;Lee, Seok-Jeong;Ye, Byeong-Duck;Kim, Dong-Il;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.289-294
    • /
    • 2002
  • The broadband high power 3-way combiner was designed and fabricated for the digital TV repeater. To achieve increase of the bandwidth and the high power capability, Wilkinson type power divider was adopted in our research. First of all, Wilkinson type power divider of equal-split and unequal-split were combined, and the characteristics of the four port in-phase power combiner was simulated for each thickness of dielectric substrates. As the results of simulation, the power combiner fabricated by using dielectric substrate of 120 mil-thickness has the characteristics as follows: insertion loss of less than -651 dB, reflection coefficient of less than -13 dB, isolation among the output ports of less than -15 dB, and pose difference among the output ports of smiler than 13$^{\circ}$. Therefore, this power combiner was possible to improve the limit of microstrip line width due to high impedance, the problem of power loss due to interaction between strip lines in a high power combiner and narrow bandwidth simultaneously. Furthermore, making broadband and high power could be achieved since the fabricated 3-way combiner has good characteristics of insertion loss, the reflection coefficient, separation between ports, and phase difference.

Effectiveness of an extraoral cold and vibrating device in reducing pain perception during deposition of local anesthesia in pediatric patients aged 3-12 years: a split-mouth crossover study

  • Ashveeta Shetty;Shilpa S Naik;Rucha Bhise Patil;Parnaja Sanjay Valke;Sonal Mali;Diksha Patil
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.6
    • /
    • pp.317-325
    • /
    • 2023
  • Background: Local anesthetic injections may induce pain in children, leading to fear and anxiety during subsequent visits. Among the various approaches recommended to reduce pain, one is the use of a Buzzy BeeTM device that operates on the concept of gate control theory and distraction. The literature regarding its effectiveness during the deposition of local anesthesia remains limited; hence, the aim of the present study was to determine the efficacy of extraoral cold and vibrating devices in reducing pain perception during the deposition of local anesthesia. Methods: A split-mouth crossover study in which 40 children aged 3-12 years requiring maxillary infiltration or inferior alveolar nerve block for extractions or pulp therapy in the maxillary or mandibular posterior teeth were included. The control intervention involved the application of topical anesthetic gel for one minute (5% lignocaine gel), followed by the administration of local anesthetic (2% lignocaine with 1:80,000 adrenaline) at a rate of 1 ml/ minute. Along with the control protocol, the test intervention involved using the Buzzy BeeTM device for 2 minutes before and during the deposition of the local anesthetic injection. The heart rate and face, legs, arms, cry, and consolability revised (FLACC-R) scale scores were recorded by the dentist to assess the child's pain perception. Results: The mean age of the participants in Group A and Group B was 7.050 ± 3.12 years and 7.9 ± 2.65 years respectively. A reduction in the mean heart rate and FLACC-R score was observed during the deposition of local anesthetic solution in the tissues when the Buzzy BeeTM was used in both groups at different visits in the same subjects (P < 0.05) The Buzzy BeeTM device was effective in reducing the heart rate and FLACC-R scores when used during maxillary infiltration and inferior alveolar nerve block local anesthesia techniques (P < 0.05). Conclusion: The use of extraoral cold and vibrating devices significantly reduces pain perception during local anesthetic deposition in pediatric patients. Considering the results of this study, the device may be incorporated as an adjunct in routine dental practice while administering local anesthesia in children.

DentalVibe reduces pain during the administration of local anesthetic injection in comparison to 2% lignocaine gel: results from a clinical study

  • Joshi, Sagar;Bhate, Kalyani;Kshirsagar, Kapil;Pawar, Vivek;Kakodkar, Pradnya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2021
  • Background: This study was designed to compare the efficacy of DentalVibe against 2% lidocaine gel in reducing pain during the administration of local anesthetic injection in the adult population. Methods: This was a split-mouth open-label, randomized, controlled clinical study conducted in the Department of Oral and Maxillofacial Surgery of a dental institute. Fifty patients who were scheduled for bilateral dental extractions requiring an inferior alveolar nerve block were enrolled in the study. Site A (n = 50) was coated with 2% lidocaine gel followed by a local anesthetic injection, and DentalVibe with local anesthetic injection was used for Site B (n = 50). The primary outcome was pain, which was recorded immediately after the administration of anesthetic injection using the Visual Analogue Scale [VAS 0 - 10]. Results: The VAS pain scores ranged from 4 to 10 for site A and 0 to 6 for site B. Comparison between the two sites showed a statistically significant difference [Mann-Whitney U test value = 51.50, P < 0.001] favoring site B. Conclusion: This study showed that DentalVibe reduces pain during injection of local anesthesia compared to topical anesthetic gel.

Controlled Release of Oxyfluorfen from the Variously Complexed Formulations - I. Model Study of Releasing Rate in Paddy Field (수종(數種) 결합제형(結合劑型으)로부터 Oxyfluorfen의 방출제어연구(放出制御硏究) - I. 논 조건(條件)에서의 방출속도(放出速度) 모형연구(模型硏究))

  • Guh, J.O.;Kuk, Y.I.;Chon, S.U.;Kim, D.K.
    • Korean Journal of Weed Science
    • /
    • v.10 no.3
    • /
    • pp.202-206
    • /
    • 1990
  • Field experiment was conducted to develop a model of controlled release of oxyfluorfen by using various split applications. Rice and some weed species was included in this study. The models of split applications were 10-10-0. 10-10-10. 20-20-0, 20-10-10. 20-20-20, 0-40-0, and 0-0-0g/Ha at 3days before transplanting, and 11 days after transplanting, respectively. Rice injury appeared dispeared at 20 g/Ha of oxyfluorfen on low leaf sheath but disappeared at few days. The injury was reduced by split application even at the same rate of application. However, no injury was siginificant at 30 days after transplanting. Barnyardgrass, Monochoria, and arrowhead were most susceptible to oxyfluorfen, but bulruch and most perennial weeds recovered after temporary growth inhibition. Therefore, to develop oxyflourfen for use in rice transplanting of adult rice seedling, split application with reduced rates, and development of expected to be tank-mixed or premixed with other perennial herbicides to obtain droad spectrum of weeds.

  • PDF

Error Resilient Video Coding Techniques Using Multiple Description Scheme (다중 표현을 이용한 에러에 강인한 동영상 부호화 방법)

  • 김일구;조남익
    • Journal of Broadcast Engineering
    • /
    • v.9 no.1
    • /
    • pp.17-31
    • /
    • 2004
  • This paper proposes an algorithm for the robust transmission of video in error Prone environment using multiple description codingby optimal split of DCT coefficients and rate-distortionoptimization framework. In MDC, a source signal is split Into several coded streams, which is called descriptions, and each description is transmitted to the decoder through different channel. Between descriptions, structured correlations are introduced at the encoder, and the decoder exploits this correlation to reconstruct the original signal even if some descriptions are missing. It has been shown that the MDC is more resilient than the singe description coding(SDC) against severe packet loss ratecondition. But the excessive redundancy in MDC, i.e., the correlation between the descriptions, degrades the RD performance under low PLR condition. To overcome this Problem of MDC, we propose a hybrid MDC method that controls the SDC/MDC switching according to channel condition. For example, the SDC is used for coding efficiency at low PLR condition and the MDC is used for the error resilience at high PLR condition. To control the SDC/MDC switching in the optimal way, RD optimization framework are used. Lagrange optimization technique minimizes the RD-based cost function, D+M, where R is the actually coded bit rate and D is the estimated distortion. The recursive optimal pet-pixel estimatetechnique is adopted to estimate accurate the decoder distortion. Experimental results show that the proposed optimal split of DCT coefficients and SD/MD switching algorithm is more effective than the conventional MU algorithms in low PLR conditions as well as In high PLR condition.

Design of a Frequency Selective Surface Using DSRRs (DSRR을 이용한 주파수 선택적 표면 설계)

  • Woo, Dae-Woong;Kim, Jae-Hee;Ji, Jeong-Keun;Kim, Gi-Ho;Seong, Won-Mo;Park, Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.194-201
    • /
    • 2010
  • We propose a frequency selective surface(FSS) using double split ring resonators(DSRRs) for isolation enhancement between CDMA and RFID. The structure consists of an outer SRR and an inner SRR, and the gaps are formed in the same direction. By properly adjusting the gap and line width, the resonant frequency and skirt characteristics can be adjusted without varying the unit cell size. The proposed structure has a different field distribution from that of an ordinary SRR for magneto-dielectric materials. One layer consists of $9{\times}9$ unit cells and the other layer was separated by 50 mm. To validate the simulation results, we fabricated the patch antenna and the FSSs, and the measured results show a good agreement with the simulated ones. The electrical size of the unit cell is $0.110\;{\lambda}{\times}0.110\;{\lambda}{\times}0.002\;{\lambda}$, and the size of the two layer FSS is $1.058\;{\lambda}{\times}1.058\;{\lambda}{\times}0.153\;{\lambda}$. The two layer FSS maintain gain in CDMA frequency and has 6.9 dB reduced gain in RFID frequency.

A Study on the effects of CSRR-metamaterial on Microstrip Comb-line Array Antennas (마이크로스트립 콤 어레이 안테나에서 CSRR-메타물질의 영향에 관한 연구)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.187-192
    • /
    • 2017
  • We investigated the effects of the CSRR-metamaterial on microstrip comb-line array antennas. Microstrip comb-line array antennas was designed with 12 radiators, gain of 16.09dBi and bandwidth of 0.24GHz in the 24GHz ISM band. The designed antenna had radiation beam perpendicular to the antenna plane, co-polarization gain of 16.09dBi and cross-polarization gain of -10.86dBi. the CSRR-metamaterial increased largely the impedance bandwidth of the antenna from 0.24GHz to 3.6GHz. however as co-polarization gain became 10.08dBi and cross-polarization gain became 14.1dBi, co-polarization was mixed with cross-polarization. And the antenna gain lowered by 1.99dB. On the investigation of the dependence on the split-direction of the CSRR rings, it showed nearly the same characteristics for up-splitted ring used case and down-splitted ring used case. However in the case of arranging up-splitted ring and down-splitted ring in alternation, co-polarization gain decreased to -1.29dBi and cross-polarization gain increased to 13.9dBi, which meant the wave was transited to cross-polarization majority wave.