• Title/Summary/Keyword: d-q Transformation

Search Result 63, Processing Time 0.041 seconds

Active Frequency with a Positive Feedback Anti-Islanding Method Based on a Robust PLL Algorithm for Grid-Connected PV PCS

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.360-368
    • /
    • 2011
  • This paper proposes an active frequency with a positive feedback in the d-q frame anti-islanding method suitable for a robust phase-locked loop (PLL) algorithm using the FFT concept. In general, PLL algorithms for grid-connected PV PCS use d-q transformation and controllers to make zero an imaginary part of the transformed voltage vector. In a real grid system, the grid voltage is not ideal. It may be unbalanced, noisy and have many harmonics. For these reasons, the d-q transformed components do not have a pure DC component. The controller tuning of a PLL algorithm is difficult. The proposed PLL algorithm using the FFT concept can use the strong noise cancelation characteristics of a FFT algorithm without a PI controller. Therefore, the proposed PLL algorithm has no gain-tuning of a PI controller, and it is hardly influenced by voltage drops, phase step changes and harmonics. Islanding prediction is a necessary feature of inverter-based photovoltaic (PV) systems in order to meet the stringent standard requirements for interconnection with an electrical grid. Both passive and active anti-islanding methods exist. Typically, active methods modify a given parameter, which also affects the shape and quality of the grid injected current. In this paper, the active anti-islanding algorithm for a grid-connected PV PCS uses positive feedback control in the d-q frame. The proposed PLL and anti-islanding algorithm are implemented for a 250kW PV PCS. This system has four DC/DC converters each with a 25kW power rating. This is only one-third of the total system power. The experimental results show that the proposed PLL, anti-islanding method and topology demonstrate good performance in a 250kW PV PCS.

A control method and test results of utility interactive photovoltaic power generation systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 안교상;임희천;황인호;주형준
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

New Permanent Magnet Synchronous Motor Current Sensing Phase Delay Compensation Method

  • Park, Sei-Hun;Kim, Il-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.241-246
    • /
    • 2016
  • This paper presents a method that can improve the performance of permanent magnet synchronous motor current control by minimizing the measured current phase delay caused by the Low Pass Filter(LPF) used to cut off the noises that flowed in when feedback currents are measured. Although existing methods that change the Cutoff Frequency of the LPF can minimize phase delays during high speed rotations, their noise cutoff effects are much lower and this may lead to the decline of control performance. Therefore, in this study, an algorithm that can compensate current phase delays through relatively simple calculations from the synchronous motor d-q axis coordinate transformation matrix and the inverse transformation matrix is proposed and the validity of the proposed method is verified by comparing the waveform of the calculated current with the waveform of actual currents through simulations and experiments.

The Modelling and Characteristic Analysis of Brushless Synchronous Motor with Sinusoidal back EMF (정현파 역기전력 특성을 갖는 브러시리스 동기전동기의 모델링 및 특성해석)

  • Kim, Il-Nam;Baek, Su-Hyeon;Kim, Cheol-Jin;Maeng, In-Jae;Yun, Sin-Yong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.380-386
    • /
    • 2000
  • This paper presents the mathematical modelling analysis of Brushless Synchronous Motor(BLSM). The dynamic and the steady state characteristics of BLSM are simulated and analyzed : electromagnetic torque, speed, line voltage, and current. We used mathematical modelling to model of BLSM with sinusoidal back EMF, namely the shaft transformation referencing rotor frame from a, b, c three to produce constant torque like synchronous motor. The experiment result has already similar to compare with simulation result : torque error about 7%, speed error about 5%. The validity of proposed modelling and analysis was confirmed by the experimental result.

  • PDF

Enhanced Phase Angle Detect Method Using High-pass Filter (고주파 필터를 이용한 개선된 위상각 검출 방법)

  • Heo, Min-Ho;Song, Sung-Gun;Kim, Gwang-Heon;Nam, Hae-Gon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

Comparative Study of Field-Oriented Control in Different Coordinate Systems for DTP-PMSM

  • Zhang, Ping;Zhang, Wei;Shen, Xiaofeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.330-335
    • /
    • 2013
  • This paper performs two kinds of Field-Oriented Control (FOC) for dual three phase permanent magnet synchronous motor (DTP-PMSM).The first is based on vector space decomposition to study the effect of current harmonics on electromechanical energy conversion. And the second presents the coupling relations between two sets of windings using two d-q transformation. And then this paper has deeply studied the differences between these two strategies, the different effect on the control of harmonic current and the reason for these differences. MATLAB-based Simulation studies of a 3KW DTP-PMSM are carried out to verify the analysis of differences between the two FOC strategies.

Multichannel Quantum Defect Study of the Perturber's Effect on the Overlapping Resonances in Rydberg Series for the Systems Involving 2 Closed and Many Open Channels

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1669-1680
    • /
    • 2010
  • The phase-shifted version of the multichannel quantum-defect theory (MQDT) was reformulated by disentangling the interloper spectrum from the perturbed dense Rydberg series for a systems involving 2 closed and more than 1 open channel. The theory was applied successfully to Martins and Zimmermann's photoionization spectra of the Rydberg series Cu I $3d^9\;4s(^1D_2)\;nd^2G_{9/2}$ perturbed by the interloper, $3d^9\;4p^2\;^4F_{9/2}$, for which Cohen's 4 channel QDT had failed. The zero surface graphic of the perturbed Fano's asymmetry parameter q of the autoionization spectrum of dense Rydberg series by the interloper was determined by only two parameters for this system. It was used as a map to trace the transformation route of the 3 channel autoionization spectra to the 4 channel spectra when the channel coupling of the closed channels with a newly added open channel was turned on progressively.

A Control Method and Test Results of Utility-Interactive Photovoltaic Power Generation Systems (계통연계 태양광발전시스템의 제어기법 및 연계운전특성)

  • 황인호;안교상;임희천;김신섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.123-129
    • /
    • 2000
  • This paper desclibes a design method and test results of grid-connected photovoltaic power 당eneration s systems, which consists of solar cells, DCI AC inverter, utility grid. A 50 kW photovoltaic power generation s system including a 3-phase DCI AC inverter is designed and made in order to investigate the system l pelionnance for glid connection. Also the control scheme of a three phase cmrent-controlled PWM inverter W with PI controller is presented by using d-q transformation. The experimental waveforms show that the p proposed system has stable behavior with em unit power factor in utility-interactive operation.

  • PDF

A Study on a KTP Crystal Laser System for a Cancer Using P.D.T. (KTP 크리스탈을 이용한 PDT용 레이저 시스템 개발)

  • Kim, Byoung-Mun;Nam, Hyo-Duk;Kim, Byoung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.631-634
    • /
    • 2004
  • The method that exists in Photodynamic Therapy uses Photosensibility drug strongly Influencing tumour accumulation together with photochemical laser effect and makes the structure of tumour be localized and become extinct. The intracavity transformation of the Nd :YAP main radiation 1079 nm was Raman converted in barium nitrate crystal and the Stokes frequency (1216 nm) was doubled using KTP or RTA crystals. The LiF or Cr:YAG crystals are used for the Q-switch. The radiation Parameters were obtained at 100 Hz pump repetition frequency. The average power at 608 nm radiation with LiF and KTP was 700 mW at multi-mode generation. The 3-6 single 10-15 ns pulses were generated during one cycle of pumping. The doubling efficiency with RTA was two times more than with KTP. The cells of Ehrlich adenocarcinoma (0.1 ml) were i.m. implanted in hind thighs of ICR white non-imbred mice. The cells were preliminarily diluted in medium 199 in the ratio of 1 to 5. HpD was intravenous administered in a dose of 10 mg/kg. The left clean-shaven hind leg was irradiated with laser light 21-27 hours after the administration of the preparation. The right non-Irradiated leg of each animal served as a control. The animals with the transplanted tumor that were not injected with HpD sewed as a control to estimate the complex effect (HpD+ irradiation). Before the administration of HpD and on 3 and 4 days after irradiation the tumor size was measured and the percent of the tumor growth inhibition was calculated. The results of animal treatments has shown high efficiency of PDT method for cancer treatment by means 0.608 m high power pulse solid state laser.

  • PDF

Speed Sensorless Control of PMSM Using Direct Torque Control (직접 토크 제어를 사용한 영구자석 동기전동기의 센서리스 속도제어)

  • Shin, S.S.;Kim, S.K.;Lee, D.H.;Kwon, Y.A.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.978-980
    • /
    • 2000
  • Sensorless PMSM is much studied for the industrial applications and home appliances because, a mechanical sensor reduces reliability and increases cost. Two types of instantaneous torque controls are basically used for high performance variable-speed a.c. drive : vector control and direct torque control. This paper investigates speed sensorless control of PMSM using direct torque control. The switching of inverter is determined from SVPWM realizing the command voltage which is obtained by flux error and measured current without d-q transformation. The rotor speed is estimated through adaptive observer with feedback loop. The simulation and experimental results indicate good performances.

  • PDF