• Title/Summary/Keyword: d-Spacing

Search Result 684, Processing Time 0.033 seconds

Preparation of Porous Graphite by Using Template of Co- and Ni-Magadiite (Co, Ni 마가다이트 주형을 이용한 다공성 흑연의 합성)

  • Jeong Soon-Yong
    • Journal of Powder Materials
    • /
    • v.12 no.2 s.49
    • /
    • pp.151-158
    • /
    • 2005
  • Porous graphite was synthesized by removal of template in HF after pyrolysis of pyrolyzed fuel oil (PFO) at $900^{\circ}C$ using the template of Co or Ni intercalated magadiite. Porous graphite had a plate structure like template, and d-spacing value of about 0.7 nm. The extent of crystallization of porous graphite was dependent on the contents of Co or Ni intercalated in interlayer. It can be explained that the metal such as Co and Ni acts as a promotion catalyst for graphite formation. Porous graphite shows the surface area of $328\sim477 m^2/g$.

Fabrication and analysis of the dielectric particle separator (유전 입자 분리기의 제작 및 해석)

  • Yang, Sung-Dong;Lee, Sang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.425-427
    • /
    • 1994
  • A manipulator which can separate dielectric particles (biological cells) was fabricated on a silicon wafer using polyimide and n-type electroplating. It consists of 1024 electrode arrays ($60{\mu}m{\times}60{\mu}m$) and spacing insulator. Positive dielectrophoresis is used for attracting particles. We have the solution of 3-D laplace equation about this device and calculate the force acting on the particles. The solution has spatial periodicity in the x, y directions and decays exponentially in the z direction.

  • PDF

A Study of Electrolytic Ozone Generator for Ozone Asher (Ozone Asher용(用) Ozone Generator 개발연구(開發硏究))

  • Moon, Jae-Duk;Woo, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.648-651
    • /
    • 1993
  • A parallel plate type electrolytic ozone generator for ozone asher has been fabricated and studied, and 4 kinds of ozone generation anode electrode having different slits have also been investigated. It is found that there were optimum conditions for the slits of electrode, which, however, controls the field in the interelectrode spacing, and allows sideflow waterpaths through the slits in the electrode. As a result, the generated ozone concentrations of A, B, C and D type electrode showed 2.2, 1.3, 1.5 and 3.0 ppm for 400 ml/min flowrate tap water test, and, ozone yields of 11, 13, 15 and 30 $mg/kWhcm^2$ respectively.

  • PDF

FE-Simulation on drawing process of $Al-1\%Si$ bonding wire considering influence of fine Si particle (미세 Si 입자의 영향을 고려한 $Al-1\%Si$ 본딩 와이어의 신선공정해석)

  • Hwang W. H.;Moon H. J.;Ko D. C.;Kim B. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.393-396
    • /
    • 2005
  • This paper is concerned with the drawing process of $Al-1\%Si$ bonding wire. In this study, the finite-element model established in previous work was used to analyze the effect of various forming parameters, which included the reduction in area, the semi-die angle, the aspect ratio, the inter-particle spacing and orientation angle of the fine Si particle in drawing processes. The finite-element results gave the consolidation condition. From the results of analysis, the effects of each forming parameter were determined. It is possible to obtain the Important basic data which can be guaranteed in the fracture prevention of $Al-1\%Si$ wire by using FE-Simulation.

  • PDF

Wind loads on a solar array

  • Kopp, G.A.;Surry, D.;Chen, K.
    • Wind and Structures
    • /
    • v.5 no.5
    • /
    • pp.393-406
    • /
    • 2002
  • Aerodynamic pressures and forces were measured on a model of a solar panel containing six slender, parallel modules. Of particular importance to system design is the aerodynamically induced torque. The peak system torque was generally observed to occur at approach wind angles near the diagonals of the panel ($45^{\circ}$, $135^{\circ}$, $225^{\circ}$ and $315^{\circ}$) although large loads also occurred at $270^{\circ}$, where wind is in the plane of the panel, perpendicular to the individual modules. In this case, there was strong vortex shedding from the in-line modules, due to the observation that the module spacing was near the critical value for wake buffeting. The largest loads, however, occurred at a wind angle where there was limited vortex shedding ($330^{\circ}$). In this case, the bulk of the fluctuating torque came from turbulent velocity fluctuations, which acted in a quasi-steady sense, in the oncoming flow. A simple, quasi-steady, model for determining the peak system torque coefficient was developed.

MAGNETISM OF NANOCOMPOSITE CoSm-BASED FILMS

  • Shan, Z.S.;Liu, Y.;Jeong, S.Y.;Zhang, Y.B.;Al-Omari, I.A.;Sellmyer, D.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.702-709
    • /
    • 1995
  • In this paper we review recent work in our laboratory on nanocomposite CoSm-based films including CoSm with Cr underlayer (CoSm//Cr), exchange-coupled magnetic films consisting of CoSm and FeCo layers (CoSm/FeCo), and CoSm multilayers with nonmagnetic spacing layers of SmO (CoSm/SmO). The emphasis is on detailed investigations of microstructure and magnetic properties for CoSm//Cr films, exchange-spring effects for CoSm/FeCo films, and interlayer effects for (CoSm/ SmO) multilayers.

  • PDF

Characterization of Vortex Advection from a Synthetic Jet Impinging on a Wall (충돌 합성 제트의 와류 이송 특성 분석)

  • Kim, MuSeong;Lee, HoonSang;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.39-47
    • /
    • 2019
  • Impingement cooling utilizing synthetic jets is emerging as a popular cooling technique because of its high local cooling efficiency. The interaction between the vortex structure of the synthetic jet and the surface is crucial in understanding the mechanism of this technique. In this study, the impinging vortex structure and its advection are investigated by experiments with jet-to-surface spacing $2{\leq}H/D{\leq}7$, and synthetic jet Reynolds number $5120{\leq}Re{\leq}9050$. Using phase-locked particle image velocimetry, ensemble averaged (phase averaged) flow fields are obtained, and vortex identification and quantification techniques are applied. The shape, trajectory, and intensity change of the vortex are assessed. A sharp decline in the vortex intensity and the occurrence of a counter-rotating vortex at the impingement point are observed.

3D Model Generation and Accuracy Evaluation using Unmanned Aerial Oblique Image (무인항공 경사사진을 이용한 3차원 모델 생성 및 정확도 평가)

  • Park, Joon-Kyu;Jung, Kap-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.587-593
    • /
    • 2019
  • The field of geospatial information is rapidly changing due to the development of sensor and data processing technology that can acquire location information. And demand is increasing in various related industries and social activities. The construction and utilization of three dimensional geospatial information that is easy to understand and easy to understand can be an essential element to improve the quality and reliability of related services. In recent years, 3D laser scanners are widely used as 3D geospatial information construction technology. However, 3D laser scanners may cause shadow areas where data acquisition is not possible when objects are large in size or complex in shape. In this study, 3D model of an object has been created by acquiring oblique images using an unmanned aerial vehicle and processing the data. The study area was selected, oblique images were acquired using an unmanned aerial vehicle, and point cloud type 3D model with 0.02 m spacing was created through data processing. The accuracy of the 3D model was 0.19m and the average was 0.11m. In the future, if accuracy is evaluated according to shooting and data processing methods, and 3D model construction and accuracy evaluation and analysis according to camera types are performed, the accuracy of the 3D model will be improved. In the point cloud type 3D model, Cross section generation, drawing of objects, and so on, it is possible to improve work efficiency of spatial information service and related work.

A Feedforward High Power Amplifier with Loops that can Reduce RX Band Noise as well as Intermodulation Distortion Signals (수신 대력 잡음과 혼변조 왜곡 신호 제거 루프를 갖는 Feedforward 대전력 증폭기 설계)

    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.308-315
    • /
    • 2001
  • In this paper, a new power amplifier is proposed for reduction of amplified RX band noise signals as well as intermodulation distortion signals using feedforward technique. This power amplifier is implemented for IMT-2000 basestation TX frequency band. Both TX band intermodulation distortion signals and RX band noise signals are reduced by controlling variable attenuator, phase shifter and error amplifier. The proposed power amplifier, which contains two loops-intermodulation distortion signals cancellation loop and RX band noise signals cancellation loop, can provide duplexer with low TX path insertion loss for various wireless communication systems due to choice of loose RX attenuation characteristic. The principle of the proposed amplifier is described graphically based on the conceptual schematic diagram. A two-tone test for power amplifier is done at 2.14GHz with frequency spacing of 5MHz, and RX band rejection test is done over RX full band of 60MHz with 1.95GHz center frequency. Experimental results represent that the cancellation performance of intermodulation distortion signals and RX band noise signals are more than 3 1dB and 21dB, respectively.

  • PDF

Monostatic RCS Measurement for Dielectric Barrier Discharge Plasma (유전체 장벽 방전 플라즈마의 Monostatic 레이다 단면적 측정)

  • Lee, Hyunjae;Jung, Inkyun;Ha, Jungje;Shin, Woongjae;Yang, Jin Mo;Lee, Yongshik;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • In this paper, reduction of monostatic RCS by DBD plasma is measured. For the calibration of monostatic RCS, S-parameters of two metallic plate in different sizes are used and the result is within 0.4 dB error. Metallic plate is put behind DBD plasma generator for measuring reduction of monostatic RCS by DBD plasma. To prevent arc discharge between metallic plate and DBD plasma generator, measurement is progressed spacing the interval between metallic plate and DBD plasma generator. As a result, maximum reduction of monostatic RCS is about 3 dB at 7.4 GHz.