• Title/Summary/Keyword: cylindrical chamber

Search Result 160, Processing Time 0.023 seconds

Influences of Injector Nozzle Shape on Nozzle Internal Flow and Outlet Characteristics (인젝터 노즐 형상이 노즐 내부 유동 및 출구 특성에 미치는 영향)

  • Kim, Changhyun;Lee, Kangsoo;Park, Jaein;Baek, Jehyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.108-116
    • /
    • 2013
  • Diesel engine injector is used for spraying the fuel into the cylinder chamber. Complex phenomenon like cavitation occurs from small scale domain, highly pressurized condition and rapid injection. Flow inside the nozzle affects the whole engine performance including combustion and exhaust, therefore understanding the flow inside the injector nozzle is very important. In this paper, cylindrical and convergent-divergent nozzles are suggested for nozzle types and their influences on nozzle internal flow and nozzle outlet characteristics will be analyzed by changing their outlet diameters.

An Analytical Model of Corona Discharge Plasmas in Coaxial Cylindrical Reactor (동축 원통형 코로나 방전 플라즈마의 해석적 모델)

  • 고욱희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.157-161
    • /
    • 2004
  • We present a simple analytical expression of plasma density by making use of the electron density equation to study the dynamic behavior of the corona discharge plasma. It assumes that a specified voltage profile is fed through the inner conductor of the reactor chamber consisting of two coaxial conducting cylinders. The analytical description is based on the electron continuity equation with ionization and attachment by electrons. It is found that the electron density profile calculated between two coaxial cylindrical electrodes depends very sensitively on the Profile of applied voltage. The analytical expression of plasma density and its generation will provide important scaling laws in the corona discharge plasma.

Morphology of Lithothamnion japonicum (Hapalidiaceae, Rhodophyta): A New Record of Coralline Species from Korea

  • Jeong, So Young;Won, Boo Yeon;Cho, Tae Oh
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.3
    • /
    • pp.319-328
    • /
    • 2018
  • The morphology, anatomy and reproduction (tetra/bisporic and male) of Lithothamnion japonicum Foslie was studied, using holotype material and materials collected from Korea. Lithothamnion japonicum is characterized based on the presence of encrusting, warty to fruticose thallus, branched or unbranched short and cylindrical protuberances, conical shaped spermatangial conceptacles, branched (dendroid) spermatangial systems formed on floor, walls, and roof of conceptacle chamber, cylindrical shaped spermatangial conceptacle canal, 9-10 cell layered spermatangial conceptacle roof, raised tetra/bisporangial conceptacles without rims, flattened tetra/bisporangial conceptacle pore plate, 16-50 pores on each pore plate, 6-8 rosette cells surrounded by each pore, pore canal lining filaments composed of tetra/bisporangial conceptacle roof, and buried senescent tetra/bisporangial conceptacles completely infilled with relatively large and irregularly arranged calcified sterile cells. In this study, we report a new record of Lithothamnion japonicum from Korean coasts.

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Numerical and Experimental Analyses Examining Ozone and Limonene Distributions in Test Chamber with Various Turbulent Flow Fields

  • ITO, Kazuhide
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.3
    • /
    • pp.89-99
    • /
    • 2008
  • Indoor ozone has received attention because of its well-documented adverse effects on health. In addition to the inherently harmful effects of ozone, it can also initiate a series of reactions that generate potentially irritating oxidation products, including free radicals, aldehydes, organic acids and secondary organic aerosols (SOA). Especially, ozone reacts actively with terpene. The overarching goal of this work was to better understand ozone and terpene distributions within rooms. Towards this end, the paper has two parts. The first describes the development of a cylindrical test chamber that can be used to obtain the second order rate constant $(k_b)$ for the bi-molecular chemical reaction of ozone and terpene in the air phase. The second consists of model room experiments coupled with Computational Fluid Dynamics (CFD) analysis of the experimental scenarios to obtain ozone and terpene distributions in various turbulent flow fields. The results of CFD predictions were in reasonable agreement with the experimental measurements.

Experimental Study of High-Altitude Simulation using Small-Scale Supersonic Diffuser (소형 초음속 디퓨저를 이용한 고고도환경 모사에 대한 시험적 연구)

  • Lee Ji-Hyung;Oh Jong-Yun;Byun Jong-Ryul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.138-145
    • /
    • 2004
  • Experimental study was conducted on cylindrical supersonic diffuser in order to investigate the effects of the ratios of diffuser area to nozzle throat area (Ad/At), diffuser area to nozzle exit area (Ad/Ae), nozzle exit area to its throat area (Ae/At), and diffuser length to its diameter (L/D), the free volume of vacuum chamber, and the relative distance between nozzle exit and diffuser inlet on the diffuser performance. The study showed that the minimum diffuser starting pressure (Po/Pa)st increased monotonically with increase in (Ad/At) as predicted by the normal shock and momentum theory models and the volume of vacuum chamber affected vacuum pressure level during diffuser operation at lower value of (Ad/Ae). The results of this investigation will be utilized in the design of real-scale high-altitude simulation test facility.

Behavior of Lateral Loaded Piles with Pile shape and Length (말뚝형태 및 길이변화를 고려한 수평재하말뚝의 거동특성)

  • Hwang, Sung-Wook;Kim, Min-Kee;Kyung, Du-Hyun;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1125-1131
    • /
    • 2008
  • In this study, Calibration Chamber Tests for cast-in-place piles in sand were performed for measuring behavior properties of piles. These tests were examined effects of various parameters of soil conditions including the relative density($D_R$), the coefficient of earth pressure, and investigated differences between cylindrical pile and taper-shaped pile with the same volumes. The important effect factors of foundation behavior were investigated by considering embedded depth of piles and shapes of piles, and inspected details of lateral behavior of piles. These results were verified reliabilities of each methods for comparing the results estimated with tests and the results by proposed estimating solutions in the past.

  • PDF

Free Vibration Analysis of the Scroll Compressor Housing by Shell Theory (셸이론을 이용한 스크롤 압축기 하우징의 자유진동해석)

  • Kim, H.S.;Lee, Y.S.;Yang, M.S.;Choi, M.H.;Ryu, C.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.242-247
    • /
    • 2000
  • In this study, the Rayleigh's energy method and the Rayleigh-Ritz method on the basis of Flugge's shell theory was used to analyze the dynamic characteristics of the scroll compressor housing with clamped boundary condition. The frequencies and mode shapes from theoretical calculation were compared with those of commercial finite element code, ANSYS. In order to validate the theory, modal test was also performed by impact test and FFT analysis.

  • PDF

The Insulation Characteristics by Conducting Particle in GIS (GIS내 금속이물 존재시 절연특성)

  • Cho, Kook-Hee;Kim, Jae-Chul;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.105-108
    • /
    • 2004
  • This paper describes the influence of conducting particle in the coaxial cylindrical electrodes under alternating voltage condition investigated using breakdown electric field and electro magnetics simulation method. Simulated particle-location in GIS chamber were the particle on electrode, the particle on enclosure and free moving particle. As results, it was founded that in case of breakdown electric field of the GIS chamber, breakdown electric field of particle on electrode was the lowest, that of free moving particle was middle and that of particle on enclosure was the highest. And in case of the electric field analysis with particle locations, electric field of particle on electrode was the highest that of lifted particle was middle and that of particle on enclosure was the lowest. This results can offer a practical reference ra the insulation design of domestic GIS.

  • PDF

Combustion Characteristics of Methane-Air Mixture in a Constant Volume Combustion Chamber(3) : Exhaust Emission (정적연소기에서의 메탄-공기 혼합기의 연소특성(3) : 배기배출물)

  • 최승환;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • A cylindrical constant volume combustion chamber was used to investigate the exhaust emission characteristics of homogeneous charge, stratified pattern and inhomogeneous charge under various conditions using gas chromatography. In the case of homogeneous charge condition, the $CO_2$ concentration is proportional to excess air ratio and overall charge pressure, the $CO_2$ concentration is proportional to excess air ratio and the UHC concentration is inversely proportional to ignition time and overall charge pressure. In the case of stratified pattern, the RI(rich injection) condition shows better exhaust emission characteristics, especially $CO_2$, than that of HI (homogeneous injection) or LI (lean injection) conditions. In inhomogeneous charge conditions, when initial charge pressure is increased, $CO_2$ and UHC concentration is reduced but $O_2$ concentration is increased. And when the excess air ratio of initial charge mixture is 3.0, UHC and $CO_2$concentration show lowest values.