• Title/Summary/Keyword: cycling system

검색결과 283건 처리시간 0.028초

소규모 경축순환 유기농가 경영에서의 범위의 경제성 실증 분석 -평창군 'W농장' 사례를 중심으로- (An Empirical Analysis of Economies of Scope in the Small Crop-Livestock Cycling Organic Farming -Case of 'W-farm' in Pyungchang -)

  • 최덕천
    • 한국유기농업학회지
    • /
    • 제24권4호
    • /
    • pp.665-680
    • /
    • 2016
  • Theoretically, it is said that economies of scope can be realized in the cropelivestock cycling organic farming. Thus, it is also used as the principle of organic farming. However, it is difficult to find the cases of the empirical analysis of it in Korea. In that sense, this study is meaningful in that it analyzed the agricultural data of case farms of obtaining the approval of both organic agricultural products and organic animal products and practicing cycling farming for 4 years and tested the hypothesis. This study measured economies of scope by using the actual measurement value and estimation value farming performance statistics for 4 years of case farms. This farmhouse conducted nutrient cycling in the farm like self-manufacturing and injecting organic agricultural byproduct and wild grass as organic livestock feed and fermenting organic livestock manure to organic compost to return it 100%. The results can be summarized as follows: According to the result of cycling farming of combining and producing organic agriculture and organic livestock, economies of scope were found to be realized in this case farmhouse. That is, although not strong, EOS>0, there were economies of scope. The measurement value appeared as 0.0722, 0.00378, 0.04667 and 0.13127 in 2012, 2013, 2014 and 2015, respectively. It was improved as time passes and the scale gets smaller. Therefore, in order to further improve economies of scope, there should be measures of reducing duplication costs between agriculture-livestock as low as possible and lowering the production cost of organic feed. That is, there is a need for the management strategy to adjust the import function and cost function according to the change in management paradigm and cropping system.

3D 스캔을 이용한 사이클 동작 전후 체표 변화 고찰 및 2D 전개 패턴의 비교 (2D Pattern Development of Body Surface from 3D Human Scan Data Using Standing and Cycling Postures)

  • 정연희;이예진
    • 한국생활과학회지
    • /
    • 제21권5호
    • /
    • pp.975-988
    • /
    • 2012
  • Although the pattern development for tight-fitting clothing has been carried out using 3D data on humans, the pattern development using 3D scan data obtained for various postures still remains an interesting subject. In this study, we have developed the 2D pattern using the 3D human body reflecting standing and cycling postures. The 3D scan data of a subject was obtained using Cyberware. 2C-AN program(Triangle simplification and the Runge-Kutta method) was used in the system to reduce the 3D scan data points and to make segmented triangular patches in a plane from 3D data. As results, surface distance and area of each body part of standing and cycling postures were also provided for the future application of the functional clothing construction. The area of center piece on the front (c.front) decreased by $106.45cm^2$(-13.08%) and that of lateral piece(s.back) on the back increased by $144.96cm^2$(18.69%) in the patterns of cycling posture. The girth of neck and waist for the cycling posture increased by 0.88cm (3.92%) and 1.56cm(4.40%) respectively, and the that of thigh decreased by 1.01cm(-2.24%). The differences between the area in the 2D pattern obtained from the 3D scan data and that in the 3D scan surface data for standing and cycling postures were very small($-10.34cm^2$(-0.32%) and $-44.33cm^2$(-1.32%)).

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • 정현주;임주희;이성호;;박수종;육인수
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF

중합효소연쇄반응 기기의 온도 사이클링 제어시스템 설계 (Thermal Cycling Control System Design for Polymerase Chain Reaction(PCR) Machine)

  • 김종해;조용석;오도창
    • 제어로봇시스템학회논문지
    • /
    • 제12권5호
    • /
    • pp.419-424
    • /
    • 2006
  • In this study, a thermal control system which applied a Peltier device for the polymerase chain reaction(PCR) machine is to be designed. Here in order for it to easily follow the characteristics of the thermal cycle existing for gene amplification of the PCR sample, a PCR control board utilizing a thermal sensor, a Peltier, and a 8 bit microprocessor is made up. Especially a fuzzy type PD control algorithm is applied periodically in time response, and control system is implemented. For that matter, the characteristic data of subject system is obtained and analysed to begin with. Based on this analysed data, the proposed control algorithm is applied and an evaluation of the performance of the whole system take place through the PC.

동해 방사성탄소동위원소 연구 현황과 전망 (Current Status and Prospects Regarding Radiocarbon Studies in the East Sea)

  • 김민경
    • Ocean and Polar Research
    • /
    • 제44권1호
    • /
    • pp.99-111
    • /
    • 2022
  • Together with the development of measurement techniques, radiocarbon (14C) has been increasingly used as a key tool to investigate carbon cycling and associated biogeochemistry in the ocean. In this paper, the current status of radiocarbon studies in the East Sea (Japan Sea) is reviewed. Previously, spatiotemporal distribution and change of the water masses in the East Sea from 1979 to 1999 were investigated by using the 14C in the dissolved inorganic carbon (DIC). Researches on sinking particulate organic carbon (POC) revealed that POC in the deep ocean has more complex and heterogeneous origins than we expected. In particular, since 2011, Korean researchers have been collecting sinking particle samples for more than 10 years, so it is expected that 14C of POC will provide important information to understand carbon cycling in relation to climate change. Although the quantity of 14C data published in the East Sea is still limited, the importance and the future direction of using 14C to understand the biogeochemical mechanisms of carbon cycling and its role as a carbon reservoir in the East Sea are detailed herein.

글레이즈 컬러를 적용한 의치상 레진의 비커스 경도 평가 (Evaluation of the Vickers hardness on denture acrylic resins by glaze color)

  • 임용운
    • 대한치과기공학회지
    • /
    • 제44권4호
    • /
    • pp.111-117
    • /
    • 2022
  • Purpose: This study was conducted to compare the Vickers hardness on the denture acrylic resins using the glaze color system. Methods: The specimens (20×2 mm) were prepared by mixing according to the manufacturer's protocols through thermal polymerization and self-polymerization. The surface roughness was measured using a testing machine after water-soaking for 48 hours. For the Vickers hardness measurement, the completed specimen was soaked in water for 48 hours and then applied at 200 gf for 30 seconds. Was the specimen immersed after being soaked in water for 48 hours at temperatures of 5℃ and 55℃, respectively, for 30 seconds for the thermos-cycling treatment, and it was carried out 5,000 times. Results: Surface roughness was higher in the more glazing group than in the control group. A significant difference was observed in all groups, except for the Retec Don 2000 and Luciton 199 groups (p<0.05). As a result of measuring the Vickers hardness, the treatment by glaze color showed slightly lower but the thermo-cycling treatment group appeared higher than control group in all. Conclusion: Therefore, the glaze color was found to affect the surface roughness and showed a significant difference. The surface glaze color showed a very high Vickers hardness after the thermo-cycling treatment, indicating that the surface-strengthening effect is greater in the oral environment.

Enhancement of Quick-Charge Performance by Fluoroethylene Carbonate additive from the Mitigation of Electrode Fatigue During Normal C-rate Cycling

  • Tae Hyeon Kim;Sang Hyeong Kim;Sung Su Park;Min Su Kang;Sung Soo Kim;Hyun-seung Kim;Goojin Jeong
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권4호
    • /
    • pp.369-376
    • /
    • 2023
  • The quick-charging performance of SiO electrodes is evaluated with a focus on solid electrolyte interphase (SEI)-reinforcing effects. The study reveals that the incorporation of fluoroethylene carbonate (FEC) into the SiO electrode significantly reduced the electrode fatigue, which is from the the viscoelastic properties of the FEC-derived SEI film. The impact of FEC is attributed to its ability to minimize the mechanical failure of the electrode caused by additional electrolyte decomposition. This beneficial outcome arises from volumetric stain-tolerant characteristics of the FEC-derived SEI film, which limited exposure of the bare SiO surface during 0.5 C-rate cycling. Notably, FEC greatly improves Li deposition during quick-charge cycles following aging at 0.5 C-rate cycling due to its ability to maintain a strong electrical connection between active materials and the current collector, even after extended cycling. Given these findings, we assert that mitigating SEI layer deterioration, which compromises the electrode structure, is vital. Hence, enhancing the interfacial attributes of the SiO electrode becomes crucial for maintaining kinetic efficiency of battery system.

국산 하이폴 복합레진의 변록누출에 관한 실험적 연구 (MARGINAL LEAKAGE TEST ON HI-POL COMPOSITE RESIN)

  • 임성삼
    • 대한치과의사협회지
    • /
    • 제15권11호
    • /
    • pp.757-761
    • /
    • 1977
  • The purpose of this study was to evaluate the marginal sealing ability of Hipol composite resin. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Hi-pol, Adaptic, Nuvasystem, Epolite and Amalgam was investigated at 37℃ and under temperature cycling between 4℃ and 60℃. The results were as follows; 1. All the filling materials revealed the penetration of dye between cavity walls and restorations. 2. Hi-pol and Adaptic showed more marginal leakage than other materials and the degree of dye penetration in Hi-pol was similar to that of Adaptic. 3. Nuva system showed the least marginal leakage at 37℃ and under temperature cycling between 4℃ and 60℃. 4. Under temperature cycling, all materials showed a slight increase in marginal leakage except Epolite, which showed the greastest change in leakage.

  • PDF

Electrochemical Signal Amplification by Gap Electrodes and Control of Gap Distances

  • Park, Dae Keun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.197-200
    • /
    • 2019
  • We report on electrochemical signal amplification using gap electrodes based on the redox cycling between gap electrodes. The distance between electrodes was controlled from $2{\mu}m$ to a few hundreds of nanometer by chemical deposition of reduced Au ion on the pre-defined electrodes. Enhanced redox current of ferri/ferrocyanide was obtained by redox cycling between the two working electrodes. The faradaic current is amplified about a thousand times in this redox system. Since the signal amplification is due to the shortened diffusion length between the two electrodes, the narrower the nanogap was, the better detection limit, calibration sensitivity, and dynamic range. The experimental results were discussed on the basis of the cyclic voltammetry (CV), atomic force microscope (AFM) and scanning electron microscope (SEM) measurements.