• Title/Summary/Keyword: cyclic act

Search Result 55, Processing Time 0.017 seconds

Survey of Actual Conditions of Material Safety Data Sheet and Quantitative Risk Assessment of Toxic Substances : Substitutes for Degreasing Agents (일부 대체세정제 제조업체의 물질안전보건자료의 실태와 그 화학물질의 유해성 평가에 관한 연구)

  • Yoon, Chong-Guk;Jeon, Tae-Won;Chung, Chin-Kap;Lee, Myung-Hee;Lee, Sang-Il;Cha, Sang-Eun;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • Since the regulation of MSDS (Material Safety Data Sheets) had started from July 1996, employers were required to furnish MSDS for the chemicals in use in their workplace. However, many MSDS did not contain upright information for the chemicals, and they were not updated regularly, and were not written in the standard format required by the Industrial Safety and Health Act (ISHA). The purposes of this study were 1) to examine the reliability of MSDS for mixed solvents, 2) to provide reliable MSDS to employers or employees, 3) to find out any difficulties in implementing MSDS after the initiation, and 4) to promote regular MSDS updating and to ensure the reliability of MSDS for chemical manufacturers. To check the reliability of MSDS of mixed chemicals, 21 samples of mostly degreasing solvents were collected along with their MSDS from the work place. The samples were analyzed by gas chromatography-mass selective detector(GC-MSD). Their components were classified as saturated hydrocarbon, cyclic hydrocarbon, aromatics, and halogen containing hydrocarbon, and the amount of each class were measured. Manufacture's MSDS were compared with the actual composition of the collected samples, and further examined the reliability by checking whether the chemicals analyzed were included in the MSDS correctly. Finally, each item of MSDS was evaluated whether the MSDS correspond to the regulation required by ISHA. The results were following: 1) most of the degreasing solvents in MSDS were incorrect in their composition and contents, 2) the information in the MSDS including hazard classification, exposure level, toxicity, regulatory information were incorrectly provided, and 3) some MSDS did not disclose carcinogens in their MSDS. Continuous monitoring of MSDS was required to ensure reliability of MSDS. The Chemicals containing hydrocarbons from C10-C15 need to be tested to provide toxicity data. In addition, governmental support for providing correct MSDS was recommended to ensure reliability of MSDS. The MSDS regulation relating to the confidential business information may need to be revised to ensure reliability of MSDS.

  • PDF

Effects of Adsorption Sites of the Polycrystalline Ir Surface on Potentially Deposited H (수소 전착에 관한 다결정 Ir표면의 흡착부위 효과)

  • Chun Jang Ho;Mun Kyeong Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.144-149
    • /
    • 1999
  • The two distinct adsorption sites and transition between the under and over-potentially deposited hydrogen (UPD H and OPD H) on the polycrystalline iridium (poly-Ir) surface in the 0.2 M LiOH electrolyte have been studied using the phase-shift method. At the forward and backward scans, the UPD H peak occurs on the cyclic voltam-mogram. The transition region on the phase-shift profile or the Langmuir adsorption isotherm occurs at ca. -0.80 to -0.95 V vs. SCE. At the transition region (-0.80 to -0.95 V vs. SCE), the equilibrium constant (K) for H adsorption transits from $7.9\times10^{-2}\;to\;1.5\times10^{-4}$ and vice versa. Similarly, the standard free energy $({\Delta}G_{ads})$ of H adsorption transits from 6.3 to 21.8kJ/mol and vice versa. The UPD H and OPD H on the poly-Ir surface act as two distinguishable electroadsorbed H species. Both the UPD H peak and the transition region are attributed to the two distinct adsorption sites of the UPD H and OPD H on the poly-Ir surface.

Preliminary Study on Linear Dynamic Response Topology Optimization Using Equivalent Static Loads (등가정하중을 사용한 선형 동적반응 위상최적설계 기초연구)

  • Jang, Hwan-Hak;Lee, Hyun-Ah;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1401-1409
    • /
    • 2009
  • All the forces in the real world act dynamically on structures. Design and analysis should be performed based on the dynamic loads for the safety of structures. Dynamic (transient or vibrational) responses have many peaks in the time domain. Topology optimization, which gives an excellent conceptual design, mainly has been performed with static loads. In topology optimization, the number of design variables is quite large and considering the peaks is fairly costly. Topology optimization in the frequency domain has been performed to consider the dynamic effects; however, it is not sufficient to fully include the dynamic characteristics. In this research, linear dynamic response topology optimization is performed in the time domain. First, the necessity of topology optimization to directly consider the dynamic loads is verified by identifying the relationship between the natural frequency of a structure and the excitation frequency. When the natural frequency of a structure is low, the dynamic characteristics (inertia effect) should be considered. The equivalent static loads (ESLs) method is proposed for linear dynamic response topology optimization. ESLs are made to generate the same response field as that from dynamic loads at each time step of dynamic response analysis. The method was originally developed for size and shape optimizations. The original method is expanded to topology optimization under dynamic loads. At each time step of dynamic analysis, ESLs are calculated and ESLs are used as the external loads in static response topology optimization. The results of topology optimization are used to update the design variables (density of finite elements) and the updated design variables are used in dynamic analysis in a cyclic manner until the convergence criteria are satisfied. The updating rules and convergence criteria in the ESLs method are newly proposed for linear dynamic response topology optimization. The proposed updating rules are the artificial material method and the element elimination method. The artificial material method updates the material property for dynamic analysis at the next cycle using the results of topology optimization. The element elimination method is proposed to remove the element which has low density when static topology optimization is finished. These proposed methods are applied to some examples. The results are discussed in comparison with conventional linear static response topology optimization.

Effects of Cyclosporin A on the Cell Cycle Regulation of Human Gingival Fibroblasts (Cyclosporin A가 치은섬유아세포의 세포주기조절에 미치는 영향)

  • Pi, Sung-Hee;Kim, Dae-kyum;Kim, Tak;You, Yong-Ouk;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.611-623
    • /
    • 2001
  • Cyclosporin A is a cyclic polypeptide produced by the metabolism of fungi. It is widely used at present as immunosuppressive treatment following organ transplants. It is also used to deal with autoimmune diseases such as rheumatoid arthritis or type II diabetes. Gingival hyperplasia is one of the most frequent side-effects associated with the prescription of Cyclosporin A. The mechanisms involved in Cyclosporin A induced gingival hyperplasia are not yet clear. In vitro Cyclosporin A promotes proliferation of gingival fibroblasts, that Cyclosporin A act as a mitogen. Its action is based on mitosis of gingival fibroblasts regulated by cell cycle regulatory proteins. It was the purpose of the present study to examine the effects of Cyclosporin A on human gingival fibroblasts by means of biological and biochemical criteria. In this present study, we examined change of cell proliferation, cell activity, cell viability and cell cycle progression after application of Cyclosporin A. We also examined expression of cell cycle regulatory proteins by western blot analysis. Human gingival fibroblasts were cultured for 48 hours with application of Cyclosporin A at concentrations of 0.01, 0.1, 1, and 10 ng/ml. Cyclosporin A(1 ng/ml) significantly increased the cell activity of gingival fibroblast. Proliferation and viability of gingival fibroblasts were also increased in group treated with 1 ng/ml of Cyclosporin A compared to control group. In the cell cycle analysis, S phase was increased and G1 phase was decreased in the group treated with 1 ng/ml of Cyclosporin A. Cyclosporin A increased the expression of cdk4 and inhibited the expression of pRB and p21. These results suggest that 1 ng/ml of Cyclosporin A may increase the cell cycle progression of human gingival fibroblasts, and its mechanisms may increase the expression of cdk4 and decrease the expression of pRB and p21.

  • PDF

Electrochemical Characteristics of H Adsorption Sites at the Poly-Pt/LiOH Aqueous Electrolyte Interface (다결정 Pt/LiOH 수성 전해질 계면에서 수소 흡착부위의 전기화학적 특성)

  • Chun Jang Ho;Cho Chong Dug
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.213-217
    • /
    • 1999
  • The electrochemical characteristics of two distinct adsorption sites of H at the polycrystalline Pt/0.2 M LiOH aqueous electrolyte interface have been studied using the phase-shift method. At the forward and backward scans, the under-potentially deposited H (WD H) peak occurs on the cyclic voltammogram. The transition region on the phase-shift profile or the Langmuir adsorption isotherm occurs at ca. -0.66 to -0.96 V vs. SCE. At the transition region (ca. -0.66 to -0.96 V vs. SCE), the equilibrium constant (K) for H adsorption transits from 18.5 to $4.0\times10^{-5}$ and vice versa. Similarly, the standard free energy $({\Delta}G_{ads})$ of H adsorption transits from -7.2 to 25.1kJ/mol and vice versa. The under and over-potentially deposited H (UPD H and OPD H) on the poly-Pt surface act as two distinguishable electroadsorbed H species. An exothermic reaction occurs at the UPD H range. Both the UPD H peak and the transition region are attributed to the two distinct adsorption sites of the UPD H and OPD H on the poly-Pt surface.