• Title/Summary/Keyword: cyanoacrylate

Search Result 73, Processing Time 0.027 seconds

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Endovascular Treatment of a Systemic-to-Pulmonary Artery Fistula: A Case Report (체-폐동맥루의 혈관 내 치료: 증례 보고)

  • Eunbyul Lee;Dong Jae Shim;Doyoung Kim;Jung Whee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.682-687
    • /
    • 2021
  • Systemic-to-pulmonary artery fistulas are rare. This condition may be congenital, post-traumatic, or post-inflammatory and can cause infection, hemorrhage, or pulmonary hypertension. Here, we report a case of an intercostal-to-pulmonary artery fistula, incidentally detected during the evaluation of dyspnea in a 67-year-old female. Retrograde transcatheter coil embolization in a dilated draining pulmonary artery was initially attempted. However, another draining pulmonary artery developed after 5 months. The intercostal arteries or systemic feeders were successfully embolized through a transarterial access. At the 10-month follow-up, the abnormally dilated vessels had regressed, and dyspnea had improved. Sequential or simultaneous retro- and antegrade transcatheter embolization may successfully treat pleural arterio-arterial fistulas.

Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations

  • Keun Young Park;Jin Woo Kim;Byung Moon Kim;Dong Joon Kim;Joonho Chung;Chang Ki Jang;Jun-Hwee Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.8
    • /
    • pp.1285-1292
    • /
    • 2019
  • Objective: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. Materials and Methods: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. Results: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). Conclusion: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.

Safety and efficacy comparison of embolic agents for middle meningeal artery embolization for chronic subdural hematoma

  • Nathaniel R. Ellens;Derrek Schartz;Gurkirat Kohli;Redi Rahmani;Sajal Medha K. Akkipeddi;Thomas K. Mattingly;Tarun Bhalla;Matthew T. Bender
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.1
    • /
    • pp.11-22
    • /
    • 2024
  • Objective: To perform a systematic review and meta-analysis evaluating the efficacy of middle meningeal artery embolization in terms of both clinical and radiographic outcomes, when performed with different embolic agents. Methods: A systematic literature review and meta-analysis was performed to evaluate the impact of embolic agents on outcomes for middle meningeal artery (MMA) embolization. The use of polyvinyl alcohol (PVA) with or without (±) coils, N-butyl cyanoacrylate (n-BCA) ± coils, and Onyx alone were separately evaluated. Primary outcome measures were recurrence, the need for surgical rescue and in-hospital periprocedural complications. Results: Thirty-one studies were identified with a total of 1,134 patients, with 786 receiving PVA, 167 receiving n-BCA, and 181 patients receiving Onyx. There was no difference in the recurrence rate (5.5% for PVA, 4.5% for n-BCA, and 6.5% for Onyx, with P=0.71) or need for surgical rescue (5.0% for PVA, 4.0% for n-BCA, and 6.9% for Onyx, with P=0.89) based on the embolic agent. Procedural complications also did not differ between embolic agents (1.8% for PVA, 3.6% for n-BCA, and 1.6% for Onyx, with P=0.48). Conclusions: Rates of recurrence, need for surgical rescue, and periprocedural complication following MMA embolization are not impacted by the type of embolic agent utilized. Ongoing clinical trials may be used to further investigate these findings.

Development of a Discogenic Pain Animal Model: Preliminary Study (추간판성통증 동물모델의 개발: 초기 연구)

  • Kim, Byung-Jo;Lee, Min;Lim, Eun-Jeong;Yu, Sung-Wook;Hong, Sung-Ha;Hong, Seok-Joo;Na, Heung-Sik
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.2
    • /
    • pp.41-47
    • /
    • 2009
  • Background: Discogenic pain can develop into chronic low back pain that is very difficult to treat effectively, because the pathogenesis of the disease still remains controversial. To clarify the pathogenesis, numerous animal models of intervertebral disc degeneration have been proposed in the literature, each with attendant advantages and disadvantages. The aim of this study was to determine the most efficacious method and dose of complete Freund's adjuvant (CFA) injection into intervertebral disc to develop a discogenic pain in a rat. Methods: CFA was injected into the L5-L6 or L4-L5 disc of male Sprague-Dawley rats in various conditions including a dose of CFA (10, 20, or 50 uL), drilling, injection site sealing using cyanoacrylate, and injection velocity. Sham animals were subjected to the same procedure, except for the CFA injection. Mechanical and heat allodynia were serially measured at both hindpaws until 8 weeks post-operatively. Serial MRI analyses were performed to observe degenerative changes of the discs. In addition, CGRP & Substance P-immunoreactivities (ir) in the superficial dorsal horn were evaluated at 4 weeks using immunohistochemistry. Results: Each condition provoked various problems such as development of hindpaw paralysis, CFA leakage, and no pain development. Mid-sagittal T2 MRI revealed no significant degenerative changes in the CFA injected disc. The CGRP-ir of the bilateral superficial dorsal horns at the level of L5-L6 was significantly increased in the CFA group. Conclusions: A total of 10 uL CFA injection into L5-L6 disc for a period of 10 minutes using a 26-gauge needle without drilling was the most efficacious way to develop discogenic pain animal model.

  • PDF

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

Biomimetic characteristics of mussel adhesive protein-loaded collagen membrane in guided bone regeneration of rabbit calvarial defects

  • Song, Woong-Kyu;Kang, Joo-Hyun;Cha, Jae-Kook;Lee, Jung-Seok;Paik, Jeong-Won;Jung, Ui-Won;Kim, Byung-Hoon;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.5
    • /
    • pp.305-316
    • /
    • 2018
  • Purpose: The aim of the present study was to evaluate the biocompatibility and barrier function of mussel adhesive protein (MAP)-loaded collagen membranes in guided bone regeneration (GBR). Methods: Eight male New Zealand white rabbits were used. Four circular defects (diameter: 8 mm) were created in the calvarium of each animal. The defects were randomly assigned to 1) a negative control group, 2) a cyanoacrylate (CA)-loaded collagen membrane group (the CA group), 3) a MAP-loaded collagen membrane group (the MAP group), and 4) a group that received a polycaprolactone block with MAP-loaded collagen membrane (the MAP-PCL group). Specimens were harvested at 2 weeks (n=4) and 8 weeks (n=4) postoperatively for observational histology and histometric analysis. Results: In the histologic analysis, MAP was completely absorbed without any byproducts. In contrast, some of the CA adhesive remained, showing an inflammatory reaction, at 8 weeks. In the MAP-PCL group, the MAP-loaded collagen membranes served as a barrier membrane despite their fast degradation in GBR. No significant difference was found in the amount of new bone between the MAP-PCL and MAP groups ($1.82{\pm}0.86mm^2$ and $2.60{\pm}0.65mm^2$, respectively). Conclusions: The MAP-loaded collagen membrane functioned efficiently in this rabbit calvarial GBR model, with excellent biocompatibility. Further research is needed to assess clinical applications in defect types that are more challenging for GBR than those used in the current model.

Changes of the Renal Arteries According to Various Embolic Materials (다양한 색전물질에 의한 신동맥의 변화)

  • Cho, Jae-Ho;Cho, Kil-Ho;Chang, Jae-Chun;Park, Bok-Hwan;Kim, Dong-Sug
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.1
    • /
    • pp.96-104
    • /
    • 1995
  • The transarterial embolization has been widely used to control bleeding. It has a variety of clinical utility; to reduce bleeding on the surgical field, to reduce the size of malignant tumor as a preopearative treatment, to treat arteriovenous malformation or arterial aneurysm as a curative method and to promote life quality of patient with diffuse or multiple hepatocellular carcinoma as a palliative treatment, etc. With the advance of modem technology, various embolic materials have been also developed. However, it has not been fully investigated of histopathologic changes of the embolized organs according to the embolic materials used. This study was undertaken to investigate the histopathologic changes of embolized renal artery in rabbit by various embolic materials, according to each embolic material and to time passed by after embolization. Of the 5 arteries embolized by ethylene vinyl alcohol copolymer(EVAL), one showed abscess formation in embolized kidney. The other 4 allowed to perform further pathologic study: within a week after embolization there was no any specific change in vessels, however, minimal endothelial hypertrophy was observed following 2 weeks of embolization. Of the 8 renal arteries embolized by N-buthyl-2-cyanoacrylate(Histoacryl), 4 showed total occlusion of the main renal arteries as well as renal infarction, which reflects the strong adhesiveness of Histoacryl to vascular wall. The other 4 showed fibrinoid degeneration in vascular wall within a week. However, further change was not observed thereafter. In all the 5 renal arteries embolized by polyvinyl alcohol(Ivalon), there were infiltration of inflammatory cells along the vessel walls, within one week, which represents vasculitis. They showed some fibrosis with appearance of giant cells in the vessel wall two weeks after embolization and also showed marked fibrosis of connective tissues surrounding vessels two months after embolization, respectively. The results suggest that EVAL is useful for the embolization of hypervascular lesion with limited arteriovenous fistula, Histoacryl for the curative treatment of the lesion with high blood flow or severe arteriovenous fistula, and Ivalan for palliative treatment of malignant tumor or arteriovenous malformation, respectively.

  • PDF

A Study on STR Analysis According to the Method of Developing Latent Fngerprints Deposited on Non-Porous Surfaces in the Marine Environment (해양환경 내 비다공성 표면에 유류된 잠재지문 현출방법에 따른 STR 분석 연구)

  • Kim, Jin-Sun;Kim, Sea-In;Yoon, Hyun-Kyoung;Choo, Min-kyu
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.10
    • /
    • pp.733-741
    • /
    • 2022
  • Among the various evidence found in maritime crimes, fingerprints and DNA are very important in that they can identify a suspect. In this study, 5 types of non-porous surfaces (plastic, stainless, glass, ceramic, FRP), which are often found as evidence in the actual marine environment, were selected, and latent and blood fingerprints were passed down and immersed at the Donghae Maritime Police Station's exclusive pier for about 7 days. After that, DNA extraction, quantification, and STR profile were analyzed after fingerprint developing CA fumming method and 4 powder methods (Swedish black powder, Concentrated black powder, Supranano red powder, Dazzle orange powder). Among the fingerprint developing methods, when Supranano red powder was applied, a relatively high amount of DNA was found. As a result of STR profile analysis, an average of 16.8 to 9 loci were secured, and all 20 were confirmed in glass and ceramic materials. As a result of the study, it was possible to secure the STR profile by extracting and quantifying DNA after applying the fingerprint developing method to virtual evidence immersed for about 7 days, and further research is needed to secure the STR profile by analyzing DNA after applying various fingerprint developing methods such as VMD and SPR.

Successful Transcatheter Arterial Embolization following Diverticular Bleeding in the Third Portion of the Duodenum: A Case Report (경동맥 색전술을 이용한 십이지장 3부 게실 출혈의 성공적인 지혈: 증례 보고)

  • Seok Jin Hong;Sang Min Lee;Ho Cheol Choi;Jung Ho Won;Jae Boem Na;Ji Eun Kim;Hye Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.237-243
    • /
    • 2021
  • This is a rare case of a 73-year-old male patient who presented with hematochezia and was treated using transcatheter arterial embolization following upper gastrointestinal bleeding in the third portion of the duodenum. The cause of the bleeding was not found on gastrointestinal endoscopy and CT. On the third day of hospitalization, the hemoglobin level continued to decrease. A technetium-99m-labeled red blood cell scan revealed suspicious bleeding in the diverticulum of the third portion of the duodenum. Superior mesenteric artery angiography showed active bleeding from the posteroinferior pancreaticoduodenal artery, which was embolized with N-butyl cyanoacrylate. The patient was discharged on the seventh day after embolization without re-bleeding or complication. We report a rare case of a patient with active bleeding from a duodenal diverticulum that was difficult to diagnose using routine modalities. Herein, we report a rare case of a patient with active bleeding from a duodenal diverticulum that was difficult to diagnose using routine modalities. We also conducted a relavant literature review.