• Title/Summary/Keyword: cutoff time

Search Result 182, Processing Time 0.024 seconds

Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers (Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

Si-core/SiGe-shell channel nanowire FET for sub-10-nm logic technology in the THz regime

  • Yu, Eunseon;Son, Baegmo;Kam, Byungmin;Joh, Yong Sang;Park, Sangjoon;Lee, Won-Jun;Jung, Jongwan;Cho, Seongjae
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.829-837
    • /
    • 2019
  • The p-type nanowire field-effect transistor (FET) with a SiGe shell channel on a Si core is optimally designed and characterized using in-depth technology computer-aided design (TCAD) with quantum models for sub-10-nm advanced logic technology. SiGe is adopted as the material for the ultrathin shell channel owing to its two primary merits of high hole mobility and strong Si compatibility. The SiGe shell can effectively confine the hole because of the large valence-band offset (VBO) between the Si core and the SiGe channel arranged in the radial direction. The proposed device is optimized in terms of the Ge shell channel thickness, Ge fraction in the SiGe channel, and the channel length (Lg) by examining a set of primary DC and AC parameters. The cutoff frequency (fT) and maximum oscillation frequency (fmax) of the proposed device were determined to be 440.0 and 753.9 GHz when Lg is 5 nm, respectively, with an intrinsic delay time (τ) of 3.14 ps. The proposed SiGe-shell channel p-type nanowire FET has demonstrated a strong potential for low-power and high-speed applications in 10-nm-and-beyond complementary metal-oxide-semiconductor (CMOS) technology.

Extraction of Concrete Slab Surface Cracks using Fuzzy Inference and SOM Algorithm (퍼지 추론 기법과 SOM 알고리즘을 이용한 콘크리트 슬래브 표면의 균열 추출)

  • Kim, Kwang-Baek
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.38-43
    • /
    • 2012
  • It is necessary to measure cracks on concrete slab surface accurately in concrete structure maintenance for the stability of the structure. However, in real world, the process is done by time consuming and ineffective manual inspection. Although there have been some studies to provide computerized inspection methods, they are vulnerable to rugged surface or noise due to the influence of the light or environmental reasons. In this paper, we propose a new method that extracts not only undistorted cracks but minute cracks that were often regarded as noise. We extract candidate crack areas by applying fuzzy method with R, G, and B channel values of concrete slab structure. Then further refinement processes are performed with SOM algorithm and density based cutoff to remove noise. Experiment verifies that the proposed method is sufficiently useful in various crack images.

Smart Outlet System for Single-person Household based on IoT (Internet of Things) (사물 인터넷 기반의 1인 가구를 위한 스마트 콘센트 시스템)

  • Kim, Hye-Suk;Park, Byeong-Ju;Cho, Young-Ju
    • Journal of Digital Contents Society
    • /
    • v.18 no.5
    • /
    • pp.895-904
    • /
    • 2017
  • In this paper, we propose an IoT based smart outlet system for one-person household with electric safety, electric energy consumption management and transmission of messages to the reserved contacts by connecting the emergency network. The proposed smart outlet system is implemented by parsing packet data and protocol between server, module, application and WiFi AP receiver. The WiFi AP built for communication can be used not only for the outlet but also for the gas barrier, the door lock and the like. In addition, the proposed method can provide the remote monitoring function by receiving the amount of power of the receptacle received through the AC current sensor (SCT-013) in real time. The smart outlet system is expected to be capable of automatically shutting off the power in case of emergency through automatic power use analysis in addition to the standby power cutoff function.

Validation of Adult Fall Assessment Scale Korean Version for Adult Patients in General Hospitals in Korea (한국형 낙상 위험 사정도구의 타당성 평가연구)

  • Choi, Eun Hee;Ko, Mi Suk;Lee, Shin Ae;Park, Jung Ha
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.265-273
    • /
    • 2020
  • Purpose: The purpose of this study was to test the predictive validity of the Fall Assessment Scale-Korean version (FAS-K) and to find the most appropriate cutoff score to screen high-risk fall groups in adult patients in general hospitals in Korea. Methods: We performed a prospective evaluation study in medical and surgical ward patients at two major general hospitals in Seoul. Data were collected from Nov. 1, 2018 to Feb. 28, 2019, nurses performed 651 observation series. The researcher measured the fall risk assessment score by applying FAS-K, MFS (Morse Fall Scale), and JHFRAT (Johns Hopkins Hospital Fall Risk Assessment tool) to the patients twice a week between 10 am and 12 noon. Data were analyzed using Pearson's corelation coefficients, and the sensitivity, specificity, predictive value, and the area under the curve (AUC) of the three tools. Results: The FAS-K was positively correlated with the MFS (r=.70, p<.001) and the JHFRAT (r=.82, p<.001). According to the receiver operating characteristics (ROC) curve analysis of the FAS-K, sensitivity, specificity, and positive and negative prediction values were 85.3%, 49.4%, 8.5%, and 98.4%, respectively, when the FAS-K score was 4. Therefore, the cut-off score of the FAS-K to identify groups with high fall risk was 4. Conclusion: The FAS-K is a valid tool for measuring fall risk in adult inpatients. In addition, the FAS-K score, 4, can be used to identify high-risk fall groups and know specific points in time to provide active interventions to prevent falls.

Comparative analysis of noise from three Falcon 9 launches (Falcon 9 로켓 3회 발사 소음의 비교 분석)

  • Mathews, Logan T.;Gee, Kent L.;Hart, Grant W.;Rasband, Reese D.;Novakovich, Daniel J.;Irarrazabal, Francisco I.;Vaughn, Aaron B.;Nelson, Pauline
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.4
    • /
    • pp.322-330
    • /
    • 2020
  • This study investigates the far-field noise from three Falcon 9 vehicle launches from Vandenberg Air Force Base, CA, USA, as measured from the same location within the nearby community of Lompoc. The overall sound pressure levels for the three launches are shown to be similar, but some differences in the early launch period are thought to be weather-related. The peak directivity angle in overall level is approximately 65 deg, which is consistent with horizontally-fired, static rocket data. For the third launch, waveforms and spectra are analyzed for different events during the launch sequence. The measured spectral bandwidth decreases with time, but spectral levels remain above the ambient noise throughout the main-engine firing. Additionally, late-launch phenomena observed in the data appear to be correlated with main-engine cutoff and second-stage engine start.

Long-term outcomes after stent insertion in patients with early and late hepatic vein outflow obstruction after living donor liver transplantation

  • Kim, Kyeong Sik;Lee, Ji Soo;Choi, Gyu Sung;Kwon, Choon Hyuck David;Cho, Jae-Won;Lee, Suk-Koo;Park, Kwang Bo;Cho, Sung Ki;Shin, Sung Wook;Kim, Jong Man
    • Annals of Surgical Treatment and Research
    • /
    • v.95 no.6
    • /
    • pp.333-339
    • /
    • 2018
  • Purpose: The purpose of this study was to describe the long-term effects of stenting in patients with hepatic venous outflow obstruction (HVOO), who underwent living donor liver transplantation (LDLT). Methods: Between January 2000 and December 2009, 622 adult patients underwent LDLT at our hospital, and of these patients, 21 (3.3%) were diagnosed with HVOO; among these patients, 17 underwent stenting. The patients were divided into early or late groups according to the time of their HVOO diagnoses (cutoff: 60 days after liver transplantation). Results: The median follow-up period was 54.2 months (range, 0.5-192.4 months). Stent insertion was successful in 8 of 10 patients in the early group and 6 of 7 in the late group. The 5-year primary patency rates were 46% and 20%, respectively. In both groups, patients with recurrent HVOO at the beginning showed kinking confirmed by venography. Patients who carried their stents for more than 3 years maintained long-term patency. There was no significant difference in spleen size between groups; however, when the groups were compared according to whether they maintained patency, spleens tended to be smaller in the patency-maintained group. Conclusion: Unlike stenosis, if kinking is confirmed on venography, stenting is not feasible in the long term for patients with LDLT.

Derivation of Flexural Rigidity Formula for Two-row Overlap Pile Wall (2열 겹침주열말뚝의 휨 강성 산정식 유도)

  • Choi, Wonhyuk;Kim, Bumjoo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.109-118
    • /
    • 2018
  • Two-row overlap pile wall, currently under development for use in deep excavations, is a novel retaining structure designed to perform itself as a cutoff wall as well as a high-stiffness wall by constructing four overlapping piles arranged in zigzag manner at a time using a tetra-axis auger. This wall has a relatively complex cross-section, compared with other types of pile wall, which would make it difficult to determine design parameters related to cross-section. In this study, a flexural rigidity equation has been derived by analyzing both theoretically and statistically various wall cross-sections with different pile diameters and overlap lengths. The flexural rigidity equation was found to show the maximum error rate of 3%.

Albumin-Bilirubin Score Predicts Tolerability to Adjuvant S-1 Monotherapy after Curative Gastrectomy

  • Miwa, Takashi;Kanda, Mitsuro;Tanaka, Chie;Kobayashi, Daisuke;Hayashi, Masamichi;Yamada, Suguru;Nakayama, Goro;Koike, Masahiko;Kodera, Yasuhiro
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.183-192
    • /
    • 2019
  • Purpose: Due to adverse events, dose reduction or withdrawal of adjuvant chemotherapy is required for some patients. To identify the predictive factors for tolerability to postoperative adjuvant S-1 monotherapy in gastric cancer (GC) patients, we evaluated the predictive values of blood indicators. Materials and Methods: We analyzed 98 patients with pStage II/III GC who underwent postoperative adjuvant S-1 monotherapy. We retrospectively analyzed correlations between 14 parameters obtained from perioperative routine blood tests to assess their influence on the withdrawal of postoperative adjuvant S-1 monotherapy, within 6 months after discontinuation. Results: Postoperative adjuvant chemotherapy was discontinued in 21 patients (21.4%) within 6 months. Univariable analysis revealed that high preoperative albumin-bilirubin (ALBI) scores had the highest odds ratio (OR) for predicting the failure of adjuvant S-1 chemotherapy (OR, 6.47; 95% confidence interval [CI], 2.08-20.1; cutoff value, -2.696). The high ALBI group had a significantly shorter time to failure of postoperative adjuvant S-1monotherapy (hazard ratio, 3.48; 95% CI, 1.69-7.25; P=0.001). Multivariable analysis identified high preoperative ALBI score as an independent prognostic factor for tolerability (OR, 10.3; 95% CI, 2.33-45.8; P=0.002). Conclusions: Preoperative ALBI shows promise as an indicator associated with the tolerability of adjuvant S-1 monotherapy in patients with pStage II/III GC.

Gaps-In-Noise Test Performance in Children with Speech Sound Disorder and Cognitive Difficulty

  • Jung, Yu Kyung;Lee, Jae Hee
    • Journal of Audiology & Otology
    • /
    • v.24 no.3
    • /
    • pp.133-139
    • /
    • 2020
  • Background and Objectives: The Gaps-In-Noise (GIN) test is a clinically effective measure of the integrity of the central auditory nervous system. The GIN procedure can be applied to a pediatric population above 7 years of age. The present study conducted the GIN test to compare the abilities of auditory temporal resolution among typically developing children, children with speech sound disorder (SSD), and children with cognitive difficulty (CD). Subjects and Methods: Children aged 8 to 11 years-(total n=30) participated in this study. There were 10 children in each of the following three groups: typically developing children, children with SSD, and children with CD. The Urimal Test of Articulation and Phonology was conducted as a clinical assessment of the children's articulation and phonology. The Korean version of the Wechsler Intelligence Scale for Children-III (K-WISC-III) was administered as a screening test for general cognitive function. According to the procedure of Musiek, the pre-recorded stimuli of the GIN test were presented at 50 dB SL. The results were scored by the approximated threshold and the overall percent correct score (%). Results: All the typically developing children had normal auditory temporal resolution based on the clinical cutoff criteria of the GIN test. The children with SSD or CD had significantly reduced gap detection performance compared to age-matched typically developing children. The children's intelligence score measured by the K-WISC-III test explained 37% of the variance in the percent-correct score. Conclusions: Children with SSD or CD exhibited poorer ability to resolve rapid temporal acoustic cues over time compared to the age-matched typically developing children. The ability to detect a brief temporal gap embedded in a stimulus may be related to the general cognitive ability or phonological processing.