• Title/Summary/Keyword: cutoff time

Search Result 182, Processing Time 0.026 seconds

Non-contact Ultrasonic Technique for the Evaluation Wall Thinning of the Plate (박판의 두께감육 평가를 위한 비접촉 유도초음파 검사 기법)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Tae-Hyung;Kim, Yong-Kwon;Cho, Yong-Sang;Song, Won-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.287-293
    • /
    • 2005
  • Ultrasonic guided waves are gaining increasing attention for the inspection of platelike and rodlike structures. At the same time, inspection methods that do not require contact with the test piece are being developed for advanced applications. This paper capitalizes on recent advances in the areas of guided wave ultrasonics and noncontact ultrasonics to demonstrate a superior method for the nondestructive detection of defects thinning simulating hidden corrosion in thin aluminum plates. The proposed approach uses EMAT(electro-magnetic acoustic transducer) for the noncontact generation and detection of guided waves. Interesting features in the dispersive behavior of selected guided modes are used for the detection of plate thinning. It is shown that mode cutoff measurements provide a qualitative detection of defects thinning. Measurement of the mode group velocity can be also used to quantify depth thinning.

Is It Possible to Predict the Iron Status from an Infant's Diet History?

  • Kim, Hyung Jin;Kim, Dong Hyun;Lee, Ji Eun;Kwon, Young Se;Jun, Yong Hoon;Hong, Young Jin;Kim, Soon Ki
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.2
    • /
    • pp.95-103
    • /
    • 2013
  • Purpose: Iron deficiency remains a very common nutritional problem despite the improvement in nutrition and increased understanding of methods for its prevention. Thus, we try to create a new method for screening iron nutrition through infant nutrition history. Methods: Among the children who visited Inha University Hospital from March 2006 to July 2012, 181 children with iron deficiency anemia (IDA) and 52 children without IDA ranging from 6 to 36 months of age were reviewed in this study. We used the age when they began to wean food, the type of sort weaning foods, the time required for successful weaning, iron content in weaning foods, and the duration of breastfeeding for scoring infant nutrition history based on a questionnaire. Results: The mean score of the IDA group was $7.8{\pm}2.6$ points, which was significantly higher than that of the control group ($5.6{\pm}2.1$) (p=0.000). If we set up the cutoff value at 6 points, this screening has 86.8% sensitivity and 36% specificity. In addition, as the IDA score increased, there was a falling trend of hemoglobin. Conclusion: The IDA score does not have high specificity or high sensitivity. However, this study conveys that those patients who record a high score have low hemoglobin. Therefore, we suggest this score system for screening more IDA patients via nonpainful techniques.

C-reactive protein and N-terminal pro-brain natriuretic peptide discrepancy: a differentiation of adenoviral pharyngoconjunctival fever from Kawasaki disease

  • Choi, Jung Eun;Kang, Hee Won;Hong, Young Mi;Sohn, Sejung
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.1
    • /
    • pp.12-16
    • /
    • 2018
  • Purpose: To differentiate adenoviral pharyngoconjunctival fever (PCF) from acute Kawasaki disease (KD) using laboratory tests before results of virus-real time polymerase chain reaction and ophthalmologic examination are obtained. Methods: Baseline patient characteristics and laboratory measurements were compared between 40 patients with adenovirus infection and 123 patients with KD. Results: The patients with adenovirus infection were generally older than those with KD (median: 3.9 years vs. 2 years, P=0.000). White blood cell and, platelet count, and aspartate aminotransferase, alanine aminotransferase, and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels showed significant differences between the 2 groups, but the C-reactive protein (CRP) levels did not ($6.8{\pm}3.0mg/dL$ vs. $8.3{\pm}5.8mg/dL$, P=0.126). In the adenovirus infection group, the CRP levels were <1, <3, <10, and ${\geq}10mg/dL$ in 2 (5%), 3 (7.5%), 30 (75%), and 5 patients (12.5%), respectively. The cutoff NT-proBNP level was 265 pg/mL. Discrepancy was defined as CRP and NT-proBNP levels of ${\geq}3$ or <3 mg/dL, and <265 or ${\geq}265pg/mL$, respectively. Among the 35 patients with adenovirus infection whose CRP levels were ${\geq}3mg/dL$, 29 (82.9%) showed a discrepancy. Conversely, of the 103 patients with KD whose CRP levels were ${\geq}3mg/dL$, 83 (80.6%) showed no discrepancy. Between the groups, a significant difference in discrepancy rate was observed (P=0.000). None of the patients with adenovirus infection had CRP and NT-proBNP levels of <3 mg/dL and ${\geq}265pg/mL$, respectively. Conclusion: With a sensitivity of 82.9% and a specificity of 80.6%, CRP and NT-proBNP levels may differentiate between adenoviral PCF and acute KD.

3-Dimensional Analysis of the Running Motion in the Max-Velocity Phase and the Fatigue Phase During 400m Sprint by Performed Elementary School Athletes (달리기시 최고 속도 및 피로 구간의 3차원 동작 분석)

  • Bae, Sung-Jee
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.115-124
    • /
    • 2006
  • This study was conducted to investigate the running motion in the max-velocity phase(150-160m) and the fatigue phase(350-360m) during 400m sprint by performed elementary school athletes. Eighteen elementary school male athletes who achieved at least the 3rd place in the sprint at the Korea Gangwon-Do elementary school track and field meetings during 2004 and 2005 were selected as subjects. The running motions performed by the subjects were recorded using two 8mm high speed cameras at the nominal speed of 100 frames per second. The Direct Linear Transformation technique was adopted from the beginning of filming to the final stage of data extraction. KWON 3D motion analysis package program was used to compute the 3 Dimensional coordinates, smoothing factor in which lowpass filtering method was used and cutoff frequency was 6.0 Hz. The movement patterns during foot touchdown and takeoff for the running stride were related with the biomechanical consideration. Within the limitations of this study it is concluded: In order to increase running velocity, several conditions must be fullfilled at the instant of leg touchdown and takeoff during the fatigue phase(350-360m). First, the body C.O.G(Center of Gravity) height should be raised at the instant of leg touchdown and takeoff during the fatigue phase. Second, the foot contact time should be shortened and the takeoff distance should be increased at the foot takeoff during the fatigue phase. Third, the shank angular velocity with respect to a transverse axis through the center of gravity should be increased during the leg touchdown and takeoff in the fatigue phase. Forth, the active landing style described as clawing the ground with the sole of the foot should be performed during the leg touchdown and takeoff in the fatigue phase) phase. Fifth, In order to increase running velocity in the fatigue phase while taking a slightly greater leg knee angle and body lean angle within the range of the subject's running motion during the fatigue phase would result in greater flight distance.

Functional Movement Screen as a Predictor of Occupational Injury Among Denver Firefighters

  • Shore, Erin;Dally, Miranda;Brooks, Shawn;Ostendorf, Danielle;Newman, Madeline;Newman, Lee
    • Safety and Health at Work
    • /
    • v.11 no.3
    • /
    • pp.301-306
    • /
    • 2020
  • Background: The Functional Movement Screen (FMSTM) is a screening tool used to assess an individual's ability to perform fundamental movements that are necessary to do physically active tasks. The purpose of this study was to assess the ability of FMS to predict occupational injury among Denver Fire Department firefighters. Method: FMS tests were administered from 2012 to 2016. Claim status was defined as any claim occurrence vs. no claim and an overexertion vs. no claim/other claim within 1 year of the FMS. To assess associations between FMS score and claim status, FMS scores were dichotomized into ≤ 14 and > 14. Age-adjusted odds ratios were calculated using logistic regression. Sensitivities and specificities of FMS predicting claims at various FMS score cut points, ranging from 10 to 20 were tested. Results: Of 581 firefighters (mean ± SD, age 38 ± 9.8 y) who completed FMS between February 2015 and March 2018, 188 (32.4%) filed a WC claim in the study time frame. Seventy-two of those (38.3%) were categorized as overexertion claims. There was no association between FMS score and claim status [odds ratio (OR) = 1.27, 95% confidence interval (CI): 0.88 - 1.83] and overexertion claim vs. no claim/other claim (OR = 1.33, 95% CI: 0.81 - 2.21). There was no optimal cutoff for FMS in predicting a WC claim. Conclusions: Although the FMS has been predictive of injuries in other populations, among this sample of firefighters, it was not predictive of a future WC claim.

Serum Pleiotrophin Could Be an Early Indicator for Diagnosis and Prognosis of Non-Small Cell Lung Cancer

  • Du, Zi-Yan;Shi, Min-Hua;Ji, Cheng-Hong;Yu, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1421-1425
    • /
    • 2015
  • Aims: Pleiotrophin (PTN), an angiogenic factor, is associated with various types of cancer, including lung cancer. Our aim was to investigate the possibility of using serum PTN as an early indicator regarding disease diagnosis, classification and prognosis, for patients with non-small cell lung cancer (NSCLC). Methods: Significant differences among PTN levels in patients with small cell lung cancer (SCLC, n=40), NSCLC (n=136), and control subjects with benign pulmonary lesions (n=21), as well as patients with different pathological subtypes of NSCLC were observed. Results: A serum level of PTN of 300.1 ng/ml, was determined as the cutoff value differentiating lung cancer patients and controls, with a sensitivity and specificity of 78.4% and 66.7%, respectively. Negative correlations between serum PTN level and pathological differentiation level, stage, and survival time were observed in our cohort of patients with NSCLC. In addition, specific elevation of PTN levels in pulmonary tissue in and around NSCLC lesions in comparison to normal pulmonary tissue obtained from the same subjects was also observed (n=2). Conclusion: This study suggests that the serum PTN level of patients with NSCLC could be an early indicator for diagnosis and prognosis. This conclusion should be further assessed in randomized clinical trials.

The Telemetry Transmitter with Variable Data rate Transmission (가변 데이터 전송 가능한 텔레메트리(Telemetry) 송신기)

  • Kim, Jang-Hee;Hong, Seung-Hyun;Park, Byong-Kwan;Kim, Bok-ki;Kim, Hyo-Jong
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • In this paper, We have studied the structure of a Telemetry Transmitter capable of transmitting variable data rates. This paper proposed a structure combining variable pre-modulation filter with cutoff characteristic with variable input sample rate converter. Variable pre-modulation filter has the same characteristics as pre-modulation filter and is converted to a constant sampling rate without structural changes according to the variable input data rate. We propose a software program that actively controls variable pre-modulation filter and variable input sample rate converter to respond to real-time changing data.

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF

Detection and characterization of Clostridium difficile infections tracking the trends of Clostridium difficile culture

  • Ock, Min-Su;Oh, Jin-Sun;Kim, Hwa-Jung;Lyu, Yong-Man;Lee, Moo-Song
    • Quality Improvement in Health Care
    • /
    • v.22 no.2
    • /
    • pp.15-25
    • /
    • 2016
  • Objectives: In this study, we examined the validity of Clostridium difficile culture results as a proxy measure of Clostridium difficile infection, and inferred the epidemiologic characteristics of Clostridium difficile infection by tracking the trends of Clostridium difficile culture results. Methods: We reviewed the medical records to figure out the actual possibilities of Clostridium difficile infection of those with positive or negative results of Clostridium difficile culture during the time span from January 2012 to March 2012. We calculated the positive and negative predictive value of Clostridium difficile culture results for Clostridium difficile infection. Furthermore, epidemiologic characteristics of Clostridium difficile infection in a tertiary general hospital in 2012 were analyzed. Result: The estimated positive predictive value of Clostridium difficile culture tests for Clostridium difficile infection was 100%, and the estimated negative predictive value was around 94.4~99.3% depending on the cutoff value of possibility of Clostridium difficile infection. A total of 622 cases were identified as Clostridium difficile infection in a tertiary general hospital in 2012 and there were 4.9 patients with Clostridium difficile infection per 1,000 inpatients. Conclusion: In conclusion, we identified that Clostridium difficile culture results can be used as a proxy measure of Clostridium difficile infection.

Comparison of Kinematic Variables of the Elite Woman's 100m Hurdler (엘리트 여자 100m 허들선수들의 운동학적 변인 비교)

  • Ryu, Jae-Kyun;Chang, Jae-Kwan;Yeo, Hong-Chul;Lim, Jung-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.149-156
    • /
    • 2007
  • The purpose of this study was to compare the world class women's hurdlers with kinematic variables Lee Yeon-Kyoung's in the 100m hurdle. Among korea elite female hurdler, Lee Yeon-Kyoung was participated as a subject. Eight JVC video cameras(GR-HD1KR) were used to film the performance of Lee Yeon-Kyoung at a frame rate of 60fields/s. The real-life three-dimensional coordinate data of digitized body landmarks were smoothed using a fourth order Butterworth low pass recursive digital filter with an estimated optimum cutoff frequency of 7.4Hz. After analyzing and comparing Lee Yeon Kyung's kinematic variables with the world top class hurdlers in the woman's 100m hurdle run, the following conclusions were obtained. 1. Lee should be able to increase the speed with over 5.4m/s from start to first hurdle and then maintain the speed range from 8.33m/s to 8.67m/s until 10th hurdle. Lee should have to maintain the speed with 8.51m/s from 10th hurdle to finish line. 2. Lee has to reach her maximum running speed at 5th hurdle and then has to shorten running time with 0.5sec between hurdles. 3. Lee should be able to run around 2.5sec from start to frist hurdle and then maintain under 1.00sec following phases. Lee should be able to maintain under 1.10sec from 10th hurdle to finish line. 4. Lee needs to control a consistent takeoff and landing distance pattern, Lee needs to lower the height of the center of gravity of the body with 0.33m when she clears the hurdles.